• Facebook
  • Linkedin
  • Youtube
  • Twitter
packaging testing equipment Water Vapor Permeation Tester
News
  •  GBPI Face Mask Air Flow Resistance and Differential Pressure Tester
    GBPI Face Mask Air Flow Resistance and Differential Pressure Tester 2020-07-08
    Application Medical mask testing Textile material testing Laboratory related tests Standard EN 14683 Functional advantages Built-in touch screen and micro printer High-precision differential pressure sensor, digitally displays the differential pressure across the sample Manual control of air flow and time Pressure sensor, gas quality controller can be calibrated and measured Theoretical method The output of the air flow is set by a gas flow meter, the air flow passes through a certain area of the test sample, the current pressure is detected by a pressure sensor, and the pressure difference is calculated. Technical index Item Technical Parameter Pressure Sensor Range 0~500Pa Pressure Sensor Accuracy ±0.5% F.S Air Flow Rrange 1 ~ 10L/min(Standard 8L/min) Air Flow Accuracy ±1.0% F.S Gas Source Compressed Air Air Pressure ≥0.3MPa Dimensions 350mm×260mm×360mm Weight 20kg Power Supply AC220V, 50HZ For more discount information on mask testing instruments, you can call 13539758284 or contact email: info@gbtest.cn
    View More
  • Surgical Face Masks and General-Use Masks testing
    Surgical Face Masks and General-Use Masks testing 2020-03-27
    GBPI offers a comprehensive set of testing machine for surgical face masks and general-use medical masks. These tests are essential to ensuring performance properties are validated to support marketing label claims and to classify these mask types. For CE marking submissions, additional tests may be required depending on label claims. Summary of face mask testers Bacterial Filtration Efficiency (BFE) Differential Pressure Particle filtration efficiency Synthetic blood fluid penetration resistance for face masks Ethylene Oxide (EO) Residual Testing Face Mask Respiratory resistance testing mask elastic band testing Flammability test click to see GBPI face mask testers Applicable Standards ASTM 2100 EN 14683 NIOSH ISO 10993 Study Outline Bacterial Filtration Efficiency (BFE) The Bacterial Filtration Efficiency test determines the filtration efficiency by comparing the bacterial control counts to test article effluent counts. The test is conducted using Staphylococcus aureus as the challenge organism. After the filtration media is preconditioned, a liquid suspension of S. aureus is aerosolized and delivered to the filtration media at a constant flow rate of 28.3 liters per minute (LPM) or 1 cubic foot per minute (CFM). The aerosol droplets are drawn through a six-stage Andersen sampler for collection. The number of bacterial aerosol droplets contacting the filter media is determined by conducting challenge controls without filter medium in the test system. Challenge controls are maintained at 1700 – 3000 colony-forming units (CFU) with a mean particle size (MPS) of 3.0 ± 0.3 µm. This allows filtration efficiencies to be reported up to >99.9%. Click to see the Principle of BFE tester Particle Filtration Efficiency (PFE) The Particle Filtration Efficiency (PFE) test evaluates the nonviable particle retention or filtration efficiency of filter media and other filtration devices at sub-micron levels. This test is performed on face masks and all filter material that allows 1 cubic foot per minute (CFM) flow to pass through it. Also referred to as Latex Particle Challenge, this test is required for ASTM F2100 and is performed according to the ASTM F2100 and follows the basic principle of ASTM F2299. Applicable Standards ASTM F2100 ASTM F2299 more details of Particle filtration efficiency tester Synthetic Blood Penetration for Liquid Barriers The Synthetic Blood Penetration – Splash Resistance test is one of two synthetic blood resistance tests to determine a product’s ability to act as a barrier to blood-borne pathogens. The Splash Resistance test method challenges medical face masks with a fixed volume of synthetic blood directed at high velocity at the center of the mask. This test is required by ASTM F2100 and is tested in compliance with ASTM F1862, ASTM F2100, EN 14683, and ISO 26609. Applicable Standards ASTM F1862 ISO 22609 ASTM F2100 EN 14683 more details of mask Resistance against Penetration tester Flammability Test: The Flammability test proc...
    View More
  • Bacterial Filtration Efficiency (BFE)
    Bacterial Filtration Efficiency (BFE) 2020-03-27
    The Bacterial Filtration Efficiency (BFE) test is performed on filtration materials and devices that are designed to provide protection against biological aerosols, such as face masks, surgical gowns, caps, and air filters. This test is used for FDA 510(k) submissions for surgical masks, is required by ASTM F2100 and EN 14683, and complies with ASTM F2101 and EN14683. Click to view BFE tester Applicable Standards · ASTM F2100 · EN 14683 · ASTM F2101 Study Outline Bacterial Filtration Efficiency (BFE) The Bacterial Filtration Efficiency test determines the filtration efficiency by comparing the bacterial control counts to test article effluent counts. The test is conducted using Staphylococcus aureus as the challenge organism. After the filtration media is preconditioned, a liquid suspension of S. aureus is aerosolized and delivered to the filtration media at a constant flow rate of 28.3 liters per minute (LPM) or 1 cubic foot per minute (CFM). The aerosol droplets are drawn through a six-stage Andersen sampler for collection. The number of bacterial aerosol droplets contacting the filter media is determined by conducting challenge controls without filter medium in the test system. Challenge controls are maintained at 1700 – 3000 colony-forming units (CFU) with a mean particle size (MPS) of 3.0 ± 0.3 µm. This allows filtration efficiencies to be reported up to >99.9%. The BFE test offers a number of advantages over other filtration efficiency tests. It has been used with little or no modification for years and provides a standard reference for comparison of filtration materials. The mean particle size can be tightly controlled and is sized using a six-stage viable-particle Andersen sampler, permitting stage-by-stage analysis. The BFE procedure is reproducible, and provides a more severe challenge to most filtration devices than would be expected in normal use. Large numbers of material can be evaluated in a relatively short time. BFE testing is commonly performed along with the Differential Pressure (Delta P) test. For housed filters, we recommend the Increased Challenge method. This procedure uses a higher concentration of challenge to be delivered to each test material. Filtration efficiency measurements can be determined up to >99.9999%. Increased Challenge Bacterial Filtration Efficiency (BFE) The Increased Bacterial Filtration Efficiency test determines the filtration efficiency by comparing the bacterial control counts to test article effluent counts. The test is conducted using Staphylococcus aureus as the challenge organism. A liquid suspension of S. aureus is aerosolized and delivered to the filtration media at a constant flow rate of 30 liters per minute (LPM). The aerosol droplets are collected in all-glass impingers (AGIs) in parallel. The challenge is delivered for a one-minute interval and sampling through the AGIs is conducted for two minutes to clear the aerosol chamber. The titer of the assay fluid is det...
    View More
  • Protective products supply information
    Protective products supply information 2020-03-22
    Dear customers, The following is the protective products  information collected by GBPI for you. Please contact us if necessary. Mob: +86 135 3975 8284 Tel: +86 20 86153790 Email: info@gbtest.cn Website: www.gbpitester.com
    View More
  • GBPI Helps Global CORONA VIRUS Prevention and Control
    GBPI Helps Global CORONA VIRUS Prevention and Control 2020-03-20
    Currently, CORONA VIRUS continues to rag around the world. At the time when the international community is stepping up its control of the epidemic, China is actively sharing its prevention and control experience with relevant countries, and is providing assistance within its capacity to some countries where the epidemic has spread. As an industry-leading high-tech private enterprise. GBPI, in addition to expediting the development and production of mask detection equipment, is facing the global epidemic, and we hope to provide assistance to global enterprises and friends wherever we can, specifically in the following areas: 1.Provided by direct sales or sales channels of protective equipment Mask, Goggles, Protective Clothing, Infrared Forehead Grab, Portable Ventilator 2. Guidance for community, enterprise and individual epidemic prevention and control 1) Communities: how to carry out community prevention and control management, how to carry out epidemic prevention and control propaganda to community members 2) Enterprise companies: how to prevent and control, and what to do if there are suspected cases in the enterprise 3) Personal: how to protect daily, how to protect the surrounding cases 3. Free provision of protective equipment in severe epidemic areas or medical institutions (GBPI will donate) For some severely epidemic-stricken regional institutions or communities, a certain number of protective supplies are provided free of charge. Friends in need can contact us. 4. Mental health guidance during the epidemic How companies can channel the bad emotions of employees during the epidemic, try not to affect the operation of the enterprise, and for employees, how to face the epidemic with a healthy mentality. 5.GBPI Self-developed Mask Detection Instrument Ethylene oxide gas chromatography Mask Synthetic Blood Penetration Mobile Atomizing Humidification And Disinfection Equipment Multifunctional Tensile Tester for Face Mask Face Mask Particulate Filtration Efficiency Tester Face Mask Pressure Differential Tester Respiratory resistance tester Mask Bacterial Filtration Efficiency (BFE) Detector Facial Mask Flame Retardant Tester Friends who need help around the world can contact us and we will try our best to help you! Factory Add: No.1 Minghua 3 St. Jinxiu Rd., Economic Development Zone, Guangzhou, 510730 China Office Add: Room 305, Science building, Guangdong University of Technology, Higher mega education center, Panyu, Guanghzou, 510006 China Tel: +86 20 86153790 Hotline: +86 400-7886855 Fax: +86-20-82087405 Email: info@gbtest.cn Website: www.gbpitester.com
    View More
first page 11 12 13 14 15 16 17 18 19 20 last page

A total of 20 pages

Contact Us

Call Us : 13539758284

Email Us : info@gbtest.cn

Address : No.1 Minghua 3 St. Jinxiu RD., Economic Development Zone, Guangzhou 510730, China

Send A Message

Leave us a message, we will get back to you ASAP.

  • Facebook
  • Linkedin
  • Youtube
  • Twitter

Copyright @ 2024 Guangzhou Biaoji Packaging Equipment Co.,Ltd. All Rights Reserved.

Chat now

Inquiry Now

Home

Products

News

contact