packaging testing equipment Water Vapor Permeation Tester
Products
Home /

Barrier And Permeation Properties Test Equipment

/

Gas Permeability Analyzer

/Gas Transmission Rate Tester for Packaging Film

Gas Transmission Rate Tester for Packaging Film

Introduction

The N560 2.0 Gas Transmission Rate Tester is a high-precision laboratory testing equipment integrating machinery, electronics and software. It is suitable for the gas barrier property test of plastic films, composite films, sheets, metal foils and other sheet materials, as well as the gas transmission rate test of packaging containers such as bottles, bags, cans and boxes made of plastics, rubber, paper and other multi-type materials.
 
  • Brand:

    GBPI
  • Item NO.:

    N560 2.0
Inquiry now
Product Detail

Test Principle

The N560 2.0 Gas Transmission Rate Tester is designed based on the principle of the differential pressure method. The treated sample is clamped between the upper and lower test chambers, and a vacuum pump is used to evacuate the entire gas circuit system to a specified vacuum level. Then the test gas at one atmospheric pressure is filled into the upper chamber, forming a constant pressure difference between the upper and lower chambers. Driven by the pressure gradient, the test gas permeates from the upper chamber to the lower chamber through the sample film. The system calculates the gas transmission rate of the tested sample according to the pressure variation in the lower chamber.
Schematic Diagram of Differential Pressure Method

 

Standards

Chinese Pharmacopoeia 2025 Edition <4007> Method for Determination of Gas Transmission Rate of Pharmaceutical Packaging Materials, GB/T 1038.1, ISO 2556, ISO 15105-1, ASTM D1434, JIS K7126-1, YBB 00082003

 

Specifications

Item Technical Parameter
Test Range 0.01~25,000 cm³/(m²·24 h·0.1 MPa)
Resolution 0.0001 cm³/(m²·24 h·0.1 MPa)
Temperature Control Range 15~60℃
Temperature Control Precision ±0.1 ℃
Vacuum Precision ±0.2% of indicated value
Vacuum Degree < 10 Pa
Vacuum Resolution 0.01 Pa
Test Pressure 0.1 MPa
Test Gas O₂, CO₂, N₂, etc.
Effective Test Area 50.24 cm²
Sample Size Φ110 mm
Sample Thickness ≤2 mm
Test Quantity 6 samples
Pneumatic Pressure ≥0.3 MPa
Power 1500 W
Power Supply AC 220V, 50Hz
Overall Dimension 1140mm×600mm×440mm

 

Application

 

Films

Various plastic films (PP/PET/PE/PVC/BOPP/CPP, etc.), plastic composite films, paper-plastic composite films, metal composite films, co-extruded films, aluminized films, degradable packaging films (PLA/PBAT/PBS etc.) and other membranous materials

 

Sheet

Solid medical hard sheet (PP/PVC/PTP, etc.), metal composite sheet, rubber sheet and other sheet materials

 

Paper and cardboard

Coated paper, carbon paper, silicone paper, aluminized paper, paper-aluminum-plastic composite sheet and other paper, cardboard

 

Medicinal patch, warmer patch

Medical plaster treatment patch, warm patch, dysmenorrhea patch, etc.

 

Hygiene

Sanitary napkins, pads and other hygiene products

 

Package

Wine bottles, Coke bottles, peanut oil drums, Tetra Pak packaging, vacuum packaging bags, three-piece cans, cosmetic packaging, toothpaste tubes, jelly cups, yogurt cups, etc. Plastic, rubber, paper, paper-plastic composite, glass, metal bottles Gas transmission rate test of bags, cans, boxes and drums

 

Gases

Oxygen, carbon dioxide, nitrogen, air, helium, etc.

 

 

Send A Message

Leave us a message, we will get back to you ASAP.

Related Products
Gas Permeability Analyzer N500 2.0 Gas Permeability Analyzer
Introduction Based on the test principle of the differential pressure method, N530 is designed with reference to the GB/T 1038 standard and used to test the gas transmission rate (quantity) of film or sheet materials.
Gas Permeability Analyzer N530 L Gas Permeability Analyzer
Introduction Based on the test principle of the differential pressure method, N530L is designed with reference to the GB/T 1038 standard and used to test the gas transmission rate (quantity) of film or sheet materials.
Differential Pressure Gas Transmission Tester Differential Pressure Method Gas Transmission Tester N530 2.0
Introduction N530 2.0 is based on the test principle of differential pressure method, It's designed with reference to GB/T 1038, ISO 2556 and other standards. Adopt high-precision pressure sensor and automatic pressure difference keeping technology, high test accuracy. It is suitable for the gas permeability test of films, sheets, papers, packages and related materials in the fields of food, medicine, medical equipment, daily chemicals, photovoltaic electronics, etc. It provides a wide range and high-efficiency gas transmission rate test of high, medium and low gas barrier materials.
Gas permeation testing Gas Permeability Testing Differential Pressure Method N500L
Product Introduction This product is based on the test principle of the differential pressure method, and is designed and manufactured with reference to ASTM D1434, ISO 2556 and other standards. With high-precision pressure sensor and automatic differential pressure maintaining technology, this machine has high test accuracy. It is suitable for the gas permeability test of films, sheets, paper, packaging and related materials in food, medicine, medical equipment, daily chemicals, photovoltaic electronics and other industries. It can be used to test high, medium and low gas barrier materials with outstanding efficiency.
Gas permeation testing Laboratory Gas Permeability Testing Equipment
Product Introduction The N500A 2.0 Gas Permeability Tester is a high - precision experimental testing equipment that integrates machinery, electronics, and software. It is suitable for testing the gas barrier properties of plastic films, composite films, sheets, metal foils, etc., as well as the gas permeability testing of packaging containers such as plastic, rubber, paper - based bottles, bags, cans, and boxes.  
Differential Pressure Gas Transmission Tester Differential Pressure Method Gas Transmission Tester N530A 2.0
Introduction The N530A 2.0 Gas Permeability Tester is designed and manufactured based on the differential pressure testing principle, in accordance with standards such as GB/T 1038 and ISO 2556. It adopts a high-precision pressure sensor and automatic pressure difference maintenance technology, ensuring high testing accuracy. It is suitable for testing the gas permeability of films, sheets, paper, packaging materials and related products in fields including food, pharmaceuticals, medical devices, daily chemicals, and photovoltaic electronics. It provides wide-range and high-efficiency gas permeability detection for high, medium, and low gas barrier materials.
Heat Shrink Tester Heat Shrink Tester ASTM D2732 GBK-1
GBK-1 Heat Shrinkage Tester is for testing the heating shrinkage of packaging films submerged in liquid in different temperatures.
Grating Spectrophotometer Densitometer GBPI Grating Spectrophotometer Densitometer
1.Perfect combination of the beautiful appearance and the ergonomic structure design; 2.Combined LED light sources with long life and low power consumption, including UV light; 3.Switchable apertures: Φ2/4/8mm, adapt to more samples; 4. Accurately measure reflectance spectrum, CMYK density and Lab value of the sample; 5.High-configuration electronic hardware: 3.5-inch TFT true-color screen, capacitive touch screen, concave grating, 256-pixel dual-array CMOS image sensor, etc.; 6.Two standard observer angles: 2/10, multiple light source modes and color systems; 7.USB mode is widely used. 8.Large-capacity storage space, over 10,000 test data; 9.Especially suitable for process control and quality control of printing plants;10. PC software has powerful function expansion.
PCT test chamber PCT Test Chamber Pressure Cooker test chamber GB-OPCT-30
1.Function It’s widely used in rubber products, magnetic materials, circuit boards, muti-layer circuit boards, IC, LCD, electronics and other products sealing performance testing.   2.Characteristics 1) The imported double-temperature structure with high temperature resistant solenoid valve is used to minimize the failure rate. 2) Independent steam generation chamber to avoid direct impact of steam on the product, so as not to cause partial damage to the product. 3) The door lock labor-saving structure solves the shortcomings of the locking difficulty of the first-generation product disc handle. 4) Cool air before the test; the design of the exhaust air in the test (air discharge in the test barrel) improves the pressure stability and reproduction. 5) Ultra long-term experimental running time up to 400 hours. 6) Water level protection, through the test room water level Sensor to detect protection. 7) Tank with anti-pressure design, the box body with pressure (150 ° C) up to 2.65kg, in line with the water pressure test of 6kg. 8) Two-stage pressure safety protection device, adopting two-stage combined controller and mechanical pressure protection device. 9) Safety protection pressure button, two-stage automatic pressure button for emergency safety device. 10) Bias test terminal withstand voltage up to 3000V (optional) 11) USB for exporting the history data, curve. 3.Technical parameters 1)Temperature range: +100°C~+132°C (Saturated vapor temperature) 2)Humidity Range: 100% steam Humidity 3)Humidity Control Stability: ±1%RH 4)Working pressure: 1.2~2.89kg/cm2 (including 1atm) 5)Time Range: 0 Hr to 999 Hr 6)Pressurization time: 0.00 Kg ~ 1.04 Kg/cm2 about 45 minutes 4.Material of chamber 1)Test chamber size:∮300 mm x L500 mm; 2)Overall size: W900x D900 x H1400 mm; 3)Inner barrel material: Stainless steel plate material (SUS# 316, 3mm); 4)Outer barrel material: stainless steel plate material or spray plastic; 5)Insulation material: rock wool and hard polyurethane foam insulation 6)Steam chamber heating tube: Titanium tube is heated and never rusts. 7)Control System: Taiwan-made Delta color touch PLC to control humidity and steam temperature (using PT-100 Platinum temperature sensor). (Imported large-screen touch controller) 5.Mechanical structure 1)Round inner box, stainless steel round test inner box structure, in line with industrial safety container standards, can prevent dew condensation design during test. 2)Round lining, stainless steel circular lining design, can avoid direct impact of vapor latent heat on the sample. 3)Precision design, good air tightness, low water consumption, and can be operated continuously for 400Hrs every time. 4)The patented packing design makes the door and the box more tightly combined, which is completely different from the traditional extrusion type, and can extend the packing life. 5)Critical point LIMIT mode automatic safety protection, abnormal cause and fault indicator display. 6)Security Protection: a)Imported high temperature sealed solenoid valve adopts double circuit structure to ensure no leakage of pressure. b)The whole machine is equipped with over-pressure protection, over-temperature protection, one-button pressure relief, manual pressure relief and multiple safety guarantee devices to ensure users to the greatest extent. c)Use and safety. d)Back pressure door lock device, the test box door cannot be opened when there is pressure inside the test chamber. 6.Other accessories. 1)Test rack 1 group 2)Sample tray   7.Ambient environment & Facilities. 1)It can be allowed to use the working environment temperature 5 ° C ~ 30 ° C; experimental water: pure water or distilled water 2)System power fluctuations should not be greater than ± 10, 220V 20A.    
Ozone Aging Test Chamber Ozone Aging Test Chamber (Dynamic Stretching) GB-OCY-150M
1 Function Ozone in the atmosphere is very little, while it’s a major factor in rubber cracking, the product simulate and enhance atmospheric ozone condition to study the role of ozone on the rubber, and to rapid identificate and evaluate rubber resistance for ozone aging and anti-ozone agent protection. According to“GB / T7762-2003 Test Method for Static Tensile Test of Ozone Resistance Cured Rubber or Thermoplastic Rubber”,“GB / T2951.21-2008 General Test Method for Insulation and Sheathing Material of Cable”,“GB / T 11206-2009 Rubber Aging test surface cracking method”, and other relevant standards of the test method. 2.1 Structure  All-in-one machine 2.2 Material a) Inner chamber: SUS304 stainless steel plate b) External chamber: SUS304 stainless steel plate or baking finish. Insulation: rigid polyurethane foam + aluminum insulation cotton with double protection. 2.3 Machine door a) Single door, open from left. b) Window frame / door frame with two silicone rubber seal and anti-condensation heating device. c)With observation window (W220xH250mm), lights above the window and door.  2.4 Requirements for sample holder (for dynamic-type only)       a)At both ends of the sample to be fixed with a clamp under the required elongation, the longitudinal direction of the specimen shall be substantially parallel to the direction of air flow when in contact with ozonized air. b) Clamps shall be made of a material (eg aluminum) which does not readily decompose ozone. c) Allow the sample to rotate at a speed between (20 ^ -25) mm / s, in a plane perpendicular to the dry gas flow, with each sample moving continuously along the same path. d) The time of one revolution of the same specimen is (8 ^ -12) min. The scanning area of the specimen shall be at least 40% of the effective area of the test chamber. Specimen preparation shall conform to the provisions of GB / T 9865.1. The test specimen is preferably cut from the new test piece and, if desired, may be cut from the finished product. At least 3 specimens shall be required for per test condition. The standard length of the specimen is not less than 10mm, and thickness not less than 0.2mm. The length of specimen between the two ends of the clamp before drawing is not less than 40mm. 3 Control panel a) Controller display b) Power switch c) Fault alarm d)Wavelength switch e)light switch button 4 Enclosure configuration a) With a stainless steel SUS # 304 shelf turntable b) One φ50mm lead hole:, and with a hole cover and silicone rubber plug. c) Move casters 4 pcs d) Horizontal mounting brackets 4 pcs e) There is a drainage hole in the back of the machine to facilitate the drainage of condensate; (8mm in diameter) Three-phase five-wire cable (four-core cable + protective grounding wire) 1 pc, (three meters long).
Modified Atmosphere Refrigerator Laboratory Refrigerator to Keep Freshness of Food and Vegetables GQ-300
GQ-300 Modified Atmosphere Refrigerator is a kind of Laboratory Refrigerator with microelectronics technology, is for making preservation experiment on fruits, vegetables, flowers and plants in modified atmosphere conditions, and keeps them fresh by controlling concentration of O2, N2, CO2, and C2H4 and the temperature and humidity in the boxes. It is widely used in industries of microorganisms, environmental, food, research institute and so on.
Pendulum Impact Tester Pendulum Impact Tester High Impact Speed Scale Value GBD-B
GBD-B Pendulum Impact Tester test the impact resistance of various films, metallic foil and so on, widely used in industrial and mining enterprises, laboratory, scientific research, teaching, inspection agency and so on.
  • Facebook
  • Linkedin
  • Youtube
  • Twitter

Copyright @ 2026 Guangzhou Biaoji Packaging Equipment Co.,Ltd. All Rights Reserved.

Chat now

Inquiry Now

Home

Products

NEWS

contact