Automatic High Precision Digital Thickness Meter is a high precise thickness meter integrating optics, mechanology , electronics and algorithm. Easy to operate. Test results are displayed digitally. And can connect to computer for automatic control.


  • Brand:

    GBPI
  • Item NO.:

    GH-D
  • Payment:

    T/T, LC
  • Product Origin:

    Guangzhou China
  • Lead Time:

    More than two weeks
Inquiry now Download
Product Detail

Standards

ISO 4593, ISO 534, ISO 3034, ASTM D1777, ASTM F2251, ASTM D645, ASTM D374, TAPPI T411, DIN 53105, DIN 53353, JIS K6250, JIS K6328, JIS K6783, JIS Z1702, BS 3983, BS 4817, GB/T 6672, GB/T 451.3, GB/T 6547


Features

High precision (0.1μm), digital display, stable, easy to operate.

Measuring mode: manual and automatic.

Single point and multiple points measurement.

LCD display, real time display of max, min, average and current values.

With built-in printer, can print test report.

Test range

0~6mm

Test resolution

0.1 μm

Number of test points

0~30 points

Space of sampling

0~100mm

Measure force

0.4 N

Measure head size

Φ6mm

Power

100W

Power supply

AC 220V, 50Hz

Instrumentsize

410mm ×310mm × 340mm

Weight

19.5kg

Send A Message

Leave us a message, we will get back to you ASAP.

Related Products
Thickness Tester Plastic Film Digital Thickness Tester
Didital thickness tester is used to make thickness measuring or comparative measuring of plastic film, thin sheet, paper and so on.
aluminum film Vacuum Coating Thickness Tester Vacuum Coating Thickness Tester For Vacuum Aluminum Film GH-E
Vacuum Coating Thickness Tester is applied to various vacuum aluminum film, aluminized paper, and other conductive coating materials to test the resistance value, evenness, thickness and so on.
Astm d1777 thickness tester for Fabric Astm d1777 thickness tester for Fabric digital thickness gauge of solid electrical insulation laboratory paper dial thickness test device
The thickness of the film material, an important characteristic of the packaging material, varies and is critical for other properties such as permeability, tensile strength, impact resistance, etc.
Professional high accuracy barrier film Electrolytic sensor method water vapor permeability analyzer-W203 2.0 supplier high accuracy barrier film Electrolytic sensor method water vapor permeability analyzer-W203 2.0
Introduction Based on the test principle of electrolytic sensor method, W203 2.0 Water Vapor Permeability Analyzer is designed and manufactured according to GB/T 21529, ISO15106-3 standard, based on the test principle of electrolytic method. W203 2.0 is suitable for the water vapor transmission performance test of films, sheets, papers, packages and various materials in the fields of food, medicine, medical equipment, daily chemicals, photovoltaic electronics, etc. It is an ideal configuration instrument for testing the barrier properties of packaging materials in the packaging production industry whether offline or online  
6 GBB-R2 Auto Melt Flow Indexer
Product introduction It is used to determine the MFR&MVR value of the melt flow rate through the standard die every 10 minutes when various plastics and gums pass through a certain temperature and load in a viscous flow state. It is suitble for melting high temperature polycarbonate, polysulfoxide, fluorine plastics, nylon and other engineering plastics. Also, it is appropriate for the polyformaldehyde, polystrene, polypropylene, ABS resin polyformaldehyde, polycarbonate resin and other low temperature plastic melting test. The machine is widely used in plastic production, plastic products, petrochemical and other industries as well as related universities, scientific research units and commodity inspection departments.
Lab  Teser Use for fabric China meltblown tester ppe testing equipment for fabric viral filtration efficiency tester
It is used to test the percentage of materials containing bacteria suspended particles at the specified flow rate. The dual gas path simultaneous comparison sampling method is used to improve the accuracy of sampling, which is suitable for the performance testing of bacterial filtration efficiency of medical surgical masks by metrological inspection departments, scientific research institutes, medical mask manufacturers and other relevant departments.
mask testing machine Facial Mask Flame Retardant Tester - GB-ZR10
Face Mask Flame Retardant Tester is a special test instrument for the flame retardancy of a mask. Mask testing machines for surgical face masks, N95 masks, Melt-blown fabric.    
Electronic Tensile Tester Electronic Digital Tensile Tester Machine GBL-L
GBL-L Electronic Digital Tensile Tester Machine apply to test the tensile strength, peeling strength, heat sealing strength and tearing strength of plastic film, composite film, tape, soft packaging material, rubber sheets, paper, non-woven fabrics and other packaging materials, widely used in industries of membrane, packaging, pharmaceuticals, food industries, inspection agency, research institute, college and so on.
Salt Spray Tester Salt spray test chamber GB-OSH-60
  1. FunFunction Salt spray test chamber is used for the quality inspection and corrosion resistance test of a variety of materials, including metal plating, metal, electronic components, chemical coatings, paint, automobiles, motorcycles, metal ware, screws, springs, magnetic materials, organic and inorganic coating, anodizing, anti-rust oil industry etc. after the surface treatment.   1. ecGTechnical parameters   1. MODEL GB-OSH-60 2. Temperature inside chamber 35℃±1℃/ 50℃±1℃ 3. Temperature of pressure barrel 47℃±1℃/ 63℃±1℃  4. Inner size W600 x H400 x D450mm   5. External size W1080 x H1080 x D650mm 6. Temperature Uniformity ≤±2℃ 7. Uniformity Fluctuation ≤±0.5℃ 8. Salt fog settlement 1~2ml/h.80cm2 9. Compressed air pressure 1.00±0.01kgf/cm² 10. Spray mode Continuous or intermittent spray optional 11. Power supply AC  220V   50Hz   1.5KW a)  Temp. range: RT+10℃ ~ 55℃ (temperature up to 50C, thickening PVC or PP material is recommended ) b) Humid. range: ≥93%R.H c) Controller time shown: 9.9s~9990hrs d) Timer: 0~9999hrs. e) Testing method: Neutral salt spray test (NSS test), acetic acid salt spray test (AASS test), salt spray test (SS test), copper accelerated acetic acid salt spray test method for salt spray test (CASS test) and so on; (For CASS test, we recommend the PP material chamber with high temperature resistance) f) Specimen holder: It can meet the tilt test at 15 ℃ ~ 30 ℃ (two layers); g) Air compressor: V-0.013/12.5(Customer provided); discharge pressure:1.25M; flow amount: 0.13m3/min   1. MMMaterial of machine body a) Salt spray chamber adopts the quality PVC reinforced hard plastic plate, the surface is smooth and anti-aging, anti-corrosion; b) Without any FRP material produced on the surface because of discoloration fibrosis. Plastic structure of the chamber is better to meet strong acid salt spray test under long-term without any damage. c) Cover is imported transparent impact-resistant plate which is convenient to test specimen when test, that can cover and the box with a water seal to prevent leakage of salt spray.   2. AccAccording to CSN, JIS, ASTM standards, can be set to constant temperature control: (a) Brine spray test: NSS (neutral); · Temp. inside chamber: 35 ℃ ± 1 ℃ · Pressure air bucket: 47 ℃ ± 1 ℃ (b) Corrosion resistance test: CASS (copper acceleration), AASS (acid) · Temp. inside chamber: 50 ° C ± 1 ° C · Pressure air bucket: 63 ℃ ± 1 ℃   3. Watwatering system. It adopts the auto watering system, supply water when lack of water. 4. HeaHeating system Test temperature inside the cabinets is heated humidification water jacket, the heater adopts advanced titanium protective tube, built-in nickel-chromium alloy infrared heater core. Heating up fast, uniform temperature distribution; and saves about one half of the power compared to FRP tank jacketed heating. 5. ExeExecutive standard GB/T 2423.17 Basic test procedures for electric and electronic products Ka"- salt spray test methods; GB/T 10125 Corrosion tests in artificial atmospheres – salt spray tests; ASTM B368 Test Method for Copper-Accelerated Acetic Acid-Salt Spray (Fog) Testing (CASS Test); JIS Z2371-2000 Methods of salt spray testing etc. ISO 9227 Corrosion tests in artificial atmospheres (Note: 2 collection device is required, bigger models than ZH-SH-90 (270L) is required; In some versions, it specifies over 400liters is necessary)  ASTM B117-18 Standard Practice for Operating Salt Spray (Fog) Apparatus (Note: 2 collection device is required, bigger models than ZH-SH-90 is required )  
COF tester GM-4 Coefficient of Friction Tester
  The coefficient of friction tester GM-4 is a measuring instrument developed and manufactured by the Guangzhou Biaoji R&D team based on various test standards of GB, ISO, ASTM and market demand. The measured friction coefficient determines the smoothness and opening difficulty of the film. and uniformity can be accurately determined, so as to correctly guide the production. It is suitable for measuring the static friction coefficient, dynamic friction coefficient and peel strength of plastic films, composite films, aluminum foils, aluminized films, plates, rubber, ceramics and other materials when sliding.        
Battery Diaphragm Gas Permeability Tester Battery Diaphragm Gas Permeability Tester N600E
  Introduction Battery Diaphragm Gas Permeability Tester N600E is designed and developed according to GB/T 36363-2018 and other standards. It adopts the test principle of differential pressure method and is professionally used for testing the air permeability of battery separators, breathable membranes and related polymer materials. Test principle In the environment of test temperature, humidity and normal pressure, under the pressure of 1.21kPa applied by the test instrument, the time required for 100mL air to pass through the diaphragm with an area of 6.45 cm2.   Standard ISO 5636-5, TAPPI T460, GB/T 36363 Specification Test range 60~12000 s/100mL Resolution 0.1 s/100mL Pressure range 0~3 KPa Pressure resolution 0.001 kPa Test area 6.45cm2 Sample size >50 mm×50 mm Instrument Size 450 mm×400 mm×300 mm Power 100W Power supply 110~250 VAC, 50~60 Hz   Features     The pressure difference of the instrument is adjustable in the range of 0~3 kPa, with an accuracy of 0.001 kPa, which fully meets the test pressure difference requirements of different methods;     The instrument supports s/100mL and um/(Pa.s) multi-unit display.     The test range can be customized according to different sample requirements.     The host is equipped with a color touch screen, no need for an external computer, and the air permeability of the sample can be observed in real time; Built-in micro-printer, which can print test report in real time; Application   Lithium Ion Battery Polyolefin separator for lithium ion battery, coated polyolefin separator for lithium ion battery or separator for lithium ion battery using other materials  
plastic bags leakage tester Flexible packaging test equipment Hermetic sealing tester leak tester GB-M
leakage tester To test the hermetic sealing quality and performance of packaging bags, bottles, cans and so on, used in industries of food, beverage, pharmaceuticals, personal care and so on.
  • Facebook
  • Linkedin
  • Youtube
  • Twitter

Copyright @ 2026 Guangzhou Biaoji Packaging Equipment Co.,Ltd. All Rights Reserved.

Chat now

Inquiry Now

Home

Products

NEWS

contact