packaging testing equipment Water Vapor Permeation Tester
Products
Home /

Physical Property Test Equipment

/

Thickness Tester

/Automatic High Precision Digital Thickness Meter

Automatic High Precision Digital Thickness Meter

Automatic High Precision Digital Thickness Meter is a high precise thickness meter integrating optics, mechanology , electronics and algorithm. Easy to operate. Test results are displayed digitally. And can connect to computer for automatic control.


  • Brand:

    GBPI
  • Item NO.:

    GH-D
  • Payment:

    T/T, LC
  • Product Origin:

    Guangzhou China
  • Lead Time:

    More than two weeks
Inquiry now Download
Product Detail

Standards

ISO 4593, ISO 534, ISO 3034, ASTM D1777, ASTM F2251, ASTM D645, ASTM D374, TAPPI T411, DIN 53105, DIN 53353, JIS K6250, JIS K6328, JIS K6783, JIS Z1702, BS 3983, BS 4817, GB/T 6672, GB/T 451.3, GB/T 6547


Features

High precision (0.1μm), digital display, stable, easy to operate.

Measuring mode: manual and automatic.

Single point and multiple points measurement.

LCD display, real time display of max, min, average and current values.

With built-in printer, can print test report.

Test range

0~6mm

Test resolution

0.1 μm

Number of test points

0~30 points

Space of sampling

0~100mm

Measure force

0.4 N

Measure head size

Φ6mm

Power

100W

Power supply

AC 220V, 50Hz

Instrumentsize

410mm ×310mm × 340mm

Weight

19.5kg

Send A Message

Leave us a message, we will get back to you ASAP.

Related Products
Thickness Tester Plastic Film Digital Thickness Tester
Didital thickness tester is used to make thickness measuring or comparative measuring of plastic film, thin sheet, paper and so on.
aluminum film Vacuum Coating Thickness Tester Vacuum Coating Thickness Tester For Vacuum Aluminum Film GH-E
Vacuum Coating Thickness Tester is applied to various vacuum aluminum film, aluminized paper, and other conductive coating materials to test the resistance value, evenness, thickness and so on.
Astm d1777 thickness tester for Fabric Astm d1777 thickness tester for Fabric digital thickness gauge of solid electrical insulation laboratory paper dial thickness test device
The thickness of the film material, an important characteristic of the packaging material, varies and is critical for other properties such as permeability, tensile strength, impact resistance, etc.
ISO 2248 Incline Impact Testers For Packages Packaging Impact Strength Test ISTA 6 Packaging Test Bundle
The Inclined Impact tester is simulated the impact strength of packaging in the real circumstance of transport such as handling, stacking of shelves, sliding, loading , transportation of products. This product is also can supply as the test machine to scientific research institution, college, packaging technique test centre, packaging material manufacture and foreign trade or transport department.
Ozone Aging Test Chamber Ozone Aging Test Chamber (Dynamic Stretching) GB-OCY-150M
1 Function Ozone in the atmosphere is very little, while it’s a major factor in rubber cracking, the product simulate and enhance atmospheric ozone condition to study the role of ozone on the rubber, and to rapid identificate and evaluate rubber resistance for ozone aging and anti-ozone agent protection. According to“GB / T7762-2003 Test Method for Static Tensile Test of Ozone Resistance Cured Rubber or Thermoplastic Rubber”,“GB / T2951.21-2008 General Test Method for Insulation and Sheathing Material of Cable”,“GB / T 11206-2009 Rubber Aging test surface cracking method”, and other relevant standards of the test method. 2.1 Structure  All-in-one machine 2.2 Material a) Inner chamber: SUS304 stainless steel plate b) External chamber: SUS304 stainless steel plate or baking finish. Insulation: rigid polyurethane foam + aluminum insulation cotton with double protection. 2.3 Machine door a) Single door, open from left. b) Window frame / door frame with two silicone rubber seal and anti-condensation heating device. c)With observation window (W220xH250mm), lights above the window and door.  2.4 Requirements for sample holder (for dynamic-type only)       a)At both ends of the sample to be fixed with a clamp under the required elongation, the longitudinal direction of the specimen shall be substantially parallel to the direction of air flow when in contact with ozonized air. b) Clamps shall be made of a material (eg aluminum) which does not readily decompose ozone. c) Allow the sample to rotate at a speed between (20 ^ -25) mm / s, in a plane perpendicular to the dry gas flow, with each sample moving continuously along the same path. d) The time of one revolution of the same specimen is (8 ^ -12) min. The scanning area of the specimen shall be at least 40% of the effective area of the test chamber. Specimen preparation shall conform to the provisions of GB / T 9865.1. The test specimen is preferably cut from the new test piece and, if desired, may be cut from the finished product. At least 3 specimens shall be required for per test condition. The standard length of the specimen is not less than 10mm, and thickness not less than 0.2mm. The length of specimen between the two ends of the clamp before drawing is not less than 40mm. 3 Control panel a) Controller display b) Power switch c) Fault alarm d)Wavelength switch e)light switch button 4 Enclosure configuration a) With a stainless steel SUS # 304 shelf turntable b) One φ50mm lead hole:, and with a hole cover and silicone rubber plug. c) Move casters 4 pcs d) Horizontal mounting brackets 4 pcs e) There is a drainage hole in the back of the machine to facilitate the drainage of condensate; (8mm in diameter) Three-phase five-wire cable (four-core cable + protective grounding wire) 1 pc, (three meters long).
Professional W416 2.0 Water Vapor Transmission Rate Tester supplier W416 2.0 Water Vapor Transmission Rate Tester
W416 2.0 Infrared Water Vapor Transmission Rate Tester High Precision WVTR Tester | 6 Independent Test Chambers Product Introduction W416 2.0 Infrared Water Vapor Transmission Rate Tester is an upgraded high-end precision testing instrument developed by GBPI R&D team in accordance with GB/T 26253, ASTM F1249 and international standards. Based on infrared moisture sensor technology, it provides wide-range and high-efficiency WVTR test for high, medium and low barrier materials. It is widely used for films, sheets, paper, packages and materials in food, pharmaceutical, medical devices, daily chemical, photovoltaic and electronics industries, ideal for offline and online testing in packaging industry. Get a Free Quote Today   Test Principle W416 2.0 adopts the infrared sensor testing principle. The pre-processed sample is fixed in the test chamber, dividing it into wet and dry sides. Compressed air flows in the wet chamber, and dry nitrogen (carrier gas) flows in the dry chamber at a fixed rate. Due to humidity gradient, water vapor permeates to the dry chamber and is carried to the infrared sensor. The WVTR value is calculated by the electrical signal output from the sensor.   Compliant Standards ISO 15106-2 ISO 21760-1 ASTM F1249 GB/T 26253 JIS K7129-2 Chinese Pharmacopoeia 4010 YBB 00092003   Technical Specifications Item Value Test Range 0.002~100 g/(m²·24h) Repeatability 0.005 or 2% (whichever is greater) Resolution 0.0001 g/(m²·24h) Temperature Range 15~45℃ Temperature Accuracy ±0.1℃ Humidity Range 5~90%RH, 100%RH Humidity Accuracy ±1%RH Test Area 50.24 cm² Sample Size Φ100 mm Sample Thickness ≤3 mm Test Chambers 6 channels (independent data)   Key Features Patented high-precision infrared moisture sensor, ultra-high stability, resolution up to 0.0001 g/(m²·24h). Automatic pneumatic control system, one-key sample clamping, excellent sealing and easy operation. Precise temperature & humidity control: ±0.1℃, ±1%RH, stable and reliable test data. 6 independent test chambers for high-throughput and high-efficiency testing. Real-time display of 5 test curves: WVTR-time, temperature-time, humidity-time, flow-time, voltage-time. Intelligent OS with audit trail, multi-level user rights, fully compliant with GMP. Calibrated with national standard substances (GBW(E)130543 / GBW(E)130544) for authoritative data. Support laboratory intelligent IoT platform: remote data management, remote diagnosis, resource download.   Applications Plastic Films PET, PE, BOPP, composite films, degradable films, aluminum-plated films, etc. Sheets Pharmaceutical rigid sheets, metal composite sheets, rubber sheets, etc. Paper & Paperboard Coated paper, aluminum paper, paper-plastic composite materials, etc. Medical Patches Medical plasters, transdermal patches, healthcare dressings, etc. Packaging Components Bottles, tubes, trays, bags, plastic containers, etc.
filling and sealing machine Automatic Rotary Pouch Spout inserting and Sealing Machine GF-1600H
This sealing/filling/capping machine(Packaging Machine/Packaging Machinery)is applicable for Fruit Juice/Salt /Sanitizing Gel/Skin Care/Sugar Powder/Tomato Sauce/ Ketchup/ Detergents Soap Packing in form of top/corner spout pouch or top/corner spout stand up pouch, 3-side sealing bags, and doypacks.
Professional Carbon Paper Air Permeability Rate Tester supplier Carbon Paper Air Permeability Rate Tester
Product Brief The N600C Carbon Paper Air Permeability Rate Tester is designed and developed in accordance with GB/T 20042.7-2014. Adopting the differential pressure method as its testing principle, it is professionally used for measuring the air permeability rate of various types of carbon paper for proton exchange membrane fuel cells (PEMFC). Testing Principle Based on the differential pressure method, the sample is placed between two fixtures, forming a constant differential pressure on both sides of the sample. Driven by the differential pressure, gas flows from the high-pressure side through the sample to the low-pressure side. The air permeability rate of the carbon paper is calculated based on the transmission flow rate, sample thickness, test area, and test differential pressure. Executed Standards GB/T 20042.7-2014 Technical Parameters Item Technical Parameters Test Range 0~200,000 mL·mm/(cm²·h·mmHg)0~14,701 mL·mm/(cm²·hr·mmAq) Resolution 0.1 mL·mm/(cm²·h·mmHg)0.1 mL·mm/(cm²·hr·mmAq) Pressure Range 0~500 Pa (other ranges available upon request) Pressure Resolution 0.1 Pa Pressure Accuracy 0.1% FS (Full Scale) Flow Range 0~50 L/min (other ranges available upon request) Flow Resolution 1 mL/min Flow Accuracy 1% FS (Full Scale) Test Area 16 cm² Instrument Dimensions 410 mm×295 mm×365 mm Power 100 W Power Supply 110~250 VAC, 50~60 Hz Product Features • The instrument's differential pressure is adjustable within the range of 0~500 Pa, with an accuracy of 0.1% FS, fully meeting the test pressure requirements of different samples;• The test range can be customized according to different sample requirements;• Arbitrary pressure adjustment, fully automatic operation, and automatic measurement and calculation of results;• Equipped with a color touch screen, no external computer required;• Built-in micro-printer for real-time printing of test reports;• The upper computer software is designed in accordance with the new GMP Appendix "Computerized Systems", supporting functions such as hierarchical permission management, audit trail, and electronic signature (optional).  
Falling Dart Impact Tester Falling Dart Impact Tester GBD-L2
GBD-L2 falling dart impact tester is suitable for testing materials such as plastic film or sheet and steel plate coating with a thickness of less than 1mm. Under a given height of free falling dart impact, it can measure the energy (in Quality to express results) of plastic films,thin section specimens and other materials. Through the impact resistance test, it can prevent the packaging surface from being damaged when the packaging material is impacted or dropped due to insufficient toughness of the packaging material, and effectively avoid the product from being damaged due to impact or falling in the circulation link. It can be used in scientific research, teaching, industrial and mining enterprises, laboratories, research institutes and quality supervision departments.
Lab  Teser Use for fabric China meltblown tester ppe testing equipment for fabric viral filtration efficiency tester
It is used to test the percentage of materials containing bacteria suspended particles at the specified flow rate. The dual gas path simultaneous comparison sampling method is used to improve the accuracy of sampling, which is suitable for the performance testing of bacterial filtration efficiency of medical surgical masks by metrological inspection departments, scientific research institutes, medical mask manufacturers and other relevant departments.
Vacuum Decay Leak Detection Tester Dual Pressure Methods Vacuum Decay Leak Detection Tester AUTO GBM-L2
Introduction AUTO GBM-L2 Dual-Pressure Methods Vacuum Decay Leak Detection Tester adopts the test principle of vacuum decay method/pressure decay to detect micro-leakage of finished packaging. It can be applied to packaging systems composed of vials, ampoules, Leakage detection of pre-filled needles, eye drop bottles, HDPE bottles, infusion bottles/bags and other pharmaceutical packaging, food packaging, and chemical industry packaging.   Test principle The host is connected to a sealed test chamber customized according to the sample. When performing the vacuum decay method test, the instrument evacuates the test chamber, and a pressure difference is formed inside and outside the sample. Under the action of the pressure, the gas/liquid in the sample enters the test chamber through the leak hole. The main engine uses the absolute pressure sensor and the differential pressure sensor to monitor the pressure change in the chamber to judge whether the sample leaks. When performing the pressure decay method test, the instrument fills the test chamber with a predetermined air pressure, and the gas in the test chamber enters the sample through the leak hole. The host uses absolute pressure sensors and differential pressure sensors to monitor the pressure changes in the chamber to determine whether the sample is leaking.   Standard ASTM F2338-2009(2013),  YY-T 0681.18-2020,  USP<1207.2>, ASTM F2095   Specification Item Parameters Absolute Pressure Testing Range (0 - 300) kPa Differential Pressure Testing Range (-2 - 2) kPa Detection Sensitivity 1 - 3 μm Balancing/Testing Time 1 - 3600 s Vacuum Purge Time 1 - 3600 s Set Flow Rate 0 - 3 mL/min Testing System Dual Sensor Technology/Dual Cycle Testing Testing Chamber Customized according to the sample Applicable Products Vials, Ampoules, Prefilled Syringes, Infusion Bottles/Bags, etc. Detection Principle Vacuum Decay Method/Pressure Decay Method Dimensions of the Main Unit 495 mm455 mm280 mm Ambient Temperature 20℃ - 25℃ Relative Humidity 40% - 60% Working Power Supply AC 220V, 50HZ   Features u Dual-Pressure Methods, to help solve testing difficulties The double combination of vacuum decay method and pressure decay method solves the problem of easy misjudgment and false negative for freeze-dried powder injections containing vacuum in the bottle using a single vacuum decay method. Based on dual-sensor and dual-circulation system technology, high-quality absolute pressure sensor and differential pressure sensor, with an accuracy of 0.1% FS, can effectively detect large and small leaks, accurately calculate the leak hole diameter, and give a pass or fail judgment.   The instrument has low sensitivity and good test repeatability For rigid samples, the detection sensitivity is as low as 1 μm, and the test repeatability is as low as 0.8%. The instrument has stable performance, low noise and good repeatability. u Imported brand accessories, excellent performance Imported brand vacuum pump, pumping rate up to 3 L/s, noise as low as 50 DB, high ultimate vacuum, convenient oil level detection and replacement. The imported gas mass flow controller can simulate micro-leaks arbitrarily, with a resolution of 0.001 mL/min, which provides a reliable guarantee for the method verification of instrument sensitivity. u Large size touch screen, intelligent operation Color 7-inch touch screen, clear view, sensitive touch, easy to operate. Equipped with a micro-printer, USB data interface, and supports PC software measurement and control operation. The test software is designed according to the GMP appendix "Computerized System". It has an audit trail function and multi-level authority settings for users, which can meet the needs of the pharmaceutical industry for data traceability. u Personalized customization to meet the needs of different samples For different test samples, it supports customization of suitable test chambers to meet the needs of different tests. For the same type of samples, it supports customized nesting mode, which can realize the sharing of a test chamber for samples of various specifications.   Application       Freeze-dried powder injection Injection Prefill needle       Eye drops Plastic Ampoule BFS Infusion bags   Factory configuration Standard Host machine, vacuum pump, test chamber and 3 sets of yin and yang control (customized as required), 11-inch touch panel, professional software (GMP) Optional Imported gas flow meters, air compressors, printers, calibration certificates  
COF tester GM-1 0-10N plastic film packaging coefficient of friction tester
The coefficient of friction tester is used to test the coefficient of frictionof plastic film, thin sheet, paper and so on, widely used in packaging industry, film-making companies and packaging material inspection agencies.
  • Facebook
  • Linkedin
  • Youtube
  • Twitter

Copyright @ 2026 Guangzhou Biaoji Packaging Equipment Co.,Ltd. All Rights Reserved.

Chat now

Inquiry Now

Home

Products

NEWS

contact