packaging testing equipment Water Vapor Permeation Tester
Products
Home /

Physical Property Test Equipment

/

Thickness Tester

/Plastic Film Digital Thickness Tester

Plastic Film Digital Thickness Tester

Didital thickness tester is used to make thickness measuring or comparative measuring of plastic film, thin sheet, paper and so on.

  • Brand:

    GBPI
  • Item NO.:

    GH-3
  • Payment:

    T/T
  • Product Origin:

    Guangzhou China
  • Lead Time:

    More than two weeks
Inquiry now Download
Product Detail

 

Standards

ISO 4593, ASTM F 2251, GB/T 6672

 

Features

LCD display test data.

Can change battery; easy to use.

 

Technical Parameters

Measuring range 0~12.7mm
Resolution 0.001 mm
Working Temperature 0~40℃
Storage temperature -10~60℃
Working humidity ≤80%
Working power supply Li-ion battery 1pc, model CR1632, voltage 3V
Dimension 17cm*10cm*22cm
Weight

Approx. 5 kg

 

Send A Message

Leave us a message, we will get back to you ASAP.

Related Products
Digital Thickness Meter Automatic High Precision Digital Thickness Meter
Automatic High Precision Digital Thickness Meter is a high precise thickness meter integrating optics, mechanology , electronics and algorithm. Easy to operate. Test results are displayed digitally. And can connect to computer for automatic control.
aluminum film Vacuum Coating Thickness Tester Vacuum Coating Thickness Tester For Vacuum Aluminum Film GH-E
Vacuum Coating Thickness Tester is applied to various vacuum aluminum film, aluminized paper, and other conductive coating materials to test the resistance value, evenness, thickness and so on.
Astm d1777 thickness tester for Fabric Astm d1777 thickness tester for Fabric digital thickness gauge of solid electrical insulation laboratory paper dial thickness test device
The thickness of the film material, an important characteristic of the packaging material, varies and is critical for other properties such as permeability, tensile strength, impact resistance, etc.
Vacuum Freeze Dryer Vacuum Freeze Dryer GB-LGJ-200F
Introduction Factory use vacuum freeze dryer is suitable for drying product such as food, drug products, biological products, Chinese medicine and more. It is to dry product at low temperature to preserve, stabilize, store and increase the life of products.. Freeze vacuum drying is a new type of box structure introduced by the vacuum freeze dryer that combines the refrigeration system, vacuum system, heat transfer oil heating system, and moisture removal system. It uses the space for storing materials in the box to dry. Main Technical Parameters   Item GB-LGJ-200F Drying chamber Freeze-drying area 2.25m2 Layers of shelf 5+1 Temperature scope of shelf -50℃-+70℃ (no-load) Shelf temperature error ±1℃ (in balance) Shelf spacing 70mm Size of shelf 500mm*900mm Condenser Min. Temperature of condenser ≤-70℃ (no-load) Water-capture capability >30Kg Liquid material 22L(thickness 10mm) Defrosting Electric defrosting Final Vacuum degree ≤ 5Pa Style of cooling Fan cooling Main functions Manual + Auto Control Mode, Sensor calibration, Intelligent temperature control, Freeze drying termination reminding and other functions are available.               Technical parameters □ Main configuration   Shelf effective area 2.25 m2 □ Specification   Shelf size 500mm × 900mm   Shelf numbers 5+1(Radiation layer) Top shelf as temperature compensating plate   Material number plate 10 pcs   Shelf spacing 70 mm   Shelf temperature range -50℃~+70℃ (no-load)   Min. condenser temp. ≤ -70℃  (no-load)   System final vacuum degree ≤ 5Pa □ Basic configuration    Installation Power 13.5KW     ★ This is installed power, not operating power. □ Shape and other parts   Dimension(mm): About 1200x2100x1700mm, L*W*H   Weight(Kg):  About 1200   Noise ≤ 80dB   Electrical system Ground protection   Design, production, installation standards According to GMP, GB/T522 6.1-1996   Whole machine test Test, verify data, methods, and equipment support □ Drying chamber components   Shape Rectangular   Roughness of inner wall Ra ≤ 0.6μm   Opening direction Clockwise or anticlockwise (overlooking ,user confirm)   Chamber material AISI 304  stainless steel ◆  Door  material ACRYLIC   Working temperature ≥ 70℃   Thermal insulation material Polyurethane foam □ Shelf components ◆ Shelf material AISI 304  Top and bottom plate thickness 5mm ◆ Shelf structure AISI 304 stainless steel (Patent No. :ZL201020237059.X)   Roughness of shelf Ra ≤ 0.6 μm   Flatness ≤ ±0.5mm / m   Effective shelf size 500mm×900 mm   Amount of shelf 5+1     Effective area of shelf 2.25m2 ◆ Shelf spacing  70 mm   Temperature decreasing rate +20℃ down to -40℃/ within 60 min, (no-load, entrance of silicon oil )   Temperature elevating rate -40℃ up to +20℃/ within 60 min, (no-load, entrance of silicon oil ) ◆ Shelf lowest temperature ≤ -50℃      (no-load, entrance of silicon oil )   Shelf highest temperature ≥ +70℃    (no-load, entrance of silicon oil )   Shelf temperature error ≤ ±1℃ ≤ ±1℃ ( in balance ) □ Condenser components   Condenser Shape Vertical type, cylindrical Compact structure, better water capture ,easy to clean and defrosting ◆ Condenser material AISI 304   Condenser water capture ≥ 30Kg   Condenser temp. Decreasing +20℃--40℃, within 30 minutes ◆   Condenser Min. temp. ≤ -70℃   Defrosting Electrochemical cream ◆ Thermal insulation material Polyurethane foam □ Refrigeration system   Refrigerator France original imported TECUMSEH full closure compressor ◆ Refrigerant Environmentally friendly refrigerant   Refrigerator number 2 sets   Shelf refrigeration 1 sets (shelf refrigeration at same time, indirect refrigeration)   Condenser refrigeration 1 set (shelf refrigeration at same time, direct refrigeration) ★ World famous devices are used to make sure correct, stable, safe and reliable.   High pressure protection device When system’s air discharge pressure exceeds allowed pressure, machine automatically stops working, to avoid an accident.   expansion valve DANFOSS(Denmark)   Top cover valve Castel(Italy)   solenoid valve DANFOSS(Denmark)   Oil separator ZOER   High pressure controller DANFOSS(Denmark)   Disacidify filter DANFOSS(Denmark)   Pressure meter LR/REFCO LR/REFCO(Germany/Swiss) oil submerge  pressure meter   Water cooling condenser Well-known brand □ Vacuum system ◆ Double stage rotary vane pump Tan's Vacuum Pump   Quantity 1 set ◆ Vacuum gauge Reborn   Chamber pumping rate Atmosphere→10 Pa ≤30 minutes(in dry condition)   System Maximum vacuum ≤ 5Pa   System leaking rate ≤ 10 Pa·l / sec □ Liquid circulation system ◆   Liquid low viscosity silicon oil ( 25℃, 5cst ) National qualified product   Liquid tubing material AISI 304, welding, heat  keeping ◆ Circulation pump ★GRUNDFOS, original imports, web rotor canned pump From Denmark brand, world famous brand   Circulation pump quantity 1 set   Heating rate 4kW   Heating control style Solid-state relay ◆ Stainless steel plate heat exchanger Well-known brands   Temperature sensor PT-100 platinum resistance □  Control system ◆ Control style Automatic and manual control ◆ Control system FD-PILOT   Control board SH-HPSC-II   Touch screen MCGS   Intermediate relay CHINT   AC contactor CHINT   Air circuit-breaker CHINT   Wiring terminals: Well-known brands □ Safety protection   Whole machine protection All safety conditions are ready for whole machine, machine can start running.   Operation protection Electrical system have logic interlock, control and protection function   Vacuum pressure Available   Heating system Available   Power cut and supply With safety protection measure   Products protection during sublimation process Heat cutting if vacuum lack   Condenser protection when vacuum pump start Interlock □ Whole machine design   Power 3Ph+N+PE, 380V   Installed power 13.5 KW (this is installed power, not running power)   Whole machine structure Integrated structure (easy for transport and placement)   Whole machine size About  1200x2100x1700mm, L*W*H   Whole machine weight (kg) About 1200   Time of warranty: One year after site acceptance.  
DSC Tester DSC100A DSC Testing Lab Differential Scanning Calorimeter
High Precision DSC Differential Scanning Calorimeter Product Introduction This DSC is our highest-precision differential scanning calorimeter. It is equipped with imported thermocouple sensors featuring ultra-high sensitivity. The signal acquisition circuit adopts full shielding protection design, delivering strong anti-interference capability and excellent baseline stability. Adopting touch screen operation, this instrument can perform glass transition temperature test, phase transition analysis, melting enthalpy measurement, product stability evaluation and oxidation induction period test, covering a wide range of testing applications. Test Principle By measuring the heat flow difference between the sample and the reference material under programmed temperature control, the instrument analyzes thermal characteristic parameters such as melting point, glass transition temperature and oxidation resistance of polymer, pharmaceutical and packaging materials. Technical Parameters Temperature Range Room Temperature ~ 550 ℃ (Air Cooling) Temperature Resolution 0.01℃ Temperature Fluctuation ±0.1℃ Temperature Repeatability ±0.1℃ Heating Rate 0.1~100℃/min Constant Temperature Duration Programmable ≤ 24h Temperature Control Modes Heating, Constant Temperature DSC Heat Flow Range 0~±600mW DSC Resolution 0.01μW DSC Accuracy 0.001mW Power Supply AC 220V, 50Hz (Customizable) Atmosphere Control Gas Nitrogen, Oxygen (Automatic Instrument Switching) Gas Flow Rate 0-300ml/min Gas Pressure 0.2MPa Display Screen 7-inch 24-bit Color LCD Touch Screen Data Interface Standard USB Port Calibration Standard Comes with Indium & Tin Reference Materials for User Self Temperature Calibration PC Software Compatibility 3-in-1 Host Software, Compatible with TGA & Synchronous Thermal Analyzers Thermocouple Configuration 3 Groups of Thermocouples: Sample Temp, Furnace Temp, Internal Ambient Temp Technical Features
Crush Tester Crush Tester Paper Packaging Test Equipment
Paper Packaging Test Equipment 
Gas permeation testing Laboratory Gas Permeability Testing Equipment
Product Introduction The N500A 2.0 Gas Permeability Tester is a high - precision experimental testing equipment that integrates machinery, electronics, and software. It is suitable for testing the gas barrier properties of plastic films, composite films, sheets, metal foils, etc., as well as the gas permeability testing of packaging containers such as plastic, rubber, paper - based bottles, bags, cans, and boxes.  
WVTR Testing Equipment W812 Water Vapor Permeability Analyzer(Cup Method) WVTR Testing Equipment For Packaging
Product introduction This product is based on the test principle of cup method water vapor transmission, and is designed and manufactured according to ASTM E96, GB/T 1037 standards, and provides a wide range and high efficiency water vapor transmission rate detection for low, medium and high water vapor barrier materials. test. It is suitable for the water vapor transmission performance test of films, sheets, paper, fabrics, non-woven fabrics and related materials in the fields of food, medicine, medical equipment, daily chemicals, etc.
Face mask tester Multifunctional Tensile Tester for Face Mask - GBH-3
To test the tensile strength, peeling strength, heat sealing strength, tearing strength, piercing strength of plastic film, composite film, tape, soft packaging material, rubber sheets, paper, non-woven fabrics and other packaging materials
Film Pendulum Impact Tester Pendulum Impact Tester-GBG-L2
  Introduction Designed and manufactured according tostandards likeGB/T 8809、ASTM D3420, GBG-L2 Pendulum Impact Tester is suitable for determining pendulum impact resistance of the film materials,composite film,metallic foil and so on. The machine can be used in scientific research, teaching, industrial and mining enterprises, laboratory, research institute and quality supervision department.  
GBB-F1 Heat Seal Tester-GBB-F1
GBB-F1 Heat Seal Tester is to test the temperature, pressure, and time for heat sealing of various film materials. It is applied to quality inspection organizations, drug control institutions, research institutes, packaging, thin film, food companies, pharmaceutical enterprises, personal care industry and so on.
Ozone Aging Test Chamber Ozone Aging Test Chamber (Dynamic Stretching) GB-OCY-150M
1 Function Ozone in the atmosphere is very little, while it’s a major factor in rubber cracking, the product simulate and enhance atmospheric ozone condition to study the role of ozone on the rubber, and to rapid identificate and evaluate rubber resistance for ozone aging and anti-ozone agent protection. According to“GB / T7762-2003 Test Method for Static Tensile Test of Ozone Resistance Cured Rubber or Thermoplastic Rubber”,“GB / T2951.21-2008 General Test Method for Insulation and Sheathing Material of Cable”,“GB / T 11206-2009 Rubber Aging test surface cracking method”, and other relevant standards of the test method. 2.1 Structure  All-in-one machine 2.2 Material a) Inner chamber: SUS304 stainless steel plate b) External chamber: SUS304 stainless steel plate or baking finish. Insulation: rigid polyurethane foam + aluminum insulation cotton with double protection. 2.3 Machine door a) Single door, open from left. b) Window frame / door frame with two silicone rubber seal and anti-condensation heating device. c)With observation window (W220xH250mm), lights above the window and door.  2.4 Requirements for sample holder (for dynamic-type only)       a)At both ends of the sample to be fixed with a clamp under the required elongation, the longitudinal direction of the specimen shall be substantially parallel to the direction of air flow when in contact with ozonized air. b) Clamps shall be made of a material (eg aluminum) which does not readily decompose ozone. c) Allow the sample to rotate at a speed between (20 ^ -25) mm / s, in a plane perpendicular to the dry gas flow, with each sample moving continuously along the same path. d) The time of one revolution of the same specimen is (8 ^ -12) min. The scanning area of the specimen shall be at least 40% of the effective area of the test chamber. Specimen preparation shall conform to the provisions of GB / T 9865.1. The test specimen is preferably cut from the new test piece and, if desired, may be cut from the finished product. At least 3 specimens shall be required for per test condition. The standard length of the specimen is not less than 10mm, and thickness not less than 0.2mm. The length of specimen between the two ends of the clamp before drawing is not less than 40mm. 3 Control panel a) Controller display b) Power switch c) Fault alarm d)Wavelength switch e)light switch button 4 Enclosure configuration a) With a stainless steel SUS # 304 shelf turntable b) One φ50mm lead hole:, and with a hole cover and silicone rubber plug. c) Move casters 4 pcs d) Horizontal mounting brackets 4 pcs e) There is a drainage hole in the back of the machine to facilitate the drainage of condensate; (8mm in diameter) Three-phase five-wire cable (four-core cable + protective grounding wire) 1 pc, (three meters long).
  • Facebook
  • Linkedin
  • Youtube
  • Twitter

Copyright @ 2026 Guangzhou Biaoji Packaging Equipment Co.,Ltd. All Rights Reserved.

Chat now

Inquiry Now

Home

Products

NEWS

contact