  Features

 The inside wall is made of mirror stainless steel or steel drawing board, and main body made of high quality steel.

 Temperature control and protection, digital display and timing, accurate and stable.


Specifications 


Item

Technical Parameters

Temperature rang

room temperature+10℃~+200℃

Temperature fluctuation rate

1℃

Temperature resolution

0.1℃ 
Sensor
Pt100
Display
LED digit display
Outer shell 
anti-rust cold-reduced sheet with spray-paint 
Inner tank
SUS304 wire drawing stainless steel
Heat insulation 

super glass wool 
Heater
nickel-chrome heating wire 
Shelf capacity 
30L
Power
850W
Power supply

AC 220V 50Hz
Inner size
340mm x 320mm x 320mm 
Outer size
640mm x 440mm x 490mm
Weight 
34kg
Model
DHG-9030A


Send A Message

Leave us a message, we will get back to you ASAP.

Related Products
gas generator High purity nitrogen hydrogen and air gas generator for gas chromatography
gas generator can generates high purity nitrogen, hydrogen and air; it can supply stable and high quality gas for Gas Chromatography
Vacuum Freeze Dryer Vacuum Freeze Dryer GB-LGJ-200F
Introduction Factory use vacuum freeze dryer is suitable for drying product such as food, drug products, biological products, Chinese medicine and more. It is to dry product at low temperature to preserve, stabilize, store and increase the life of products.. Freeze vacuum drying is a new type of box structure introduced by the vacuum freeze dryer that combines the refrigeration system, vacuum system, heat transfer oil heating system, and moisture removal system. It uses the space for storing materials in the box to dry. Main Technical Parameters   Item GB-LGJ-200F Drying chamber Freeze-drying area 2.25m2 Layers of shelf 5+1 Temperature scope of shelf -50℃-+70℃ (no-load) Shelf temperature error ±1℃ (in balance) Shelf spacing 70mm Size of shelf 500mm*900mm Condenser Min. Temperature of condenser ≤-70℃ (no-load) Water-capture capability >30Kg Liquid material 22L(thickness 10mm) Defrosting Electric defrosting Final Vacuum degree ≤ 5Pa Style of cooling Fan cooling Main functions Manual + Auto Control Mode, Sensor calibration, Intelligent temperature control, Freeze drying termination reminding and other functions are available.               Technical parameters □ Main configuration   Shelf effective area 2.25 m2 □ Specification   Shelf size 500mm × 900mm   Shelf numbers 5+1(Radiation layer) Top shelf as temperature compensating plate   Material number plate 10 pcs   Shelf spacing 70 mm   Shelf temperature range -50℃~+70℃ (no-load)   Min. condenser temp. ≤ -70℃  (no-load)   System final vacuum degree ≤ 5Pa □ Basic configuration    Installation Power 13.5KW     ★ This is installed power, not operating power. □ Shape and other parts   Dimension(mm): About 1200x2100x1700mm, L*W*H   Weight(Kg):  About 1200   Noise ≤ 80dB   Electrical system Ground protection   Design, production, installation standards According to GMP, GB/T522 6.1-1996   Whole machine test Test, verify data, methods, and equipment support □ Drying chamber components   Shape Rectangular   Roughness of inner wall Ra ≤ 0.6μm   Opening direction Clockwise or anticlockwise (overlooking ,user confirm)   Chamber material AISI 304  stainless steel ◆  Door  material ACRYLIC   Working temperature ≥ 70℃   Thermal insulation material Polyurethane foam □ Shelf components ◆ Shelf material AISI 304  Top and bottom plate thickness 5mm ◆ Shelf structure AISI 304 stainless steel (Patent No. :ZL201020237059.X)   Roughness of shelf Ra ≤ 0.6 μm   Flatness ≤ ±0.5mm / m   Effective shelf size 500mm×900 mm   Amount of shelf 5+1     Effective area of shelf 2.25m2 ◆ Shelf spacing  70 mm   Temperature decreasing rate +20℃ down to -40℃/ within 60 min, (no-load, entrance of silicon oil )   Temperature elevating rate -40℃ up to +20℃/ within 60 min, (no-load, entrance of silicon oil ) ◆ Shelf lowest temperature ≤ -50℃      (no-load, entrance of silicon oil )   Shelf highest temperature ≥ +70℃    (no-load, entrance of silicon oil )   Shelf temperature error ≤ ±1℃ ≤ ±1℃ ( in balance ) □ Condenser components   Condenser Shape Vertical type, cylindrical Compact structure, better water capture ,easy to clean and defrosting ◆ Condenser material AISI 304   Condenser water capture ≥ 30Kg   Condenser temp. Decreasing +20℃--40℃, within 30 minutes ◆   Condenser Min. temp. ≤ -70℃   Defrosting Electrochemical cream ◆ Thermal insulation material Polyurethane foam □ Refrigeration system   Refrigerator France original imported TECUMSEH full closure compressor ◆ Refrigerant Environmentally friendly refrigerant   Refrigerator number 2 sets   Shelf refrigeration 1 sets (shelf refrigeration at same time, indirect refrigeration)   Condenser refrigeration 1 set (shelf refrigeration at same time, direct refrigeration) ★ World famous devices are used to make sure correct, stable, safe and reliable.   High pressure protection device When system’s air discharge pressure exceeds allowed pressure, machine automatically stops working, to avoid an accident.   expansion valve DANFOSS(Denmark)   Top cover valve Castel(Italy)   solenoid valve DANFOSS(Denmark)   Oil separator ZOER   High pressure controller DANFOSS(Denmark)   Disacidify filter DANFOSS(Denmark)   Pressure meter LR/REFCO LR/REFCO(Germany/Swiss) oil submerge  pressure meter   Water cooling condenser Well-known brand □ Vacuum system ◆ Double stage rotary vane pump Tan's Vacuum Pump   Quantity 1 set ◆ Vacuum gauge Reborn   Chamber pumping rate Atmosphere→10 Pa ≤30 minutes(in dry condition)   System Maximum vacuum ≤ 5Pa   System leaking rate ≤ 10 Pa·l / sec □ Liquid circulation system ◆   Liquid low viscosity silicon oil ( 25℃, 5cst ) National qualified product   Liquid tubing material AISI 304, welding, heat  keeping ◆ Circulation pump ★GRUNDFOS, original imports, web rotor canned pump From Denmark brand, world famous brand   Circulation pump quantity 1 set   Heating rate 4kW   Heating control style Solid-state relay ◆ Stainless steel plate heat exchanger Well-known brands   Temperature sensor PT-100 platinum resistance □  Control system ◆ Control style Automatic and manual control ◆ Control system FD-PILOT   Control board SH-HPSC-II   Touch screen MCGS   Intermediate relay CHINT   AC contactor CHINT   Air circuit-breaker CHINT   Wiring terminals: Well-known brands □ Safety protection   Whole machine protection All safety conditions are ready for whole machine, machine can start running.   Operation protection Electrical system have logic interlock, control and protection function   Vacuum pressure Available   Heating system Available   Power cut and supply With safety protection measure   Products protection during sublimation process Heat cutting if vacuum lack   Condenser protection when vacuum pump start Interlock □ Whole machine design   Power 3Ph+N+PE, 380V   Installed power 13.5 KW (this is installed power, not running power)   Whole machine structure Integrated structure (easy for transport and placement)   Whole machine size About  1200x2100x1700mm, L*W*H   Whole machine weight (kg) About 1200   Time of warranty: One year after site acceptance.  
Vacuum Decay Leak Detection Tester Dual Pressure Methods Vacuum Decay Leak Detection Tester AUTO GBM-L2
Introduction AUTO GBM-L2 Dual-Pressure Methods Vacuum Decay Leak Detection Tester adopts the test principle of vacuum decay method/pressure decay to detect micro-leakage of finished packaging. It can be applied to packaging systems composed of vials, ampoules, Leakage detection of pre-filled needles, eye drop bottles, HDPE bottles, infusion bottles/bags and other pharmaceutical packaging, food packaging, and chemical industry packaging.   Test principle The host is connected to a sealed test chamber customized according to the sample. When performing the vacuum decay method test, the instrument evacuates the test chamber, and a pressure difference is formed inside and outside the sample. Under the action of the pressure, the gas/liquid in the sample enters the test chamber through the leak hole. The main engine uses the absolute pressure sensor and the differential pressure sensor to monitor the pressure change in the chamber to judge whether the sample leaks. When performing the pressure decay method test, the instrument fills the test chamber with a predetermined air pressure, and the gas in the test chamber enters the sample through the leak hole. The host uses absolute pressure sensors and differential pressure sensors to monitor the pressure changes in the chamber to determine whether the sample is leaking.   Standard ASTM F2338-2009(2013),  YY-T 0681.18-2020,  USP<1207.2>, ASTM F2095   Specification Item Parameters Absolute Pressure Testing Range (0 - 300) kPa Differential Pressure Testing Range (-2 - 2) kPa Detection Sensitivity 1 - 3 μm Balancing/Testing Time 1 - 3600 s Vacuum Purge Time 1 - 3600 s Set Flow Rate 0 - 3 mL/min Testing System Dual Sensor Technology/Dual Cycle Testing Testing Chamber Customized according to the sample Applicable Products Vials, Ampoules, Prefilled Syringes, Infusion Bottles/Bags, etc. Detection Principle Vacuum Decay Method/Pressure Decay Method Dimensions of the Main Unit 495 mm455 mm280 mm Ambient Temperature 20℃ - 25℃ Relative Humidity 40% - 60% Working Power Supply AC 220V, 50HZ   Features u Dual-Pressure Methods, to help solve testing difficulties The double combination of vacuum decay method and pressure decay method solves the problem of easy misjudgment and false negative for freeze-dried powder injections containing vacuum in the bottle using a single vacuum decay method. Based on dual-sensor and dual-circulation system technology, high-quality absolute pressure sensor and differential pressure sensor, with an accuracy of 0.1% FS, can effectively detect large and small leaks, accurately calculate the leak hole diameter, and give a pass or fail judgment.   The instrument has low sensitivity and good test repeatability For rigid samples, the detection sensitivity is as low as 1 μm, and the test repeatability is as low as 0.8%. The instrument has stable performance, low noise and good repeatability. u Imported brand accessories, excellent performance Imported brand vacuum pump, pumping rate up to 3 L/s, noise as low as 50 DB, high ultimate vacuum, convenient oil level detection and replacement. The imported gas mass flow controller can simulate micro-leaks arbitrarily, with a resolution of 0.001 mL/min, which provides a reliable guarantee for the method verification of instrument sensitivity. u Large size touch screen, intelligent operation Color 7-inch touch screen, clear view, sensitive touch, easy to operate. Equipped with a micro-printer, USB data interface, and supports PC software measurement and control operation. The test software is designed according to the GMP appendix "Computerized System". It has an audit trail function and multi-level authority settings for users, which can meet the needs of the pharmaceutical industry for data traceability. u Personalized customization to meet the needs of different samples For different test samples, it supports customization of suitable test chambers to meet the needs of different tests. For the same type of samples, it supports customized nesting mode, which can realize the sharing of a test chamber for samples of various specifications.   Application       Freeze-dried powder injection Injection Prefill needle       Eye drops Plastic Ampoule BFS Infusion bags   Factory configuration Standard Host machine, vacuum pump, test chamber and 3 sets of yin and yang control (customized as required), 11-inch touch panel, professional software (GMP) Optional Imported gas flow meters, air compressors, printers, calibration certificates  
Bottle Wall Thickness Gauge Electronic Bottle Wall Thickness Gauge
Laboratory Glass Package Tester for Ampoule, injection bottle, infusion bottle, oral medicine bottle. Thickness testing, Burst, testing, Pressure Resistance testing, and Thermal Testing for Medical/Pharma Packages. 20+ Years Test Experience.
Composite Film Heat Seal Tester Composite Film Heat Sealing Analyzer With ASTM F2029 Testing Standard GBB-A
GBB-A Heat Seal Tester accurately test the heat seal temperature range, heat seal strength, suitable heat seal speed and heat seal pressure of plastic film, flexible packaging composite film, coated paper, aluminum foil, etc. It is applied to the quality control of various plastic film, food and drug manufacturer, the scientific research and teaching experiment of testing institutions and schools
Electronic Tensile Tester Electronic Digital Tensile Tester Machine GBL-L
GBL-L Electronic Digital Tensile Tester Machine apply to test the tensile strength, peeling strength, heat sealing strength and tearing strength of plastic film, composite film, tape, soft packaging material, rubber sheets, paper, non-woven fabrics and other packaging materials, widely used in industries of membrane, packaging, pharmaceuticals, food industries, inspection agency, research institute, college and so on.
Compression Resistance Tester Compression Tester for Bag Packaging GBN200A
The Compression Tester GBN200A is professionally used to test the pressure resistance and burst resistance of various packaging bags. It can set the pressure and measure the deformation; set the deformation and measure the pressure resistance. It is an ideal testing equipment for quality inspection, drug inspection, scientific research, packaging, film, food, medicine, daily chemical and other industries.
Gas Permeation Analysis Gas Permeation Analysis System GTR-10H
Product introduction The GTR-10H gas permeation analysis system consists of a differential pressure permeation device and a gas chromatograph. It can test and analyze the gas permeability of various single-component gases and mixed gases, and can accurately calculate the permeability, permeability coefficient and other parameters of each component gas. The test gas has a wide range of types and high accuracy, and is suitable for gas permeation testing in the fields of fuel cell proton exchange membrane gas permeability testing, hydrogen permeation of hydrogen storage materials, gas density of bipolar plate materials, and natural gas storage materials.   Test principle Place the processed sample between the high-pressure chamber and the low-pressure chamber, and the low-pressure chamber is connected to the gas chromatograph through a quantitative loop. At the set test temperature, use a vacuum pump to evacuate the gas system, and then add a certain pressure of test gas to the upper chamber to form a constant pressure difference between the upper and lower chambers. Under the action of the pressure gradient, the gas penetrates from the high-pressure chamber to the low-pressure chamber through the film. The system injects the gas that penetrates into the low-pressure chamber into the gas chromatography column and separates it into various components, and calculates the gas permeability, gas permeability coefficient and other barrier performance parameters of each component.   Standard GB/T 20042.3,GB/T 20042.6-2011,GB/T 1038.1-2022,ISO 15105-1   Specification Item Technical Parameters Test range 2.0×10-12~3.0×10-7 mol/(m2·s.Pa) Detection system Gas chromatography (GC), TCD detector Test gas Gases such as hydrogen, oxygen, nitrogen, carbon dioxide, carbon monoxide, methane, etc., single component or mixed component Gas pressure 0~300kPa Permeation module temperature control range 15~60℃ Temperature control accuracy ±0.1℃ Permeation area 50.24 cm2 Sample size Φ110 mm Sample thickness ≤2 mm Sample quantity 1 piece Power supply AC 220 V,50 Hz   Features Advanced gas chromatography analysis technology The instrument is equipped with an advanced gas chromatography analysis module and a new microcomputer temperature control system, which can achieve 16-step program temperature rise with high temperature control accuracy; it adopts multi-processor parallel working mode, and can be equipped with a variety of high-performance detectors. The instrument is stable and reliable, equipped with a 7-inch color LCD touch screen and a dedicated workstation, which is convenient to operate and easy to process data.   Fully automatic precision control of permeation module test temperature The permeation module uses semiconductor refrigeration chips to automatically control the temperature in both directions, with higher temperature control accuracy, up to 0.1℃.   Can test the permeability of single gas and mixed gas It can measure the permeability of a single gas and the permeability of different mixed gases at the same time, and has a wide range of uses. In addition to its application in the traditional packaging industry, it has broad application prospects in new energy fields such as hydrogen energy.   Intelligent operating system, global certification Self-developed intelligent operating system, modular graphics, flexible setting of test process parameters, and intuitive and convenient operation. Designed according to the GMP Appendix "Computerized System", it has an audit tracking function and multi-level user authority settings, which can meet the needs of the pharmaceutical industry for data traceability. Personalized test reports are set on demand, supporting data output in multiple formats, electronic signatures, and online submission of audit reports.   Laboratory Intelligent IoT Platform The instrument can be connected to the IoT platform to achieve digital network management. Remote authorization to log in to the IoT platform can achieve functions such as managing experimental data, remote diagnosis and troubleshooting. Customers can download the required instrument information, documents, and operation videos on the platform.
water vapor permeability WVTR MVTR Water Vapor Transmission Rate Testing Instrument Infrared Method for Plastic Film and Sheeting-W413
Moisture vapor permeability analyzer using infrared method is to test the water vapor transmission rate (WVTR) of films or sheets materials for food and pharmaceutical industries.
Pendulum Impact Tester Pendulum Impact Tester High Impact Speed Scale Value GBD-B
GBD-B Pendulum Impact Tester test the impact resistance of various films, metallic foil and so on, widely used in industrial and mining enterprises, laboratory, scientific research, teaching, inspection agency and so on.
Oxygen Permeability Analyzer Oxygen Permeability Analyzer - Coulometric Sensor Method
This product is based on the testing principle of the Coulometric Sensor Method testing Oxygen and is designed and manufactured with reference to ASTM D3985, GB/T 19789 and other standards. Adopting high-precision imported oxygen sensor, high test accuracy, it is suitable for oxygen transmission performance testing of films, sheets, paper, packaging and related materials in the fields of food, medicine, medical equipment, daily chemicals, photovoltaic electronics, etc., and provides a wide range and high-efficiency oxygen transmission rate detection for high, medium and low oxygen barrier materials.
coefficient of friction tester New advanced 0.01~0.999 film packaging COF GM-6 coefficient of friction tester GM-6
Coefficient of friction testers is used to test the coefficient of frictionof plastic film, thin sheet, paper and so on, widely used in packaging industry, film-making companies and packaging material inspection agencies.
  • Facebook
  • Linkedin
  • Youtube
  • Twitter

Copyright @ 2026 Guangzhou Biaoji Packaging Equipment Co.,Ltd. All Rights Reserved.

Chat now

Inquiry Now

Home

Products

NEWS

contact