packaging testing equipment Water Vapor Permeation Tester
Products
Home /

Breathability Series

/Carbon Paper Air Permeability Rate Tester

Carbon Paper Air Permeability Rate Tester

  • Item NO.:

    N600C
Inquiry now
Product Detail

Product Brief

The N600C Carbon Paper Air Permeability Rate Tester is designed and developed in accordance with GB/T 20042.7-2014. Adopting the differential pressure method as its testing principle, it is professionally used for measuring the air permeability rate of various types of carbon paper for proton exchange membrane fuel cells (PEMFC).

Testing Principle

Based on the differential pressure method, the sample is placed between two fixtures, forming a constant differential pressure on both sides of the sample. Driven by the differential pressure, gas flows from the high-pressure side through the sample to the low-pressure side. The air permeability rate of the carbon paper is calculated based on the transmission flow rate, sample thickness, test area, and test differential pressure.

Executed Standards

GB/T 20042.7-2014

Technical Parameters

Item Technical Parameters
Test Range 0~200,000 mL·mm/(cm²·h·mmHg)0~14,701 mL·mm/(cm²·hr·mmAq)
Resolution 0.1 mL·mm/(cm²·h·mmHg)0.1 mL·mm/(cm²·hr·mmAq)
Pressure Range 0~500 Pa (other ranges available upon request)
Pressure Resolution 0.1 Pa
Pressure Accuracy 0.1% FS (Full Scale)
Flow Range 0~50 L/min (other ranges available upon request)
Flow Resolution 1 mL/min
Flow Accuracy 1% FS (Full Scale)
Test Area 16 cm²
Instrument Dimensions 410 mm×295 mm×365 mm
Power 100 W
Power Supply 110~250 VAC, 50~60 Hz

Product Features

• The instrument's differential pressure is adjustable within the range of 0~500 Pa, with an accuracy of 0.1% FS, fully meeting the test pressure requirements of different samples;• The test range can be customized according to different sample requirements;• Arbitrary pressure adjustment, fully automatic operation, and automatic measurement and calculation of results;• Equipped with a color touch screen, no external computer required;• Built-in micro-printer for real-time printing of test reports;• The upper computer software is designed in accordance with the new GMP Appendix "Computerized Systems", supporting functions such as hierarchical permission management, audit trail, and electronic signature (optional).

 
Send A Message

Leave us a message, we will get back to you ASAP.

Related Products
Air Transmission Tester Air Permeability Analyzer for Textile- N900
N900 Air Permeability Analyzer to test the air permeability of many textile, including technical fabric, non-woven and breathable textile products.  
Professional Battery Separator Air Permeability Tester supplier Battery Separator Air Permeability Tester
Product Brief The N600E Battery Separator Air Permeability Tester is designed and developed in accordance with standards such as GB/T 36363-2018. Adopting the differential pressure method as its testing principle, it is professionally used for testing the air permeability of battery separators, breathable films, and related polymer materials. Testing Principle In an environment with controlled temperature, humidity, and normal pressure, the tester measures the time required for 100 mL of air to pass through a 6.45 cm² separator under an applied pressure of 1.21 kPa. Executed Standards GB/T 36363-2018, ISO 5636-5:2003, TAPPI T460 Technical Parameters Item Technical Parameters Test Range 60~12000 sec/100mL Resolution 0.1 sec/100mL Pressure Range 0~5 kPa Pressure Resolution 0.001 kPa Test Area 6.45 cm² Sample Size >50 mm×50 mm Instrument Dimensions 450 mm×400 mm×300 mm Power 100 W Power Supply 110~250 VAC, 50~60 Hz Product Features • The instrument's differential pressure is adjustable within the range of 0~5 kPa, with a precision of 0.001 kPa, fully meeting the test pressure requirements of different methods;• Supports multi-unit display (s/100mL and μm/(Pa·s));• The test range can be customized according to different sample requirements;• Excellent airtightness;• Arbitrary pressure adjustment, fully automatic operation, and automatic measurement and calculation of results;• Equipped with a color touch screen, no external computer required, enabling real-time observation of sample air permeability;• Built-in micro-printer for real-time printing of test reports;• The upper computer software is designed in accordance with the new GMP Appendix "Computerized Systems", supporting functions such as hierarchical permission management, audit trail, and electronic signature (optional).
Professional Paper & Paperboard Air Permeability Tester supplier Paper & Paperboard Air Permeability Tester
Product Brief The N600P Paper & Paperboard Air Permeability Tester is custom-developed to align with standards like GB/T 458-2008 and ISO 5636. It adopts the differential pressure method as its core testing principle, and innovatively integrates three industry-common testing approaches (Gurley, Schopper, and Bendtsen) into a single device.   This tester is applicable to air permeability detection of various paper and paperboard materials, and can measure key indicators including: material air permeability, air resistance, gas transmission rate, and total gas transmission volume. Testing Principle Gurley Method   Under a constant differential pressure of 1.23 kPa, measure the time required for 100 mL of gas to pass through the sample. Schopper Method   Select a suitable test duration under a constant differential pressure (1.00 kPa±0.01 kPa or 2.50±0.01 kPa), and calculate the gas flow rate through the sample by measuring the gas volume. Bendtsen Method   After clamping the sample for 5 seconds under a constant differential pressure of 1.47 kPa, test the gas flow rate through the surface of the sample. Executed Standards GB/T 458-2008, SJ/T 10171-2016, ISO 5636-5:2003, ISO 5636-2:1984, ISO 5636-3:2013, TAPPI T460 Technical Parameters   Item Technical Parameters Test Range 0.1~10 μm/(Pa·s) Resolution 0.001 μm/(Pa·s) Differential Pressure Range 0~5 kPa Pressure Resolution 0.001 kPa Test Area 6.42 cm² or 10.0 cm² Sample Size >50 mm×50 mm Instrument Dimensions (L×W×H) 450 mm×400 mm×300 mm Power 100 W Power Supply 110~250 VAC, 50~60 Hz
DSC Tester DSC100A DSC Testing Lab Differential Scanning Calorimeter
Product introduction:        DSC is the company's highest precision differential. The sensor is made of imported e-couple with high sensitivity.Signal acquisition circuit shielding protection, strong anti-interference, high baseline stability. The DSC is a touch screen type, which can be used for glass transition temperature test, phase transition test, melting and enthalpy test, product stability and oxidation induction period test.Wide range of application   Technical parameters: 1. Temperature range:Room temperature ~550 ℃ air cooling 2. Temperature resolution: 0.01℃ 3. Temperature fluctuation:±0.1℃ 4. Temperature repeatability:±0.1℃ 5. Heating rate: 0.1~100℃/min 6. Constant temperature time: program setting ≤ 24h 7. Temperature control mode: heating, constant temperature, 8. DSC range: 0~±600mW 9. DSC resolution: 0.01uW 10. DSC accuracy: 0.001mW 11. Working power supply: Ac220vv50 Hz or customized 12. Atmosphere control gas: nitrogen, oxygen (instrument automatic switch) 13. Gas flow: 0-300mllmin 14. Gas pressure: 0.2MPa 15. Display mode: 24 bit color, 7 inch LCD touch screen display 16. Data interface: standard USB interface 17. Parameter standard: With reference materials (indium, tin), users can adjust the temperature by themselves 18. The upper computer is a three in one operation software, which is also suitable for thermogravimetry and synchronous instruments. 19. The instrument has several groups of thermocouples, one for sample temperature, one for furnace body temperature and one for internal environment temperature Technical features: 1. Industrial level 7-inch touch screen, display information rich. 2. New metal furnace structure, better baseline and higher precision.Indirect conduction mode is adopted in heating, which has high uniformity and stability, and reduces pulse radiation, which is better than traditional heating mode. 3. USB communication interface, strong versatility, reliable communication, support self recovery connection function. 4. Automatic switching of two-way atmosphere flow, fast switching speed and short stable time.At the same time, a protective gas input is added. 5. The software is simple and easy to operate.
Vacuum Decay Leak Detection Tester Dual Pressure Methods Vacuum Decay Leak Detection Tester AUTO GBM-L2
Introduction AUTO GBM-L2 Dual-Pressure Methods Vacuum Decay Leak Detection Tester adopts the test principle of vacuum decay method/pressure decay to detect micro-leakage of finished packaging. It can be applied to packaging systems composed of vials, ampoules, Leakage detection of pre-filled needles, eye drop bottles, HDPE bottles, infusion bottles/bags and other pharmaceutical packaging, food packaging, and chemical industry packaging.   Test principle The host is connected to a sealed test chamber customized according to the sample. When performing the vacuum decay method test, the instrument evacuates the test chamber, and a pressure difference is formed inside and outside the sample. Under the action of the pressure, the gas/liquid in the sample enters the test chamber through the leak hole. The main engine uses the absolute pressure sensor and the differential pressure sensor to monitor the pressure change in the chamber to judge whether the sample leaks. When performing the pressure decay method test, the instrument fills the test chamber with a predetermined air pressure, and the gas in the test chamber enters the sample through the leak hole. The host uses absolute pressure sensors and differential pressure sensors to monitor the pressure changes in the chamber to determine whether the sample is leaking.   Standard ASTM F2338-2009(2013),  YY-T 0681.18-2020,  USP<1207.2>, ASTM F2095   Specification Item Parameters Absolute Pressure Testing Range (0 - 300) kPa Differential Pressure Testing Range (-2 - 2) kPa Detection Sensitivity 1 - 3 μm Balancing/Testing Time 1 - 3600 s Vacuum Purge Time 1 - 3600 s Set Flow Rate 0 - 3 mL/min Testing System Dual Sensor Technology/Dual Cycle Testing Testing Chamber Customized according to the sample Applicable Products Vials, Ampoules, Prefilled Syringes, Infusion Bottles/Bags, etc. Detection Principle Vacuum Decay Method/Pressure Decay Method Dimensions of the Main Unit 495 mm455 mm280 mm Ambient Temperature 20℃ - 25℃ Relative Humidity 40% - 60% Working Power Supply AC 220V, 50HZ   Features u Dual-Pressure Methods, to help solve testing difficulties The double combination of vacuum decay method and pressure decay method solves the problem of easy misjudgment and false negative for freeze-dried powder injections containing vacuum in the bottle using a single vacuum decay method. Based on dual-sensor and dual-circulation system technology, high-quality absolute pressure sensor and differential pressure sensor, with an accuracy of 0.1% FS, can effectively detect large and small leaks, accurately calculate the leak hole diameter, and give a pass or fail judgment.   The instrument has low sensitivity and good test repeatability For rigid samples, the detection sensitivity is as low as 1 μm, and the test repeatability is as low as 0.8%. The instrument has stable performance, low noise and good repeatability. u Imported brand accessories, excellent performance Imported brand vacuum pump, pumping rate up to 3 L/s, noise as low as 50 DB, high ultimate vacuum, convenient oil level detection and replacement. The imported gas mass flow controller can simulate micro-leaks arbitrarily, with a resolution of 0.001 mL/min, which provides a reliable guarantee for the method verification of instrument sensitivity. u Large size touch screen, intelligent operation Color 7-inch touch screen, clear view, sensitive touch, easy to operate. Equipped with a micro-printer, USB data interface, and supports PC software measurement and control operation. The test software is designed according to the GMP appendix "Computerized System". It has an audit trail function and multi-level authority settings for users, which can meet the needs of the pharmaceutical industry for data traceability. u Personalized customization to meet the needs of different samples For different test samples, it supports customization of suitable test chambers to meet the needs of different tests. For the same type of samples, it supports customized nesting mode, which can realize the sharing of a test chamber for samples of various specifications.   Application       Freeze-dried powder injection Injection Prefill needle       Eye drops Plastic Ampoule BFS Infusion bags   Factory configuration Standard Host machine, vacuum pump, test chamber and 3 sets of yin and yang control (customized as required), 11-inch touch panel, professional software (GMP) Optional Imported gas flow meters, air compressors, printers, calibration certificates  
COF tester GM-1 0-10N plastic film packaging coefficient of friction tester
The coefficient of friction tester is used to test the coefficient of frictionof plastic film, thin sheet, paper and so on, widely used in packaging industry, film-making companies and packaging material inspection agencies.
Thickness Tester Plastic Film Digital Thickness Tester
Didital thickness tester is used to make thickness measuring or comparative measuring of plastic film, thin sheet, paper and so on.
Ethylene Oxide Residuals Face Mask Ethylene Oxide (EO) Residuals Testing Gas Chromatography
GC9802-K Face Mask Ethylene Oxide (EO) Residuals Testing Gas Chromatography has a reasonable structure, stable and reliable performance, simple operation and convenient maintenance. Can be widely used in petroleum, chemical industry, pesticides, medicine and health, commodity inspection, environmental protection, universities and other production and scientific research departments. It can be used to detect ethylene oxide and other organic solvents. Detects purity or content of a single solvent
Thickness Tester Plastic Film Digital Thickness Tester
Didital thickness tester is used to make thickness measuring or comparative measuring of plastic film, thin sheet, paper and so on.
Heat Seal Strength Test Flexible Barrier Materials Heat Seal Strength Testing
Heat Seal Tester apply to test the temperature, pressure, time and strength for heat sealing of various plastic films, composite film, aluminum foil and so on, widely used in industries of , food, pharmaceuticals, inspection agency, research institute and so on.
Gas Permeation Tester Gas Permeability Analyzer for Testing Packaging Material GTR - N530
GBPI Gas Permeability Tester N530 demonstrate how to test gas volumn pass through your packaging material
spout insert and sealing machine Three-station Rotary Mode Spout Sealing Machine (Three-station)
Product introduction The automatic three-station rotary mode spout sealing machine is specially designed for automatic sleeving and heat sealing of straws and bags. It is suitable for straws of various calibers, lengths and models, and is the preferred automated equipment for spouted stand-up pouches in beverage packaging, drinkable jelly, condiments, and daily chemical products (laundry detergent, skin care products, etc.). It can be customized to connect with filling production lines.
  • Facebook
  • Linkedin
  • Youtube
  • Twitter

Copyright @ 2025 Guangzhou Biaoji Packaging Equipment Co.,Ltd. All Rights Reserved.

Chat now

Inquiry Now

Home

Products

NEWS

contact