Product Brief

The N600C Carbon Paper Air Permeability Rate Tester is designed and developed in accordance with GB/T 20042.7-2014. Adopting the differential pressure method as its testing principle, it is professionally used for measuring the air permeability rate of various types of carbon paper for proton exchange membrane fuel cells (PEMFC).

Testing Principle

Based on the differential pressure method, the sample is placed between two fixtures, forming a constant differential pressure on both sides of the sample. Driven by the differential pressure, gas flows from the high-pressure side through the sample to the low-pressure side. The air permeability rate of the carbon paper is calculated based on the transmission flow rate, sample thickness, test area, and test differential pressure.

Executed Standards

GB/T 20042.7-2014

Technical Parameters

Item Technical Parameters
Test Range 0~200,000 mL·mm/(cm²·h·mmHg)0~14,701 mL·mm/(cm²·hr·mmAq)
Resolution 0.1 mL·mm/(cm²·h·mmHg)0.1 mL·mm/(cm²·hr·mmAq)
Pressure Range 0~500 Pa (other ranges available upon request)
Pressure Resolution 0.1 Pa
Pressure Accuracy 0.1% FS (Full Scale)
Flow Range 0~50 L/min (other ranges available upon request)
Flow Resolution 1 mL/min
Flow Accuracy 1% FS (Full Scale)
Test Area 16 cm²
Instrument Dimensions 410 mm×295 mm×365 mm
Power 100 W
Power Supply 110~250 VAC, 50~60 Hz

Product Features

• The instrument's differential pressure is adjustable within the range of 0~500 Pa, with an accuracy of 0.1% FS, fully meeting the test pressure requirements of different samples;• The test range can be customized according to different sample requirements;• Arbitrary pressure adjustment, fully automatic operation, and automatic measurement and calculation of results;• Equipped with a color touch screen, no external computer required;• Built-in micro-printer for real-time printing of test reports;• The upper computer software is designed in accordance with the new GMP Appendix "Computerized Systems", supporting functions such as hierarchical permission management, audit trail, and electronic signature (optional).

 
Send A Message

Leave us a message, we will get back to you ASAP.

Related Products
Air Transmission Tester Air Permeability Analyzer for Textile- N900
N900 Air Permeability Analyzer to test the air permeability of many textile, including technical fabric, non-woven and breathable textile products.  
Professional Battery Separator Air Permeability Tester supplier Battery Separator Air Permeability Tester
Product Brief The N600E Battery Separator Air Permeability Tester is designed and developed in accordance with standards such as GB/T 36363-2018. Adopting the differential pressure method as its testing principle, it is professionally used for testing the air permeability of battery separators, breathable films, and related polymer materials. Testing Principle In an environment with controlled temperature, humidity, and normal pressure, the tester measures the time required for 100 mL of air to pass through a 6.45 cm² separator under an applied pressure of 1.21 kPa. Executed Standards GB/T 36363-2018, ISO 5636-5:2003, TAPPI T460 Technical Parameters Item Technical Parameters Test Range 60~12000 sec/100mL Resolution 0.1 sec/100mL Pressure Range 0~5 kPa Pressure Resolution 0.001 kPa Test Area 6.45 cm² Sample Size >50 mm×50 mm Instrument Dimensions 450 mm×400 mm×300 mm Power 100 W Power Supply 110~250 VAC, 50~60 Hz Product Features • The instrument's differential pressure is adjustable within the range of 0~5 kPa, with a precision of 0.001 kPa, fully meeting the test pressure requirements of different methods;• Supports multi-unit display (s/100mL and μm/(Pa·s));• The test range can be customized according to different sample requirements;• Excellent airtightness;• Arbitrary pressure adjustment, fully automatic operation, and automatic measurement and calculation of results;• Equipped with a color touch screen, no external computer required, enabling real-time observation of sample air permeability;• Built-in micro-printer for real-time printing of test reports;• The upper computer software is designed in accordance with the new GMP Appendix "Computerized Systems", supporting functions such as hierarchical permission management, audit trail, and electronic signature (optional).
Professional Paper & Paperboard Air Permeability Tester supplier Paper & Paperboard Air Permeability Tester
Product Brief The N600P Paper & Paperboard Air Permeability Tester is custom-developed to align with standards like GB/T 458-2008 and ISO 5636. It adopts the differential pressure method as its core testing principle, and innovatively integrates three industry-common testing approaches (Gurley, Schopper, and Bendtsen) into a single device.   This tester is applicable to air permeability detection of various paper and paperboard materials, and can measure key indicators including: material air permeability, air resistance, gas transmission rate, and total gas transmission volume. Testing Principle Gurley Method   Under a constant differential pressure of 1.23 kPa, measure the time required for 100 mL of gas to pass through the sample. Schopper Method   Select a suitable test duration under a constant differential pressure (1.00 kPa±0.01 kPa or 2.50±0.01 kPa), and calculate the gas flow rate through the sample by measuring the gas volume. Bendtsen Method   After clamping the sample for 5 seconds under a constant differential pressure of 1.47 kPa, test the gas flow rate through the surface of the sample. Executed Standards GB/T 458-2008, SJ/T 10171-2016, ISO 5636-5:2003, ISO 5636-2:1984, ISO 5636-3:2013, TAPPI T460 Technical Parameters   Item Technical Parameters Test Range 0.1~10 μm/(Pa·s) Resolution 0.001 μm/(Pa·s) Differential Pressure Range 0~5 kPa Pressure Resolution 0.001 kPa Test Area 6.42 cm² or 10.0 cm² Sample Size >50 mm×50 mm Instrument Dimensions (L×W×H) 450 mm×400 mm×300 mm Power 100 W Power Supply 110~250 VAC, 50~60 Hz
Crush Tester Crush Tester Paper Packaging Test Equipment
Paper Packaging Test Equipment 
Oxygen Permeability Analyzer Y310 2.0 Gas Analysis Equipment Oxygen Permeability Analyzer
This product is based on the test principle of the Coulomb oxygen analysis sensor and is designed and manufactured with reference to the ASTM D 3985 standard. It is used to determine the oxygen transmission rate (quantity) of film or sheet materials.
Compression Resistance Tester Compression Tester for Bag Packaging GBN200A
The Compression Tester GBN200A is professionally used to test the pressure resistance and burst resistance of various packaging bags. It can set the pressure and measure the deformation; set the deformation and measure the pressure resistance. It is an ideal testing equipment for quality inspection, drug inspection, scientific research, packaging, film, food, medicine, daily chemical and other industries.
Elmendorf tearing strength tester GBD-S ASTMD689 Elmendorf Tearing Strength Tester For Fabric And Paper
The tear tester (elemendorf method) tests the tear resistance of paper, film, PVC, polyolefin, polyester, composite film, sheet, non-woven fabric, textile, paper, and board, etc. It is controlled by computer automatically and can be tested independently.
1 GBPI ASTM D 3078 hermetic sealing quality test electronic leakage tester GB-M1
GBPI Electronic Leakage Tester Application: To test the hermetic sealing quality and performance of packaging bags, bottles, cans and so on, used in industries of food, beverage, pharmaceuticals, personal care and so on.
Oxygen Gas Permeability Tester Oxygen Permeability Analyzer - Coulometric Sensor Method
This product is based on the testing principle of the coulometric sensor method testing Oxygen, and is designed and manufactured with reference to ASTM D3985 and other standards. Adopting high-precision imported oxygen sensor, high test accuracy,it is suitable for oxygen transmission performance testing of films, sheets, paper, packaging and related materials in the fields of food, medicine, medical equipment, daily chemicals, photovoltaic electronics, etc., and provides a wide range and high-efficiency oxygen transmission rate detection for high, medium and low oxygen barrier materials.
Professional Paper & Paperboard Air Permeability Tester supplier Paper & Paperboard Air Permeability Tester
Product Brief The N600P Paper & Paperboard Air Permeability Tester is custom-developed to align with standards like GB/T 458-2008 and ISO 5636. It adopts the differential pressure method as its core testing principle, and innovatively integrates three industry-common testing approaches (Gurley, Schopper, and Bendtsen) into a single device.   This tester is applicable to air permeability detection of various paper and paperboard materials, and can measure key indicators including: material air permeability, air resistance, gas transmission rate, and total gas transmission volume. Testing Principle Gurley Method   Under a constant differential pressure of 1.23 kPa, measure the time required for 100 mL of gas to pass through the sample. Schopper Method   Select a suitable test duration under a constant differential pressure (1.00 kPa±0.01 kPa or 2.50±0.01 kPa), and calculate the gas flow rate through the sample by measuring the gas volume. Bendtsen Method   After clamping the sample for 5 seconds under a constant differential pressure of 1.47 kPa, test the gas flow rate through the surface of the sample. Executed Standards GB/T 458-2008, SJ/T 10171-2016, ISO 5636-5:2003, ISO 5636-2:1984, ISO 5636-3:2013, TAPPI T460 Technical Parameters   Item Technical Parameters Test Range 0.1~10 μm/(Pa·s) Resolution 0.001 μm/(Pa·s) Differential Pressure Range 0~5 kPa Pressure Resolution 0.001 kPa Test Area 6.42 cm² or 10.0 cm² Sample Size >50 mm×50 mm Instrument Dimensions (L×W×H) 450 mm×400 mm×300 mm Power 100 W Power Supply 110~250 VAC, 50~60 Hz
Salt Spray Tester Salt spray test chamber GB-OSH-60
  1. FunFunction Salt spray test chamber is used for the quality inspection and corrosion resistance test of a variety of materials, including metal plating, metal, electronic components, chemical coatings, paint, automobiles, motorcycles, metal ware, screws, springs, magnetic materials, organic and inorganic coating, anodizing, anti-rust oil industry etc. after the surface treatment.   1. ecGTechnical parameters   1. MODEL GB-OSH-60 2. Temperature inside chamber 35℃±1℃/ 50℃±1℃ 3. Temperature of pressure barrel 47℃±1℃/ 63℃±1℃  4. Inner size W600 x H400 x D450mm   5. External size W1080 x H1080 x D650mm 6. Temperature Uniformity ≤±2℃ 7. Uniformity Fluctuation ≤±0.5℃ 8. Salt fog settlement 1~2ml/h.80cm2 9. Compressed air pressure 1.00±0.01kgf/cm² 10. Spray mode Continuous or intermittent spray optional 11. Power supply AC  220V   50Hz   1.5KW a)  Temp. range: RT+10℃ ~ 55℃ (temperature up to 50C, thickening PVC or PP material is recommended ) b) Humid. range: ≥93%R.H c) Controller time shown: 9.9s~9990hrs d) Timer: 0~9999hrs. e) Testing method: Neutral salt spray test (NSS test), acetic acid salt spray test (AASS test), salt spray test (SS test), copper accelerated acetic acid salt spray test method for salt spray test (CASS test) and so on; (For CASS test, we recommend the PP material chamber with high temperature resistance) f) Specimen holder: It can meet the tilt test at 15 ℃ ~ 30 ℃ (two layers); g) Air compressor: V-0.013/12.5(Customer provided); discharge pressure:1.25M; flow amount: 0.13m3/min   1. MMMaterial of machine body a) Salt spray chamber adopts the quality PVC reinforced hard plastic plate, the surface is smooth and anti-aging, anti-corrosion; b) Without any FRP material produced on the surface because of discoloration fibrosis. Plastic structure of the chamber is better to meet strong acid salt spray test under long-term without any damage. c) Cover is imported transparent impact-resistant plate which is convenient to test specimen when test, that can cover and the box with a water seal to prevent leakage of salt spray.   2. AccAccording to CSN, JIS, ASTM standards, can be set to constant temperature control: (a) Brine spray test: NSS (neutral); · Temp. inside chamber: 35 ℃ ± 1 ℃ · Pressure air bucket: 47 ℃ ± 1 ℃ (b) Corrosion resistance test: CASS (copper acceleration), AASS (acid) · Temp. inside chamber: 50 ° C ± 1 ° C · Pressure air bucket: 63 ℃ ± 1 ℃   3. Watwatering system. It adopts the auto watering system, supply water when lack of water. 4. HeaHeating system Test temperature inside the cabinets is heated humidification water jacket, the heater adopts advanced titanium protective tube, built-in nickel-chromium alloy infrared heater core. Heating up fast, uniform temperature distribution; and saves about one half of the power compared to FRP tank jacketed heating. 5. ExeExecutive standard GB/T 2423.17 Basic test procedures for electric and electronic products Ka"- salt spray test methods; GB/T 10125 Corrosion tests in artificial atmospheres – salt spray tests; ASTM B368 Test Method for Copper-Accelerated Acetic Acid-Salt Spray (Fog) Testing (CASS Test); JIS Z2371-2000 Methods of salt spray testing etc. ISO 9227 Corrosion tests in artificial atmospheres (Note: 2 collection device is required, bigger models than ZH-SH-90 (270L) is required; In some versions, it specifies over 400liters is necessary)  ASTM B117-18 Standard Practice for Operating Salt Spray (Fog) Apparatus (Note: 2 collection device is required, bigger models than ZH-SH-90 is required )  
COF Testing Flexible Packaging Film Coefficient of Friction Tester COF Testing
The Coefficient of Friction Tester equipment performs tests to most of the recognised international test standards including IS0 8295 and ASTM 1894-78.