packaging testing equipment Water Vapor Permeation Tester
Products
Home /

Chemical Properties Test Equipment

/

Migration Test for Plastic

/GBPI Migration Testing equipemnent In Food Plastic Packaging Migration & Non-volatile-matter Content Tester

GBPI Migration Testing equipemnent In Food Plastic Packaging Migration & Non-volatile-matter Content Tester

 

ZF3600 Full-automatic Total Migration Tester is applied to determinate the dissolution amount of packaging materials in different simulant soaking solutions.

 
  • Item NO.:

    ZF3600
  • Shipping Port:

    SHENZHEN
Inquiry now
Product Detail

 

1) Tableware, cans, food packaging films, tubes, etc.

2) Made from polyethylene (PE), polystyrene (PS), polypropylene (PP) or chlorinated polyvinyl chloride (CPVC).

 

Evaporate and dry the soaking solutions to obtain residues migrated from the specimen. The residues analysis and weighing refer to dissolution indexes in application requirements of packaging products.

 

Standard

 GB 31604.8-2016, GB/T 9740-2008, GB/T 5009.156-2016, GB/T 5009.156-2016, YBB00342002-2015, YBB00102005-2015, YBB00082002-2015.

 

Specifications

 

Item Technical Parameters
Measurement Range 0 g~80 g
Balance Resolution 0.01 mg
Balance Capacity 0 g~220 g
Constant Weight Error 0.3 mg (Adjustable)
Water Bath Temperature Range Room temperature~100℃
Heating Chamber Temperature Range Room temperature~125℃
Temperature Control Accuracy ±0.5℃
Number of Specimens 36
Evaporating Dish Capacity 100 ml
Air Source Interface Size Φ8 mm
Equipment Dimensions 1200 mm (L)×850 mm (W)×1335 mm (H)
Power Supply 220V, 50Hz
Rated Power 7000 W
Operating System Windows 10 Professional 64-bit
 

 

 
Send A Message

Leave us a message, we will get back to you ASAP.

Related Products
migration tester ZF1800A Full-automatic Total Migration Tester
full-automatic migration tester is specialized for testing dissolved non-volatile-matter of materials after soaked in specific solution.
migration testing in food packaging Fully Automatic Overall Migration Tester-ZF900
Full-Automatic Overall Migration Tester AUTO ZF900 has an integrated system design of water bath evaporation, heating and drying, drying and cooling, and constant temperature weighing. It is suitable for testing the total migration (non-volatile matter, evaporation residue) and other items in the fields of purified water, pharmaceutical packaging materials, food packaging, cigarette tipping paper and chemical reagents. It can also be applied to the water content, loss on drying and other items of solid samples, and the total dissolved solids content test in water quality testing.
migration tester Full-automatic Total Migration Tester -AUTO ZF1800G
Full-automatic Total Migration Tester AUTO ZF1800G has an integrated system design of water bath evaporation, heating, drying, cooling, and constant temperature weighing. The testing process is fully automated without manual operation. It is suitable for testing the overrall migration (non-volatile matter, evaporation residue) and other items in the fields of purified water, pharmaceutical packaging materials, food packaging, cigarette tipping paper and chemical reagents. It can also be applied to the water content, loss on drying and other items of solid samples, and the total dissolved solid content test in water quality testing.
Falling Dart Impact Tester Falling Dart Impact Tester Test Plastic film Sheet Flexible Package GBD-L
GBD-L Falling Dart Impact Tester test the impact resistance of various films, metallic foil and so on, widely used in industries of packaging, plastic films, laboratory, research institute, inspection agency and so on.
Leakage Tester Plastic Bags Electronic Leakage Tester GB- M2
Electronic Leakage Tester applies to test the hermetic sealing quality and performance of packaging bags, bottles, cans and so on, used in industries of food, beverage, pharmaceuticals, personal care and so on          
Vertical Heat Seal Tester Vertical Heat Seal Tester GBB-C
Product Introduction GBB-C vertical heat seal tester can accurately measure the heat sealing temperature, heat sealing time, heat sealing pressure, and other heat sealing performance parameters of plastic packaging vertical bags, paper-plastic composite vertical bags and metal composite vertical bags(boxes). The heat sealing performance of samples of different materials are different. And the best heat sealing conditions can be accurately obtained through the determination of their heat sealing performance parameters.   Testing Principle Put the sample on the lower tray of the instrument, adjust the appropriate height according to the size of the sample, set a certain sealing temperature, time and pressure as required, and start the instrument with one key. The fixture on the instrument will heat seal the sample according to the setting parameters. Under the manual state, step on the foot switch, and the heat sealing knife is pressed. The heat sealing time is determined by the value set by the time control. In the automatic state, the upper and lower heat sealing knives of the heat sealer will automatically heat seal repeatedly according to the set time. Standards ASTM F 2029 Specifications Item  Technical Parameters Temperature Range Room temperature ~ 250℃ Temperature Control Accuracy ±1℃ Hot Sealing Time 0.1s ~ 99.99 h Hot Sealing Pressure (0~1) MPa Hot Sealing Surface Upper and lower sealing knives: 300×5.5 mm, smooth; lower sealing bar with silicon pad Operation Mode Two modes: automatic and manual, with external cylinder Gas Source Compressed air Overall Dimensions 730(L) mm×400(B) mm×535(H) mm Weight 33.8kg Power 1200 W Power Supply AC 220V, 50Hz     Characteristics u High progress imported quality sensor, quality assurance Original imported temperature sensor, wide temperature control range, high sensitivity, temperature control accuracy of ± 1 ℃, it has ultra-high stability and ultra-low failure rate. u Independent control of heat sealing temperature The rear of the heat sealing knife is equipped with a temperature sensor, and the temperature control of the inner and outer sealing knives is independent and set separately. u Personalized test selection Manual testing and automatic testing are free to choose. The automatic mode is time-saving and convenient, and the repeatability is fully automatic for heat-sealing the sample; the manual mode is equipped with a suitable foot switch, step on the foot switch, the heat sealing knife is pressed, and the safety protection is easy to operate. u New air drive system The drive system consists of a pressure gauge, a pressure regulating valve, and a cylinder. After the compressed air is introduced, the pressure is adjusted through the pressure valve, the air pressure can be accurately locked, and the heat sealing clamp is pneumatically driven, which is convenient and efficient. u Wider range of customized services The anti-sticking function of the heat sealing knife can be upgraded as needed, experience upgrade, and it is more intuitive and convenient to determine the best heat sealing conditions. The shape, size and smoothness of the sealing knife heat cover can be customized to meet different scientific research needs.   Application     Plastic stand up pouch Paper plastic stand up pouch     Aluminized stand up pouch Milk Boxes  
Atmosphere Refrigerator AUTO GQ100 Modified Atmosphere Refrigerator
  The AUTO GQ-100 Modified Atmosphere Refrigerator is meticulously engineered for storage and preservation tests of diverse fruits, vegetables, flowers, seedlings, and more. By harnessing microelectronics technology, it automatically regulates the concentrations of oxygen, nitrogen, carbon dioxide, and ethylene inside the refrigerator, along with temperature and humidity conditions, to achieve outstanding preservation effects. It is an essential and perfect equipment for microbiology, environmental protection, food production, universities, research institutions, and other relevant organizations.   Technical Parameters Project Technical Parameter Gas Measurement Range O₂: 0%–30%; CO₂: 0%–20%; C₂H₄: 0–220 ppm; Remaining gas: N₂ Gas Testing Accuracy O₂: 0.01%; CO₂: 0.01%; C₂H₄: 0.1 ppm Gas Purity Requirement Purity of O₂, CO₂, N₂, and C₂H₄ ≥ 99.9% Gas Flow Control O₂: 0–500 mL/min; CO₂: 0–500 mL/min; N₂: 0–500 mL/min Temperature Control Range -5°C–45°C Chamber Temperature Control Accuracy ±0.5°C Chamber Humidity Range Normal–95% RH Humidity Fluctuation Range ±3% RH Cooling Capacity 1 HP Chamber Humidifier Power 50 W Chamber Lighting System Power 10 W Material Colored steel plate Dimensions 889 mm × 1285 mm × 1750 mm Total Machine Power 1 KW Number/Volume of Test Chambers 1 chamber/100 L Power Supply AC 220V   Application   Fruit and vegetable storage and preservation It is suitable for the storage and preservation test of various domestic and imported fruits and vegetables.   Storage and preservation of meat and seafood It is suitable for storage and preservation test of various pork, beef, mutton and other meat and seafood products such as fish, shrimp, crab, etc.   Baked food storage and preservation It is suitable for the storage and preservation test of various bakery products such as bread, cakes and biscuits.   Storage and preservation of flowers and seedlings It is suitable for the storage and preservation test of various roses, lilies, phalaenopsis and other flowers and seedlings.   Product features Three test chambers work independently; Each chamber has its own humidity, flow and concentration of various gases, ethylene removal devices, lighting systems, sterilization systems, and drainage systems.  Built-in microcomputer system, automatic control, and automatic processing of data. Manually switch the cavity to display the temperature and humidity of each cavity, as well as the concentration of oxygen, nitrogen, carbon dioxide, ethylene, and so on.   24 inch 100,000 real color touch screen, can set the parameters of each cavity and control operations respectively; Detailed data and work status are displayed in real time.  Built-in ozone sterilization, manual button sterilization, can set the sterilization time.  Built-in ethylene catalytic removal device and gas displacement pump control ethylene concentration, fast degassing speed.  Imported high-precision sensors to detect various gas concentrations and ethylene concentrations. The sterilization system adopts ozone sterilization, the manual button for sterilization, automatic control of sterilization time, and automatic stop when the set time is reached. Temperature control: using heating wire heating, scroll compressor cooling, stable performance, low noise; PID algorithm with solid state relay control, no hard mechanical contacts, long service life, average temperature heating, constant temperature. The temperature control of each chamber adopts unified control, and the temperature of the three chambers is set manually. Humidity control: high-frequency atomization humidification, the humidification range is large, long-term humidification does not heat, does not affect the cavity temperature; Each chamber humidification system operates independently, automatically humidifies and maintains humidity after setting the humidity. The inner wall of each cavity is made of stainless steel, the special double-layer glass door, and the shell is made of special color steel plate.  Transparent windows, drainage system anti-condensation, built-in lighting, and self-entry box design.
Ozone Aging Test Chamber Ozone Aging Test Chamber (Dynamic Stretching) GB-OCY-150M
1 Function Ozone in the atmosphere is very little, while it’s a major factor in rubber cracking, the product simulate and enhance atmospheric ozone condition to study the role of ozone on the rubber, and to rapid identificate and evaluate rubber resistance for ozone aging and anti-ozone agent protection. According to“GB / T7762-2003 Test Method for Static Tensile Test of Ozone Resistance Cured Rubber or Thermoplastic Rubber”,“GB / T2951.21-2008 General Test Method for Insulation and Sheathing Material of Cable”,“GB / T 11206-2009 Rubber Aging test surface cracking method”, and other relevant standards of the test method. 2.1 Structure  All-in-one machine 2.2 Material a) Inner chamber: SUS304 stainless steel plate b) External chamber: SUS304 stainless steel plate or baking finish. Insulation: rigid polyurethane foam + aluminum insulation cotton with double protection. 2.3 Machine door a) Single door, open from left. b) Window frame / door frame with two silicone rubber seal and anti-condensation heating device. c)With observation window (W220xH250mm), lights above the window and door.  2.4 Requirements for sample holder (for dynamic-type only)       a)At both ends of the sample to be fixed with a clamp under the required elongation, the longitudinal direction of the specimen shall be substantially parallel to the direction of air flow when in contact with ozonized air. b) Clamps shall be made of a material (eg aluminum) which does not readily decompose ozone. c) Allow the sample to rotate at a speed between (20 ^ -25) mm / s, in a plane perpendicular to the dry gas flow, with each sample moving continuously along the same path. d) The time of one revolution of the same specimen is (8 ^ -12) min. The scanning area of the specimen shall be at least 40% of the effective area of the test chamber. Specimen preparation shall conform to the provisions of GB / T 9865.1. The test specimen is preferably cut from the new test piece and, if desired, may be cut from the finished product. At least 3 specimens shall be required for per test condition. The standard length of the specimen is not less than 10mm, and thickness not less than 0.2mm. The length of specimen between the two ends of the clamp before drawing is not less than 40mm. 3 Control panel a) Controller display b) Power switch c) Fault alarm d)Wavelength switch e)light switch button 4 Enclosure configuration a) With a stainless steel SUS # 304 shelf turntable b) One φ50mm lead hole:, and with a hole cover and silicone rubber plug. c) Move casters 4 pcs d) Horizontal mounting brackets 4 pcs e) There is a drainage hole in the back of the machine to facilitate the drainage of condensate; (8mm in diameter) Three-phase five-wire cable (four-core cable + protective grounding wire) 1 pc, (three meters long).
coefficient of friction tester New advanced 0.01~0.999 film packaging COF GM-6 coefficient of friction tester GM-6
Coefficient of friction testers is used to test the coefficient of frictionof plastic film, thin sheet, paper and so on, widely used in packaging industry, film-making companies and packaging material inspection agencies.
Ethylene Oxide Residuals Face Mask Ethylene Oxide (EO) Residuals Testing Gas Chromatography
GC9802-K Face Mask Ethylene Oxide (EO) Residuals Testing Gas Chromatography has a reasonable structure, stable and reliable performance, simple operation and convenient maintenance. Can be widely used in petroleum, chemical industry, pesticides, medicine and health, commodity inspection, environmental protection, universities and other production and scientific research departments. It can be used to detect ethylene oxide and other organic solvents. Detects purity or content of a single solvent
PCT test chamber PCT Test Chamber Pressure Cooker test chamber GB-OPCT-30
1.Function It’s widely used in rubber products, magnetic materials, circuit boards, muti-layer circuit boards, IC, LCD, electronics and other products sealing performance testing.   2.Characteristics 1) The imported double-temperature structure with high temperature resistant solenoid valve is used to minimize the failure rate. 2) Independent steam generation chamber to avoid direct impact of steam on the product, so as not to cause partial damage to the product. 3) The door lock labor-saving structure solves the shortcomings of the locking difficulty of the first-generation product disc handle. 4) Cool air before the test; the design of the exhaust air in the test (air discharge in the test barrel) improves the pressure stability and reproduction. 5) Ultra long-term experimental running time up to 400 hours. 6) Water level protection, through the test room water level Sensor to detect protection. 7) Tank with anti-pressure design, the box body with pressure (150 ° C) up to 2.65kg, in line with the water pressure test of 6kg. 8) Two-stage pressure safety protection device, adopting two-stage combined controller and mechanical pressure protection device. 9) Safety protection pressure button, two-stage automatic pressure button for emergency safety device. 10) Bias test terminal withstand voltage up to 3000V (optional) 11) USB for exporting the history data, curve. 3.Technical parameters 1)Temperature range: +100°C~+132°C (Saturated vapor temperature) 2)Humidity Range: 100% steam Humidity 3)Humidity Control Stability: ±1%RH 4)Working pressure: 1.2~2.89kg/cm2 (including 1atm) 5)Time Range: 0 Hr to 999 Hr 6)Pressurization time: 0.00 Kg ~ 1.04 Kg/cm2 about 45 minutes 4.Material of chamber 1)Test chamber size:∮300 mm x L500 mm; 2)Overall size: W900x D900 x H1400 mm; 3)Inner barrel material: Stainless steel plate material (SUS# 316, 3mm); 4)Outer barrel material: stainless steel plate material or spray plastic; 5)Insulation material: rock wool and hard polyurethane foam insulation 6)Steam chamber heating tube: Titanium tube is heated and never rusts. 7)Control System: Taiwan-made Delta color touch PLC to control humidity and steam temperature (using PT-100 Platinum temperature sensor). (Imported large-screen touch controller) 5.Mechanical structure 1)Round inner box, stainless steel round test inner box structure, in line with industrial safety container standards, can prevent dew condensation design during test. 2)Round lining, stainless steel circular lining design, can avoid direct impact of vapor latent heat on the sample. 3)Precision design, good air tightness, low water consumption, and can be operated continuously for 400Hrs every time. 4)The patented packing design makes the door and the box more tightly combined, which is completely different from the traditional extrusion type, and can extend the packing life. 5)Critical point LIMIT mode automatic safety protection, abnormal cause and fault indicator display. 6)Security Protection: a)Imported high temperature sealed solenoid valve adopts double circuit structure to ensure no leakage of pressure. b)The whole machine is equipped with over-pressure protection, over-temperature protection, one-button pressure relief, manual pressure relief and multiple safety guarantee devices to ensure users to the greatest extent. c)Use and safety. d)Back pressure door lock device, the test box door cannot be opened when there is pressure inside the test chamber. 6.Other accessories. 1)Test rack 1 group 2)Sample tray   7.Ambient environment & Facilities. 1)It can be allowed to use the working environment temperature 5 ° C ~ 30 ° C; experimental water: pure water or distilled water 2)System power fluctuations should not be greater than ± 10, 220V 20A.    
  • Facebook
  • Linkedin
  • Youtube
  • Twitter

Copyright @ 2026 Guangzhou Biaoji Packaging Equipment Co.,Ltd. All Rights Reserved.

Chat now

Inquiry Now

Home

Products

NEWS

contact