packaging testing equipment Water Vapor Permeation Tester
Products
Home /

Flexible Packaging Testing Service

/

Testing Items

/

coefficient of friction test

/Flexible Packaging Film Coefficient of Friction Tester COF Testing

Flexible Packaging Film Coefficient of Friction Tester COF Testing

The Coefficient of Friction Tester equipment performs tests to most of the recognised international test standards including IS0 8295 and ASTM 1894-78.

  • Brand:

    GBPI
  • Item NO.:

    GM-4 Coefficient of
  • Product Origin:

    Guangzhou China
  • Shipping Port:

    Huangpu Guangzhou
Inquiry now
Product Detail

With the improvement of people's living standards, consumers have higher demands on the quality of food, clothing, food, beverages, medicines, automobiles and other products, because the quality of their products is closely related to people's lives. It has become the focus of attention of many enterprises and consumers. Among them, material quality control is an important aspect of product quality. In order to make material suppliers have a clear understanding of the quality of their own products, Guangzhou Standard International provides sample commissioned testing services to the community.



Coefficient of Friction. ASTM D1894 is a testing standard designed to measure the friction of plastic film and sheeting. This test method measures the initial and moving friction of one material being dragged across another, otherwise known as the static (initial) and kinetic (moving) coefficients of friction (COF).



GBPI GM-4 Coefficient of Friction Tester is used to test the smoothness, evenness and sealing strength of plastic film, paper and other materials, used in packaging industry, membrane industry, inspection agency and so on.


1. Core part is imported, with high performance, stability and accuracy, and durable.

2. Easy to operate, software controlled, can connect to computer and display curves and print report.

3. Infinitely variable speeds setting.


Send A Message

Leave us a message, we will get back to you ASAP.

Related Products
Gas Permeation Tester Gas Permeability Analyzer for Testing Packaging Material GTR - N530
GBPI Gas Permeability Tester N530 demonstrate how to test gas volumn pass through your packaging material
UV lamp aging test chamber UV lamp aging test chamber GB-OUVA-115
Accelerated weathering tests are performed on materials by simulating ultraviolet radiation and condensation in natural sunlight to obtain results on material weathering resistance. It can simulate environmental conditions such as ultraviolet, rain, high temperature, high humidity, condensation, and darkness in natural climates. By reproducing these conditions, it can be combined into a cycle and allowed to automatically complete the cycle as required.
Vacuum Decay Leak Detection Tester Dual Pressure Methods Vacuum Decay Leak Detection Tester AUTO GBM-L2
Introduction AUTO GBM-L2 Dual-Pressure Methods Vacuum Decay Leak Detection Tester adopts the test principle of vacuum decay method/pressure decay to detect micro-leakage of finished packaging. It can be applied to packaging systems composed of vials, ampoules, Leakage detection of pre-filled needles, eye drop bottles, HDPE bottles, infusion bottles/bags and other pharmaceutical packaging, food packaging, and chemical industry packaging.   Test principle The host is connected to a sealed test chamber customized according to the sample. When performing the vacuum decay method test, the instrument evacuates the test chamber, and a pressure difference is formed inside and outside the sample. Under the action of the pressure, the gas/liquid in the sample enters the test chamber through the leak hole. The main engine uses the absolute pressure sensor and the differential pressure sensor to monitor the pressure change in the chamber to judge whether the sample leaks. When performing the pressure decay method test, the instrument fills the test chamber with a predetermined air pressure, and the gas in the test chamber enters the sample through the leak hole. The host uses absolute pressure sensors and differential pressure sensors to monitor the pressure changes in the chamber to determine whether the sample is leaking.   Standard ASTM F2338-2009(2013),  YY-T 0681.18-2020,  USP<1207.2>, ASTM F2095   Specification Item Parameters Absolute Pressure Testing Range (0 - 300) kPa Differential Pressure Testing Range (-2 - 2) kPa Detection Sensitivity 1 - 3 μm Balancing/Testing Time 1 - 3600 s Vacuum Purge Time 1 - 3600 s Set Flow Rate 0 - 3 mL/min Testing System Dual Sensor Technology/Dual Cycle Testing Testing Chamber Customized according to the sample Applicable Products Vials, Ampoules, Prefilled Syringes, Infusion Bottles/Bags, etc. Detection Principle Vacuum Decay Method/Pressure Decay Method Dimensions of the Main Unit 495 mm455 mm280 mm Ambient Temperature 20℃ - 25℃ Relative Humidity 40% - 60% Working Power Supply AC 220V, 50HZ   Features u Dual-Pressure Methods, to help solve testing difficulties The double combination of vacuum decay method and pressure decay method solves the problem of easy misjudgment and false negative for freeze-dried powder injections containing vacuum in the bottle using a single vacuum decay method. Based on dual-sensor and dual-circulation system technology, high-quality absolute pressure sensor and differential pressure sensor, with an accuracy of 0.1% FS, can effectively detect large and small leaks, accurately calculate the leak hole diameter, and give a pass or fail judgment.   The instrument has low sensitivity and good test repeatability For rigid samples, the detection sensitivity is as low as 1 μm, and the test repeatability is as low as 0.8%. The instrument has stable performance, low noise and good repeatability. u Imported brand accessories, excellent performance Imported brand vacuum pump, pumping rate up to 3 L/s, noise as low as 50 DB, high ultimate vacuum, convenient oil level detection and replacement. The imported gas mass flow controller can simulate micro-leaks arbitrarily, with a resolution of 0.001 mL/min, which provides a reliable guarantee for the method verification of instrument sensitivity. u Large size touch screen, intelligent operation Color 7-inch touch screen, clear view, sensitive touch, easy to operate. Equipped with a micro-printer, USB data interface, and supports PC software measurement and control operation. The test software is designed according to the GMP appendix "Computerized System". It has an audit trail function and multi-level authority settings for users, which can meet the needs of the pharmaceutical industry for data traceability. u Personalized customization to meet the needs of different samples For different test samples, it supports customization of suitable test chambers to meet the needs of different tests. For the same type of samples, it supports customized nesting mode, which can realize the sharing of a test chamber for samples of various specifications.   Application       Freeze-dried powder injection Injection Prefill needle       Eye drops Plastic Ampoule BFS Infusion bags   Factory configuration Standard Host machine, vacuum pump, test chamber and 3 sets of yin and yang control (customized as required), 11-inch touch panel, professional software (GMP) Optional Imported gas flow meters, air compressors, printers, calibration certificates  
Moisture permeation rate tester Water Vapor Permeability Analyzer For LDPE Film Gravimetric Method - W533
A533 water vapor permeability analyzer is to test the water vapor transmission rate (WVTR) of films or sheets materials.
Compression Strength Tester BCT (Box Compression Test) Packaging Burst Compression Strength Tester GBN2000Z
This machine is used to test the compression, deformation resistance and stacking of corrugated carton, honeycomb board box and so on.
Atmosphere Refrigerator AUTO GQ300 Modified Atmosphere Refrigerator
AUTO GQ-300 Modified Atmosphere Refrigerator is mainly for a variety of fruits, vegetables, flowers, seedlings, etc. on the market for storage and preservation tests, through microelectronics technology to automatically control the concentration of oxygen, nitrogen, carbon dioxide, ethylene in the box, as well as control temperature, humidity conditions to achieve the preservation effect, is a microorganism, environmental protection, food production, universities, scientific research institutions and other units indispensable ideal equipment.  
Salt Spray Tester Salt spray test chamber GB-OSH-60
  1. FunFunction Salt spray test chamber is used for the quality inspection and corrosion resistance test of a variety of materials, including metal plating, metal, electronic components, chemical coatings, paint, automobiles, motorcycles, metal ware, screws, springs, magnetic materials, organic and inorganic coating, anodizing, anti-rust oil industry etc. after the surface treatment.   1. ecGTechnical parameters   1. MODEL GB-OSH-60 2. Temperature inside chamber 35℃±1℃/ 50℃±1℃ 3. Temperature of pressure barrel 47℃±1℃/ 63℃±1℃  4. Inner size W600 x H400 x D450mm   5. External size W1080 x H1080 x D650mm 6. Temperature Uniformity ≤±2℃ 7. Uniformity Fluctuation ≤±0.5℃ 8. Salt fog settlement 1~2ml/h.80cm2 9. Compressed air pressure 1.00±0.01kgf/cm² 10. Spray mode Continuous or intermittent spray optional 11. Power supply AC  220V   50Hz   1.5KW a)  Temp. range: RT+10℃ ~ 55℃ (temperature up to 50C, thickening PVC or PP material is recommended ) b) Humid. range: ≥93%R.H c) Controller time shown: 9.9s~9990hrs d) Timer: 0~9999hrs. e) Testing method: Neutral salt spray test (NSS test), acetic acid salt spray test (AASS test), salt spray test (SS test), copper accelerated acetic acid salt spray test method for salt spray test (CASS test) and so on; (For CASS test, we recommend the PP material chamber with high temperature resistance) f) Specimen holder: It can meet the tilt test at 15 ℃ ~ 30 ℃ (two layers); g) Air compressor: V-0.013/12.5(Customer provided); discharge pressure:1.25M; flow amount: 0.13m3/min   1. MMMaterial of machine body a) Salt spray chamber adopts the quality PVC reinforced hard plastic plate, the surface is smooth and anti-aging, anti-corrosion; b) Without any FRP material produced on the surface because of discoloration fibrosis. Plastic structure of the chamber is better to meet strong acid salt spray test under long-term without any damage. c) Cover is imported transparent impact-resistant plate which is convenient to test specimen when test, that can cover and the box with a water seal to prevent leakage of salt spray.   2. AccAccording to CSN, JIS, ASTM standards, can be set to constant temperature control: (a) Brine spray test: NSS (neutral); · Temp. inside chamber: 35 ℃ ± 1 ℃ · Pressure air bucket: 47 ℃ ± 1 ℃ (b) Corrosion resistance test: CASS (copper acceleration), AASS (acid) · Temp. inside chamber: 50 ° C ± 1 ° C · Pressure air bucket: 63 ℃ ± 1 ℃   3. Watwatering system. It adopts the auto watering system, supply water when lack of water. 4. HeaHeating system Test temperature inside the cabinets is heated humidification water jacket, the heater adopts advanced titanium protective tube, built-in nickel-chromium alloy infrared heater core. Heating up fast, uniform temperature distribution; and saves about one half of the power compared to FRP tank jacketed heating. 5. ExeExecutive standard GB/T 2423.17 Basic test procedures for electric and electronic products Ka"- salt spray test methods; GB/T 10125 Corrosion tests in artificial atmospheres – salt spray tests; ASTM B368 Test Method for Copper-Accelerated Acetic Acid-Salt Spray (Fog) Testing (CASS Test); JIS Z2371-2000 Methods of salt spray testing etc. ISO 9227 Corrosion tests in artificial atmospheres (Note: 2 collection device is required, bigger models than ZH-SH-90 (270L) is required; In some versions, it specifies over 400liters is necessary)  ASTM B117-18 Standard Practice for Operating Salt Spray (Fog) Apparatus (Note: 2 collection device is required, bigger models than ZH-SH-90 is required )  
Headspace Gas Analyzer Headspace Gas Analyzer-GB-DK
Product Introduction The headspace gas analyzer adopts the destructive puncture detection method and is equipped with high-precision oxygen sensors and carbon dioxide sensors to accurately detect the O2 and CO2 content of hollow packaging containers such as packaging bags, bottles, cans, etc. The analysis of the content of the headspace gas in the packaging can make a reasonable judgment on the product quality, the validity of the shelf life prediction, and the rationality of the packaging design. At the same time, it can also be used as a means of packaging tightness testing. It is a better choice for modified atmosphere preservation (MAP, CAP) packaging, large infusion bottles (bags), residual oxygen in the headspace of prefilled needles, residual oxygen detection in vials, and the results of residual oxygen detection for various food and medicines. Nowadays, the headspace gas analyzer has become an important method to check the quality of packaging design and one of the important methods to verify the product shelf life. Our headspace gas analyzer GB-DK can quickly detect O2 in production lines, warehouses, laboratories and other occasions. And CO2 content to guide production.   Test principle The gas in the sample is drawn into the sensor by a vacuum pump. The sensor outputs the current and voltage signals of the O2 and CO2 (optional) concentration in the gas in the sample in real time. The instrument calculates the content of O2 and CO2 in the gas by obtaining the current and voltage signals output by the sensor. After reaching the end conditions of the experiment, the test stops, and the instrument records the concentration of O2 and CO2 in the measured gas in the sample.   Technical parameter Item Parameter Gas to be Measured O2 (standard configuration) CO2 (optional) Measurement Principle Fluorescence optics infrared absorption Measurement Range 0%~25% (for O2) 0%~100% (for CO2) Measurement Accuracy ±0.2% ±2% Sample Size ≥5 mL (at standard atmospheric pressure) (for O2) ≥20 mL (at standard atmospheric pressure) (for CO2) Dimensions 350 mm (L)×330 mm(W)×200 mm(H) Power Supply 220 VAC±10 % 50Hz/120 VAC±10 % 60 Hz Net Weight 5kg    Features 1.Using high-precision sensors, high accuracy, good stability, long-term operation, long service life. Over-range automatic protection function to avoid damage to important sensors when the instrument fails. 2.The needle/probe safety holster is used to ensure safe testing and fast sampling. 3.Oxygen and carbon dioxide can be detected at the same time, and carbon dioxide gas can be selected for analysis according to different user needs. The sampling volume is at least 3 ml. 4.Built-in operating system, the system is equipped with an ARM control system to control the host through a touch screen (testing equipment and control software are combined into one); at the same time, the system can be expanded, such as connecting to the laboratory LIMS system. 5.The software is designed according to the requirements of the computerized system in the new version of the GMP appendix, and users are divided into multiple levels such as operators and administrators (such as administrators, operators, observers, etc. but not limited to these levels). 6.It has the audit trail function, which can realize the audit trail of the system, project operation, and method to ensure the safety and integrity of the test data. 7.Personalize the test report, set the report module that needs to be displayed, and output the report in PDF mode. The micro printer can print test reports in real time.  
Moisture vapor transmission rate WVTR MVTR Water Vapor Permeability Analyzer Cup Method W301
One test chamber water vapor permeability analyzer using weight reduction method is to test the water vapor transmission rate (WVTR) of films or sheets materials.
OTR Tester EVOH Barrier film oxygen transmission rate testing
Oxygen transmission rate (OTR) is the measurement of the amount of oxygen gas that passes through a substance over a given period. It is mostly carried out on non-porous materials, where the mode of transport is diffusion, but there are a growing number of applications where the transmission rate also depends on flow through apertures of some description.
Intelligent Compost Degradation Tester Plastics Compost Biodegradation Respirometer
GBDA-120 Compost Degradation Tester is designed in full compliance with standards such as ISO14855-1 and ASTM D5338. The mass of carbon dioxide released during biodegradation can be detected automatically, and the biodegradation percentage of degradable materials can be determined.  
Professional SGW-810 Light Transmittance and Haze Tester Haze ASTM D1003 supplier SGW-810 Light Transmittance and Haze Tester Haze ASTM D1003
Application Use for test the light transmittance and haze degree of all transparent and semi-transparent parallel plane samples (plastic plate, sheets etc), and turbidity or clarity of liquid samples (water, drinks etc), used in the industries of plastics, membrane, coatings and paints, printing ink, research institute and so on.
  • Facebook
  • Linkedin
  • Youtube
  • Twitter

Copyright @ 2025 Guangzhou Biaoji Packaging Equipment Co.,Ltd. All Rights Reserved.

Chat now

Inquiry Now

Home

Products

News

contact