packaging testing equipment Water Vapor Permeation Tester
Products
Home /

Environmental Test Equipment

/

Biodegradability Testing

/AUTO GBDA-180 Compost Degradation plastics test equipment

AUTO GBDA-180 Compost Degradation plastics test equipment

AUTO GBDA-180 The Compost Degradation Tester is based on the gravimetric method for measuring carbon dioxide emissions. It is a professional use of small reactors to determine the final biodegradability of test materials. It is suitable for the biodegradability analysis of degradable plastics and bio-based materials such as lunch box garbage, waste ground film, plastics containing plasticizers and pigment additives, etc.


  • Item NO.:

    AUTO GBDA-180
Inquiry now
Product Detail


Executive Standard

ISO14855-1ASTM D5338ASTM D6400JIS K 6953 GB22047ISO 17556-2012, GB/T19277.1


Testing Principle

The test material of this method is a mixture of inoculum of decomposed compost and inert materials (such as sea sand and vermiculite). By controlling the humidity, oxygen permeability and temperature of the compost container, the sample to be analyzed in the reaction chamber is under the action of microorganisms. The biodegradation reaction is carried out through respiration, and oxygen becomes carbon dioxide and is discharged through respiration. The amount of carbon dioxide released is measured by weighing the absorption device equipped with soda lime and sodium talc, and the decomposition rate is calculated by regular measurement. 



Technical parameter

Item

Technical Parameter

Temperature Control Range

Room Temperature 80°C

Temperature Control Accuracy

±0.5°C

Flow Control Range

0.01~1L/min

Flow Control Rate Accuracy

±1.0%FS

Flow Detection Range

0.012L/min

Flow Detection Accuracy

±1.0%FS

Carbon Dioxide Detection Range

010000ppm

Carbon Dioxide Detection Accuracy

0-3000 ppm, ±40 ppm. 3000-10000 ppm, ±2%

Oxygen Detection Range

025%

Oxygen Detection Accuracy

±1%FS

Test Chambers

18 chambers

Air Source Connection

φ8

Air Source Pressure

0.20.8 MPa

Test Cavity Volume

3.5L

Dimensions

3600mm*810mm*1930mm

Weight

1100kg

Power

3000W

Power Supply

AC 220V, 50Hz




Features

Precise control of experimental conditions

  • 360℃ air bath temperature control, intelligent PID module algorithm can accurately control the temperature required for the reaction.
  • Intelligent detection of humidity, automatic humidification of the external water tank and condensate return technology to ensure that the standard requirements for the water content of the inoculum are met within the test cycle.


Technological advancement
  • Intelligent air tightness monitoring, equipped with high-precision brand flowmeters, real-time monitoring system sealing performance, providing suspected leakage alarm function, ensuring that each composting container can maintain sufficient aeration conditions during the test.
  • Support accidental power failure during the test period, and the test function will continue to be restored after incoming calls.
  • The channels can be freely combined, and the blank, reference, and sample modes can be freely set for independent testing.
  • Real-time display of carbon dioxide quality curve and biodegradation rate curve.
  • Support remote monitoring of the experimental process through mobile phones, ipads, and PCs.


Result validity analysis

  • The software contains a result validity judgment module, which can display the biodegradation rate of the reference material after 45 days, the carbon dioxide (mg) produced by the blank container within 10 days before the experiment (mg)/the volatile solids of the inoculum (g), and the biodegradation rate of 18 channels Relative deviation.
  • The report template contains parameters such as the average carbon dioxide value of the blank group, theoretical carbon dioxide, generated carbon dioxide, biological decomposition rate, relative decomposition rate and time.


Personalized customization

  • The tail gas analysis module can be customized to meet different scientific research needs, such as methane, ammonia, nitrogen dioxide, hydrogen sulfide, sulfur dioxide, odor, VOC and other gas characteristic parameters.
  • Support 12/18/24/30 station customization, support data mean mode customization.





Send A Message

Leave us a message, we will get back to you ASAP.

Related Products
Intelligent Compost Degradation Tester Plastics Compost Biodegradation Respirometer
GBDA-120 Compost Degradation Tester is designed in full compliance with standards such as ISO14855-1 and ASTM D5338. The mass of carbon dioxide released during biodegradation can be detected automatically, and the biodegradation percentage of degradable materials can be determined.  
water vapor permeability WVTR MVTR Water Vapor Transmission Rate Testing Instrument Infrared Method for Plastic Film and Sheeting-W413
Moisture vapor permeability analyzer using infrared method is to test the water vapor transmission rate (WVTR) of films or sheets materials for food and pharmaceutical industries.
Atmosphere Refrigerator AUTO GQ900 Modified Atmosphere Refrigerator
AUTO GQ-900 Modified Atmosphere Refrigerator is mainly for a variety of fruits, vegetables, flowers, seedlings, etc. on the market for storage and preservation tests, through microelectronics technology to automatically control the concentration of oxygen, nitrogen, carbon dioxide, ethylene in the box, as well as control temperature, humidity conditions to achieve the preservation effect, is a microorganism, environmental protection, food production, universities, scientific research institutions and other units indispensable ideal equipment.
Exhalation Valve Air Tightness Tester Medical Mask Exhalation Valve Air Tightness Tester - GB-HQ1000
Medical Mask Exhalation Valve Air Tightness Tester  is Used to detect the air tightness of the mask breath valve. GBPI offers mask testing machines for surgical face masks, N95 masks, Melt-blown fabric. BFE Tester, PFE Tester, N95 Tester, Melt-blown fabric Tester      
Composite Film Heat Seal Tester Composite Film Heat Sealing Analyzer With ASTM F2029 Testing Standard GBB-A
GBB-A Heat Seal Tester accurately test the heat seal temperature range, heat seal strength, suitable heat seal speed and heat seal pressure of plastic film, flexible packaging composite film, coated paper, aluminum foil, etc. It is applied to the quality control of various plastic film, food and drug manufacturer, the scientific research and teaching experiment of testing institutions and schools
Lab  Teser Use for fabric China meltblown tester ppe testing equipment for fabric viral filtration efficiency tester
It is used to test the percentage of materials containing bacteria suspended particles at the specified flow rate. The dual gas path simultaneous comparison sampling method is used to improve the accuracy of sampling, which is suitable for the performance testing of bacterial filtration efficiency of medical surgical masks by metrological inspection departments, scientific research institutes, medical mask manufacturers and other relevant departments.
Vacuum Decay Leak Detection Tester Dual Pressure Methods Vacuum Decay Leak Detection Tester AUTO GBM-L2
Introduction AUTO GBM-L2 Dual-Pressure Methods Vacuum Decay Leak Detection Tester adopts the test principle of vacuum decay method/pressure decay to detect micro-leakage of finished packaging. It can be applied to packaging systems composed of vials, ampoules, Leakage detection of pre-filled needles, eye drop bottles, HDPE bottles, infusion bottles/bags and other pharmaceutical packaging, food packaging, and chemical industry packaging.   Test principle The host is connected to a sealed test chamber customized according to the sample. When performing the vacuum decay method test, the instrument evacuates the test chamber, and a pressure difference is formed inside and outside the sample. Under the action of the pressure, the gas/liquid in the sample enters the test chamber through the leak hole. The main engine uses the absolute pressure sensor and the differential pressure sensor to monitor the pressure change in the chamber to judge whether the sample leaks. When performing the pressure decay method test, the instrument fills the test chamber with a predetermined air pressure, and the gas in the test chamber enters the sample through the leak hole. The host uses absolute pressure sensors and differential pressure sensors to monitor the pressure changes in the chamber to determine whether the sample is leaking.   Standard ASTM F2338-2009(2013),  YY-T 0681.18-2020,  USP<1207.2>, ASTM F2095   Specification Item Parameters Absolute Pressure Testing Range (0 - 300) kPa Differential Pressure Testing Range (-2 - 2) kPa Detection Sensitivity 1 - 3 μm Balancing/Testing Time 1 - 3600 s Vacuum Purge Time 1 - 3600 s Set Flow Rate 0 - 3 mL/min Testing System Dual Sensor Technology/Dual Cycle Testing Testing Chamber Customized according to the sample Applicable Products Vials, Ampoules, Prefilled Syringes, Infusion Bottles/Bags, etc. Detection Principle Vacuum Decay Method/Pressure Decay Method Dimensions of the Main Unit 495 mm455 mm280 mm Ambient Temperature 20℃ - 25℃ Relative Humidity 40% - 60% Working Power Supply AC 220V, 50HZ   Features u Dual-Pressure Methods, to help solve testing difficulties The double combination of vacuum decay method and pressure decay method solves the problem of easy misjudgment and false negative for freeze-dried powder injections containing vacuum in the bottle using a single vacuum decay method. Based on dual-sensor and dual-circulation system technology, high-quality absolute pressure sensor and differential pressure sensor, with an accuracy of 0.1% FS, can effectively detect large and small leaks, accurately calculate the leak hole diameter, and give a pass or fail judgment.   The instrument has low sensitivity and good test repeatability For rigid samples, the detection sensitivity is as low as 1 μm, and the test repeatability is as low as 0.8%. The instrument has stable performance, low noise and good repeatability. u Imported brand accessories, excellent performance Imported brand vacuum pump, pumping rate up to 3 L/s, noise as low as 50 DB, high ultimate vacuum, convenient oil level detection and replacement. The imported gas mass flow controller can simulate micro-leaks arbitrarily, with a resolution of 0.001 mL/min, which provides a reliable guarantee for the method verification of instrument sensitivity. u Large size touch screen, intelligent operation Color 7-inch touch screen, clear view, sensitive touch, easy to operate. Equipped with a micro-printer, USB data interface, and supports PC software measurement and control operation. The test software is designed according to the GMP appendix "Computerized System". It has an audit trail function and multi-level authority settings for users, which can meet the needs of the pharmaceutical industry for data traceability. u Personalized customization to meet the needs of different samples For different test samples, it supports customization of suitable test chambers to meet the needs of different tests. For the same type of samples, it supports customized nesting mode, which can realize the sharing of a test chamber for samples of various specifications.   Application       Freeze-dried powder injection Injection Prefill needle       Eye drops Plastic Ampoule BFS Infusion bags   Factory configuration Standard Host machine, vacuum pump, test chamber and 3 sets of yin and yang control (customized as required), 11-inch touch panel, professional software (GMP) Optional Imported gas flow meters, air compressors, printers, calibration certificates  
Moisture permeation rate tester Water Vapor Permeability Analyzer For LDPE Film Gravimetric Method - W533
A533 water vapor permeability analyzer is to test the water vapor transmission rate (WVTR) of films or sheets materials.
water vapor transimission rate WVTR MVTR water vapor permeability analyzer electrolytic sensor method for flexible barrier sheet materials test - W201
Water vapor permeability analyzer is used to test water vapor transmission rate (WVTR) of films or sheets materials for flexible packaging.
Xenon arc lamp aging test chamber Xenon arc lamp aging test chamber GB-OXD-15P
  1.Profile Xenon lamp aging test chamber simulates the full spectrum lamp with Xenon arc lamp to reappear the destructive wave. It serves for the environmental simulation and accelerated test for research and development, product development and quality control. Besides, the chamber also applies to the choice of new material, weathering test after composition of material and improvement for the current material. It simulate different environment, and show the material changes under the explosion of sunlight.   The chamber meets the standard: GB/T16585-1996 , GB14522-93 , GB/T16422.3-97, ASTM D2565 and so on. The Chamber is to determine the color fastness, aging resistance of textiles, plastics, coatings, rubber products or other materials by objecting to the simulated conditions of nature weather (sun, rain, temperature and humidity, etc.).     Technical parameters   2.Material of construction u Full spectrum lamp u Optional filter system u Water spraying function u Humidity control u Temp. control system in the chamber u Sample fixed hold of irregular shape u USA imported xenon arc lamp u Easy installation and operation, seldom daily maintainance. u Service life time deepens on the irradiance level, usually 1600hrs. It’s easy to replace the lamp, with filter of long service life time to ensure the necessary spectrum. 3.Technical parameters Model No., equipment name GB-OXD-15P Xenon aging test chamber Interior sizes   W500×D500×H600mm  Exterior sizes W1050×D1050×H1750mm (or so) Temperature range 0℃~80℃ Controller imported programmable 7inch touch screen Machine components material inner and outer 304# stainless steel Sample holder Aluminum alloy frame base Protection device residual-current circuit breaker (RCCB) to control the warning for loop overload, thermal protection and water shortage protection. Temp. deflection ±2℃  (without lighting) Humidity range 30%~98%R.H Humid. deflection ±2.5%R.H(Humid.≥75%R.H); ±3%R.H(Humid.≤75%R.H) without lighting Light source imported full spectrum xenon arc lamp(average useful life 1600hrs) Raining time 1~9999min (adjustable) Raining period 1~240min, interval(cut)adjustable lamp power Test period for Temp., irradiation, condensation, spray can be adjustable Lamp 1.8KW Wave length range 290-800nm heating power (or so) 4.0KW humidification (or so) 2.0KW Light irradiance 1200w/m2 Distance between arc center and sample holder: 350~380mm Revolving speed of sample holder ≥1r/min  water spray period a. spray time: 0~99h59min (Continuing or adjustable) b. stop time: 0~99h59min, (Continuing or adjustable)   lighting time Continuing programming control available black panel temp. 85±3℃ cooling method Mechanical wind cooling; Room temp. less than 26℃ is recommend, relative humid: ≤85%R.H; humid. and temp. tested after 2 hours under idle condition. 4.Temperature & humidity running control system controller imported programmable 7inch touch screen precision range set precision: temp. ±0.1℃, humid: ±2%R.H, indicated precision: temp.±0.1℃,humid.: ±1%R.H temp. & humid. sensor Platinum Resistance(PT100Ω/MV) black panel temp. double-metal black panel temp. thermometer water-supplying system auto-control humidication water-supplying, Xenon arc lamp with cycling cooling water circulation system low noise heat-resistance conditioning motor, multi-blade centrifugal wind wheel control system mainly consists of operation panel, central controller, kinds of key-pressing sw., status indicating lamp, excution electric device etc.. 5.Structure section of machine body The chamber consists of several section: chamber body, control system, refrigeration system, heating system, humidation system, wind system, raining system, lighting system and so on. Chamber body a. With integrated structure, the chamber consists of up left part as working room, up right part as electric controller which is convenient to control, down part as compressor cooling group, sample holder rotation device, Xenon lamp condensation water box, water pump and other executive devices. b. Inner wall of chamber adopts international SUS304# material. c. Temp. insulation material is polyurethane foam and ultra-fine fibre glass, with good temp. insulation result, no frost and condensation on the external surface of chamber. d. condensate water outfall set at the bottom of chamber e. Environmental heat-resistance silicon sealing tape as the material of door frame. f. Viewing window with eye-protective film on its surface to protect eyes from being injured by Xenon lamp. external chamber body a. Seal of door adopts the double-layer of refined silicone rubber with reliable sealing effect and no aging or hardening phenomenon under high or low temperature. b. Single door (embedded handle); c. Viewing window, antifrost device and lamp equipped on the door viewing window Size:25 cm W × 30 cm H;equipped with Anti-radiation hollow glass 6.Electric control section of chamber a. As the core part of chamber b. Air pressure switch as the main switch to control the main circuit; c. Safety measures for electric section: it warns and cut electricity automatically after tested the action from following protection devices: a) overheat protection in working room b) lockage of phase, leakage protection c) overcurrent protection of motor d) overpressure/overload protection of cooling machine e) short out/overload protection of heater, humidifer f) fusing protection of fuse 7.Working section of chamber Condensation section of compressor. a.Cooling system: as the core part of cooling system, we adopt one set of compressor of Tecumseh from France in this case to ensure the cooling requirement in the working room. b.For adjustment technology and design of cooling system, we take an efficiency processing way to ensure the adjustment for the cooling amount and consumption of cooling system under the normal running, to make the failure rate down to the economical statue. c.Cooling evaporator: it locates in interlayer at one side of chamber which ventilate by force from blast motor to exchange heat fast. d.Cooling method of cooling system: forced air cooling Cooling refrigerant:Environmental R404a; Heating system a. Heating method: heating directly in the chamber; b. Military level stainless steel heating tube used, with fast and stable heating to keep temperature in the working room from rapid change. It with corrosion resistance, anti-high-low temperature, no leakage and other advantages. c. With SSR (solid relay)output control, without noise, reliable working, long service life time, fast switching, low interference from outside, and easy operation etc.. Rain system.   it consists of nozzle, solenoid valve, water-supplying and connecting pipe. Lighting system. It consists of xenon lamp, lamp cover, lamp contactor and other controlling parts. Energy compensation is got by adjusting samples distance, pressure and current. Wind system  It locates in the interlayer at the back of chamber, there are heater, fan blade, evaporator, PT100 temperature samples sensor etc.. when wind machine running, the air is intaken to the channel from working room, and blow out from the bottom after cooled; the air exchanged in the working room with samples is intaken again to the channel and mix; after several circulation, it will reach the purposed temperature, and ensure the high index of temp. and humid in the chamber at the same time. Cooling dehumidification system take the compressor of world brand Tecumseh from France to keep constant temperature, decrease the humidity in the working room and cool the xenon lamp. Humidification Steam generator: to generate steam from water Water level control: control the water inlet by solenoid valve, and water level by liquid level switch to provide the signal for water-supply and warning. Air circulation section Cycling channel and winding machine inside the chamber, it uses the high efficiency cooling machine and energy adjusting system, efficiency heat exchange to reach the aim of temperature change, which also improves the airflow and heat exchange between airflow, heating and humidification, as a result, it improves the humidity uniformity in the working room. 8. Enclosured files: operation manual, warranty card 9. Machine running requirements Temp. 5℃~+32℃ Humidity ≤85% Power supply AC220(±10%)V/50HZ    10. Core components parts Remark: replacement of some small parts of the same quality is possible because of material shortage.    
Optical Properties Testing P60 Standard Light Source Optical Properties Testing
P60 Standard Light Source Used for color observation, color contrast and color matching in a wide range of industries of printing, paints, printing ink, plastics, dyeing and so on.
aluminum film Vacuum Coating Thickness Tester Vacuum Coating Thickness Tester For Vacuum Aluminum Film GH-E
Vacuum Coating Thickness Tester is applied to various vacuum aluminum film, aluminized paper, and other conductive coating materials to test the resistance value, evenness, thickness and so on.
  • Facebook
  • Linkedin
  • Youtube
  • Twitter

Copyright @ 2025 Guangzhou Biaoji Packaging Equipment Co.,Ltd. All Rights Reserved.

Chat now

Inquiry Now

Home

Products

News

contact