• Facebook
  • Linkedin
  • Youtube
  • Twitter
packaging testing equipment Water Vapor Permeation Tester
Products
Home /

Environmental Test Equipment

/

Aging Test Chamber

/Xenon arc lamp aging test chamber GB-OXD-15P

Xenon arc lamp aging test chamber GB-OXD-15P

Inquiry now
Product Detail


1.Profile

Xenon lamp aging test chamber simulates the full spectrum lamp with Xenon arc lamp to reappear the destructive wave. It serves for the environmental simulation and accelerated test for research and development, product development and quality control. Besides, the chamber also applies to the choice of new material, weathering test after composition of material and improvement for the current material. It simulate different environment, and show the material changes under the explosion of sunlight.

 

The chamber meets the standard: GB/T16585-1996 , GB14522-93 , GB/T16422.3-97, ASTM D2565 and so on.

The Chamber is to determine the color fastness, aging resistance of textiles, plastics, coatings, rubber products or other materials by objecting to the simulated conditions of nature weather (sun, rain, temperature and humidity, etc.).



Technical parameters


2.Material of construction

Full spectrum lamp

Optional filter system

Water spraying function

Humidity control

Temp. control system in the chamber

Sample fixed hold of irregular shape

USA imported xenon arc lamp

Easy installation and operation, seldom daily maintainance.

Service life time deepens on the irradiance level, usually 1600hrs. It’s easy to replace the lamp, with

filter of long service life time to ensure the necessary spectrum.

3.Technical parameters

Model No., equipment name

GB-OXD-15P Xenon aging test chamber

Interior sizes  

W500×D500×H600mm 

Exterior sizes

W1050×D1050×H1750mm (or so)

Temperature range

080

Controller

imported programmable 7inch touch screen

Machine components material

inner and outer 304# stainless steel

Sample holder

Aluminum alloy frame base

Protection device

residual-current circuit breaker (RCCB) to control the warning for loop overload, thermal protection and water shortage protection.

Temp. deflection

±2  (without lighting)

Humidity range

3098R.H

Humid. deflection

±2.5%R.H(Humid.≥75%R.H); ±3%R.H(Humid.≤75%R.H) without lighting

Light source

imported full spectrum xenon arc lamp(average useful life 1600hrs)

Raining time

19999min (adjustable)

Raining period

1240min, intervalcutadjustable

lamp power

Test period for Temp., irradiation, condensation, spray can be adjustable

Lamp

1.8KW

Wave length range

290-800nm

heating power (or so)

4.0KW

humidification (or so)

2.0KW

Light irradiance

1200w/m2

Distance between arc center and sample holder:

350380mm

Revolving speed of sample holder

≥1r/min

water spray period

a. spray time: 099h59min (Continuing or adjustable)

b. stop time: 099h59min, (Continuing or adjustable)  

lighting time

Continuing programming control available

black panel temp.

85±3

cooling method

Mechanical wind cooling; Room temp. less than 26 is recommend, relative humid: ≤85%R.H; humid. and temp. tested after 2 hours under idle condition.

4.Temperature & humidity running control system

controller

imported programmable 7inch touch screen

precision range

set precision: temp. ±0.1, humid: ±2R.H, indicated precision: temp.±0.1,humid.: ±1R.H

temp. & humid. sensor

Platinum Resistance(PT100Ω/MV)

black panel temp.

double-metal black panel temp. thermometer

water-supplying system

auto-control humidication water-supplying, Xenon arc lamp with cycling cooling water

circulation system

low noise heat-resistance conditioning motor, multi-blade centrifugal wind wheel

control system

mainly consists of operation panel, central controller, kinds of key-pressing sw., status indicating lamp, excution electric device etc..

5.Structure section of machine body

The chamber consists of several section: chamber body, control system, refrigeration system, heating system, humidation system, wind system, raining system, lighting system and so on.

Chamber body

a. With integrated structure, the chamber consists of up left part as working room, up right part as electric controller which is convenient to control, down part as compressor cooling group, sample holder rotation device, Xenon lamp condensation water box, water pump and other executive devices.

b. Inner wall of chamber adopts international SUS304# material.

c. Temp. insulation material is polyurethane foam and ultra-fine fibre glass, with good temp. insulation result, no frost and condensation on the external surface of chamber.

d. condensate water outfall set at the bottom of chamber

e. Environmental heat-resistance silicon sealing tape as the material of door frame.

f. Viewing window with eye-protective film on its surface to protect eyes from being injured by Xenon lamp.

external chamber body

a. Seal of door adopts the double-layer of refined silicone rubber with reliable sealing effect and no aging or hardening phenomenon under high or low temperature.

b. Single door (embedded handle);

c. Viewing window, antifrost device and lamp equipped on the door

viewing window

Size25 cm W × 30 cm Hequipped with Anti-radiation hollow glass

6.Electric control section of chamber

a. As the core part of chamber

b. Air pressure switch as the main switch to control the main circuit;

c. Safety measures for electric section: it warns and cut electricity automatically after tested the action from following protection devices:

a) overheat protection in working room

b) lockage of phase, leakage protection

c) overcurrent protection of motor

d) overpressure/overload protection of cooling machine

e) short out/overload protection of heater, humidifer

f) fusing protection of fuse

7.Working section of chamber

Condensation section of compressor.

a.Cooling system: as the core part of cooling system, we adopt one set of compressor of Tecumseh from France in this case to ensure the cooling requirement in the working room.

b.For adjustment technology and design of cooling system, we take an efficiency processing way to ensure the adjustment for the cooling amount and consumption of cooling system under the normal running, to make the failure rate down to the economical statue.

c.Cooling evaporator: it locates in interlayer at one side of chamber which ventilate by force from blast motor to exchange heat fast.

d.Cooling method of cooling system: forced air cooling Cooling refrigerantEnvironmental R404a

Heating system

a. Heating method: heating directly in the chamber;

b. Military level stainless steel heating tube used, with fast and stable heating to keep temperature in the working room from rapid change. It with corrosion resistance, anti-high-low temperature, no leakage and other advantages.

c. With SSR (solid relay)output control, without noise, reliable working, long service life time, fast switching, low interference from outside, and easy operation etc..

Rain system.

 

it consists of nozzle, solenoid valve, water-supplying and connecting pipe.

Lighting system.

It consists of xenon lamp, lamp cover, lamp contactor and other controlling parts. Energy compensation is got by adjusting samples distance, pressure and current.

Wind system 

It locates in the interlayer at the back of chamber, there are heater, fan blade, evaporator, PT100 temperature samples sensor etc.. when wind machine running, the air is intaken to the channel from working room, and blow out from the bottom after cooled; the air exchanged in the working room with samples is intaken again to the channel and mix; after several circulation, it will reach the purposed temperature, and ensure the high index of temp. and humid in the chamber at the same time.

Cooling dehumidification system

take the compressor of world brand Tecumseh from France to keep constant temperature, decrease the humidity in the working room and cool the xenon lamp.

Humidification

Steam generator: to generate steam from water

Water level control: control the water inlet by solenoid valve, and water level by liquid level switch to provide the signal for water-supply and warning.

Air circulation section

Cycling channel and winding machine inside the chamber, it uses the high efficiency cooling machine and energy adjusting system, efficiency heat exchange to reach the aim of temperature change, which also improves the airflow and heat exchange between airflow, heating and humidification, as a result, it improves the humidity uniformity in the working room.

8. Enclosured files: operation manual, warranty card

9. Machine running requirements

Temp.

5~+32

Humidity

≤85%

Power supply

AC220±10%V/50HZ   

10. Core components parts

Remark: replacement of some small parts of the same quality is possible because of material shortage.


Send A Message

Leave us a message, we will get back to you ASAP.

Related Products
Professional Ozone Aging Test Chamber (Dynamic Stretching) GB-OCY-150M supplier Ozone Aging Test Chamber (Dynamic Stretching) GB-OCY-150M
1 Function Ozone in the atmosphere is very little, while it’s a major factor in rubber cracking, the product simulate and enhance atmospheric ozone condition to study the role of ozone on the rubber, and to rapid identificate and evaluate rubber resistance for ozone aging and anti-ozone agent protection. According to“GB / T7762-2003 Test Method for Static Tensile Test of Ozone Resistance Cured Rubber or Thermoplastic Rubber”,“GB / T2951.21-2008 General Test Method for Insulation and Sheathing Material of Cable”,“GB / T 11206-2009 Rubber Aging test surface cracking method”, and other relevant standards of the test method. 2.1 Structure  All-in-one machine 2.2 Material a) Inner chamber: SUS304 stainless steel plate b) External chamber: SUS304 stainless steel plate or baking finish. Insulation: rigid polyurethane foam + aluminum insulation cotton with double protection. 2.3 Machine door a) Single door, open from left. b) Window frame / door frame with two silicone rubber seal and anti-condensation heating device. c)With observation window (W220xH250mm), lights above the window and door.  2.4 Requirements for sample holder (for dynamic-type only)   a)At both ends of the sample to be fixed with a clamp under the required elongation, the longitudinal direction of the specimen shall be substantially parallel to the direction of air flow when in contact with ozonized air. b) Clamps shall be made of a material (eg aluminum) which does not readily decompose ozone. c) Allow the sample to rotate at a speed between (20 ^ -25) mm / s, in a plane perpendicular to the dry gas flow, with each sample moving continuously along the same path. d) The time of one revolution of the same specimen is (8 ^ -12) min. The scanning area of the specimen shall be at least 40% of the effective area of the test chamber. Specimen preparation shall conform to the provisions of GB / T 9865.1. The test specimen is preferably cut from the new test piece and, if desired, may be cut from the finished product. At least 3 specimens shall be required for per test condition. The standard length of the specimen is not less than 10mm, and thickness not less than 0.2mm. The length of specimen between the two ends of the clamp before drawing is not less than 40mm. 3 Control panel a) Controller display b) Power switch c) Fault alarm d)Wavelength switch e)light switch button 4 Enclosure configuration a) With a stainless steel SUS # 304 shelf turntable b) One φ50mm lead hole:, and with a hole cover and silicone rubber plug. c) Move casters 4 pcs d) Horizontal mounting brackets 4 pcs e) There is a drainage hole in the back of the machine to facilitate the drainage of condensate; (8mm in diameter) Three-phase five-wire cable (four-core cable + protective grounding wire) 1 pc, (three meters long).
Professional PCT Test Chamber / Pressure Cooker test chamber GB-OPCT-30 supplier PCT Test Chamber / Pressure Cooker test chamber GB-OPCT-30
1.Function It’s widely used in rubber products, magnetic materials, circuit boards, muti-layer circuit boards, IC, LCD, electronics and other products sealing performance testing. 2.Characteristics 1) The imported double-temperature structure with high temperature resistant solenoid valve is used to minimize the failure rate. 2) Independent steam generation chamber to avoid direct impact of steam on the product, so as not to cause partial damage to the product. 3) The door lock labor-saving structure solves the shortcomings of the locking difficulty of the first-generation product disc handle. 4) Cool air before the test; the design of the exhaust air in the test (air discharge in the test barrel) improves the pressure stability and reproduction. 5) Ultra long-term experimental running time up to 400 hours. 6) Water level protection, through the test room water level Sensor to detect protection. 7) Tank with anti-pressure design, the box body with pressure (150 ° C) up to 2.65kg, in line with the water pressure test of 6kg. 8) Two-stage pressure safety protection device, adopting two-stage combined controller and mechanical pressure protection device. 9) Safety protection pressure button, two-stage automatic pressure button for emergency safety device. 10) Bias test terminal withstand voltage up to 3000V (optional) 11) USB for exporting the history data, curve. 3.Technical parameters 1)Temperature range: +100°C~+132°C (Saturated vapor temperature) 2)Humidity Range: 100% steam Humidity 3)Humidity Control Stability: ±1%RH 4)Working pressure: 1.2~2.89kg/cm2 (including 1atm) 5)Time Range: 0 Hr to 999 Hr 6)Pressurization time: 0.00 Kg ~ 1.04 Kg/cm2 about 45 minutes 4.Material of chamber 1)Test chamber size:∮300 mm x L500 mm; 2)Overall size: W900x D900 x H1400 mm; 3)Inner barrel material: Stainless steel plate material (SUS# 316, 3mm); 4)Outer barrel material: stainless steel plate material or spray plastic; 5)Insulation material: rock wool and hard polyurethane foam insulation 6)Steam chamber heating tube: Titanium tube is heated and never rusts. 7)Control System: Taiwan-made Delta color touch PLC to control humidity and steam temperature (using PT-100 Platinum temperature sensor). (Imported large-screen touch controller) 5.Mechanical structure 1)Round inner box, stainless steel round test inner box structure, in line with industrial safety container standards, can prevent dew condensation design during test. 2)Round lining, stainless steel circular lining design, can avoid direct impact of vapor latent heat on the sample. 3)Precision design, good air tightness, low water consumption, and can be operated continuously for 400Hrs every time. 4)The patented packing design makes the door and the box more tightly combined, which is completely different from the traditional extrusion type, and can extend the packing life. 5)Critical point LIMIT mode automatic safety protection, abnormal cause and fault indicator display. 6)Security Protection: a)Imported high temperature sealed solenoid valve adopts double circuit structure to ensure no leakage of pressure. b)The whole machine is equipped with over-pressure protection, over-temperature protection, one-button pressure relief, manual pressure relief and multiple safety guarantee devices to ensure users to the greatest extent. c)Use and safety. d)Back pressure door lock device, the test box door cannot be opened when there is pressure inside the test chamber. 6.Other accessories. 1)Test rack 1 group 2)Sample tray   7.Ambient environment & Facilities. 1)It can be allowed to use the working environment temperature 5 ° C ~ 30 ° C; experimental water: pure water or distilled water 2)System power fluctuations should not be greater than ± 10, 220V 20A.
Professional Temperature & Humidity Test Chamber OTH-150DJ supplier Temperature & Humidity Test Chamber OTH-150DJ
OTH-150DJ is used to test the performance of materials in various environments and test the heat resistance, cold resistance, dry resistance and humidity resistance of various materials. It is suitable for quality testing of products such as electronics, electrical appliances, mobile phones, communications, instruments, vehicles, plastic products, metals, food, chemicals, building materials, medical care, and aerospace.
Professional Salt spray test chamber GB-OSH-60 supplier Salt spray test chamber GB-OSH-60
1. FunFunction Salt spray test chamber is used for the quality inspection and corrosion resistance test of a variety of materials, including metal plating, metal, electronic components, chemical coatings, paint, automobiles, motorcycles, metal ware, screws, springs, magnetic materials, organic and inorganic coating, anodizing, anti-rust oil industry etc. after the surface treatment. 1. ecGTechnical parameters 1. MODEL GB-OSH-60 2. Temperature inside chamber 35℃±1℃/ 50℃±1℃ 3. Temperature of pressure barrel 47℃±1℃/ 63℃±1℃  4. Inner size W600 x H400 x D450mm   5. External size W1080 x H1080 x D650mm 6. Temperature Uniformity ≤±2℃ 7. Uniformity Fluctuation ≤±0.5℃ 8. Salt fog settlement 1~2ml/h.80cm2 9. Compressed air pressure 1.00±0.01kgf/cm² 10. Spray mode Continuous or intermittent spray optional 11. Power supply AC  220V   50Hz   1.5KW a)  Temp. range: RT+10℃ ~ 55℃ (temperature up to 50C, thickening PVC or PP material is recommended ) b) Humid. range: ≥93%R.H c) Controller time shown: 9.9s~9990hrs d) Timer: 0~9999hrs. e) Testing method: Neutral salt spray test (NSS test), acetic acid salt spray test (AASS test), salt spray test (SS test), copper accelerated acetic acid salt spray test method for salt spray test (CASS test) and so on; (For CASS test, we recommend the PP material chamber with high temperature resistance) f) Specimen holder: It can meet the tilt test at 15 ℃ ~ 30 ℃ (two layers); g) Air compressor: V-0.013/12.5(Customer provided); discharge pressure:1.25M; flow amount: 0.13m3/min   1. MMMaterial of machine body a) Salt spray chamber adopts the quality PVC reinforced hard plastic plate, the surface is smooth and anti-aging, anti-corrosion; b) Without any FRP material produced on the surface because of discoloration fibrosis. Plastic structure of the chamber is better to meet strong acid salt spray test under long-term without any damage. c) Cover is imported transparent impact-resistant plate which is convenient to test specimen when test, that can cover and the box with a water seal to prevent leakage of salt spray.   2. AccAccording to CSN, JIS, ASTM standards, can be set to constant temperature control: (a) Brine spray test: NSS (neutral); · Temp. inside chamber: 35 ℃ ± 1 ℃ · Pressure air bucket: 47 ℃ ± 1 ℃ (b) Corrosion resistance test: CASS (copper acceleration), AASS (acid) · Temp. inside chamber: 50 ° C ± 1 ° C · Pressure air bucket: 63 ℃ ± 1 ℃   3. Watwatering system. It adopts the auto watering system, supply water when lack of water. 4. HeaHeating system Test temperature inside the cabinets is heated humidification water jacket, the heater adopts advanced titanium protective tube, built-in nickel-chromium alloy infrared heater core. Heating up fast, uniform temperature distribution; and saves about one half of the power compared to FRP tank jacketed heating. 5. ExeExecutive standard GB/T 2423.17 Basic test procedures for electric and electronic products Ka"- salt spray test methods; GB/T 10125 Corrosion tests in artificial atmospheres – salt spray tests; ASTM B368 Test Method for Copper-Accelerated Acetic Acid-Salt Spray (Fog) Testing (CASS Test); JIS Z2371-2000 Methods of salt spray testing etc. ISO 9227 Corrosion tests in artificial atmospheres (Note: 2 collection device is required, bigger models than ZH-SH-90 (270L) is required; In some versions, it specifies over 400liters is necessary)  ASTM B117-18 Standard Practice for Operating Salt Spray (Fog) Apparatus (Note: 2 collection device is required, bigger models than ZH-SH-90 is required )
UV lamp aging test chamber UV lamp aging test chamber GB-OUVA-115
Accelerated weathering tests are performed on materials by simulating ultraviolet radiation and condensation in natural sunlight to obtain results on material weathering resistance. It can simulate environmental conditions such as ultraviolet, rain, high temperature, high humidity, condensation, and darkness in natural climates. By reproducing these conditions, it can be combined into a cycle and allowed to automatically complete the cycle as required.
Box Compression Tester Box Compression Tester for corrugated box and packing box
Box Compression Tester mainly used in various types of corrugated box and packing box. It is the basic instrument for corrugated carton such as small and medium-sized packing box of the compression strength performance test. The various performance parameters and technical indicators is in line with ISO2872 The Package – Complete and Full Transport Package- Compression Test ", ISO2874 The Package – Complete and Full Transport Package-Stacking Test using pressure testing machine "
migration tester Full-automatic Total Migration Tester -AUTO ZF1800G
Full-automatic Total Migration Tester AUTO ZF1800G has an integrated system design of water bath evaporation, heating, drying, cooling, and constant temperature weighing. The testing process is fully automated without manual operation. It is suitable for testing the overrall migration (non-volatile matter, evaporation residue) and other items in the fields of purified water, pharmaceutical packaging materials, food packaging, cigarette tipping paper and chemical reagents. It can also be applied to the water content, loss on drying and other items of solid samples, and the total dissolved solid content test in water quality testing.
Compression Resistance Tester Compression Tester for Bag Packaging GBN200A
The Compression Tester GBN200A is professionally used to test the pressure resistance and burst resistance of various packaging bags. It can set the pressure and measure the deformation; set the deformation and measure the pressure resistance. It is an ideal testing equipment for quality inspection, drug inspection, scientific research, packaging, film, food, medicine, daily chemical and other industries.
Atmosphere Refrigerator AUTO GQ300 Modified Atmosphere Refrigerator
AUTO GQ-300 Modified Atmosphere Refrigerator is mainly for a variety of fruits, vegetables, flowers, seedlings, etc. on the market for storage and preservation tests, through microelectronics technology to automatically control the concentration of oxygen, nitrogen, carbon dioxide, ethylene in the box, as well as control temperature, humidity conditions to achieve the preservation effect, is a microorganism, environmental protection, food production, universities, scientific research institutions and other units indispensable ideal equipment.
Film Pendulum Impact Tester Pendulum Impact Tester-GBG-L2
Introduction Designed and manufactured according tostandards likeGB/T 8809、ASTM D3420, GBG-L2 Pendulum Impact Tester is suitable for determining pendulum impact resistance of the film materials,composite film,metallic foil and so on. The machine can be used in scientific research, teaching, industrial and mining enterprises, laboratory, research institute and quality supervision department.
Leakage Tester Plastic Bags Electronic Leakage Tester GB- M2
Electronic Leakage Tester applies to test the hermetic sealing quality and performance of packaging bags, bottles, cans and so on, used in industries of food, beverage, pharmaceuticals, personal care and so on
filling and sealing machine Automatic Rotary Pouch Spout inserting and Sealing Machine GF-1600H
This sealing/filling/capping machine(Packaging Machine/Packaging Machinery)is applicable for Fruit Juice/Salt /Sanitizing Gel/Skin Care/Sugar Powder/Tomato Sauce/ Ketchup/ Detergents Soap Packing in form of top/corner spout pouch or top/corner spout stand up pouch, 3-side sealing bags, and doypacks.
  • Facebook
  • Linkedin
  • Youtube
  • Twitter

Copyright @ 2024 Guangzhou Biaoji Packaging Equipment Co.,Ltd. All Rights Reserved.

Chat now

Inquiry Now

Home

Products

News

contact