packaging testing equipment Water Vapor Permeation Tester
Products
Home /

Barrier And Permeation Properties Test Equipment

/

Gas Permeability Analyzer

/Differential Pressure Method Gas Transmission Tester N530 2.0

Differential Pressure Method Gas Transmission Tester N530 2.0

Introduction

N530 2.0 is based on the test principle of differential pressure method, It's designed with reference to GB/T 1038, ISO 2556 and other standards. Adopt high-precision pressure sensor and automatic pressure difference keeping technology, high test accuracy. It is suitable for the gas permeability test of films, sheets, papers, packages and related materials in the fields of food, medicine, medical equipment, daily chemicals, photovoltaic electronics, etc. It provides a wide range and high-efficiency gas transmission rate test of high, medium and low gas barrier materials.

  • Brand:

    GBPI
Inquiry now
Product Detail

Test Principle

According to the principle of differential pressure method. Place the processed sample between the upper and lower chambers, use a vacuum pump to evacuate the entire gas circuit system, and then add an experimental gas of an atmospheric pressure to the upper chamber to form a constant pressure difference between the upper and lower chambers. Under the pressure gradient, the gas permeates from the upper chamber to the lower chamber through the membrane, then the system can calculate the barrier performance parameters such as the gas permeability of the sample through the pressure change of the lower chamber.

 

 

Standards

ISO 2556, ISO 15105-1, ASTM D1434, JIS K7126-1, YBB 00082003, GB/T 1038

 

Specifications

 

 

Item Technical Parameters
Testing Range 0.01 - 50000 cm³/(m²·24 h·0.1 MPa). By expanding the upper limit of the volume, it can test up to 600000 cm³/(m²·24h·0.1MPa)
Resolution 0.0001 cm³/(m²·24 h·0.1 MPa)
Temperature Control Range 15 - 60℃
Temperature Control Precision ±0.1℃
Vacuum Degree <10 Pa
Vacuum Resolution 0.01 Pa
Testing Pressure 0.1 MPa
Testing Gas O2, CO2, N2, etc.
Permeation Area 50.24 cm²
Specimen Size Φ110 mm
Specimen Thickness ≤2 mm
Number of Specimens 3 pieces
Overall Dimensions 690 mm620 mm390 mm
Weight 55 kg
Power 750 W
Power Supply AC 220V, 50Hz

 

 

 

Features

 Patented core technology for efficient and accurate testing

Patented automatic pressure differential technology, which automatically maintains the pressure difference between the two sides of the sample (the pressure differential can be adjusted freely), good stability and low failure rate due to a built-in high-precision pressure sensor with a resolution of 0.01 Pa.

The semi-conductor refrigeration sheet can control the temperature bidirectionally and automatically, the control accuracy reach to 0.1°C.

Original imported vacuum pump with high vacuum efficiency and low noise, the ultimate pressure can reach 0.1 Pa.

The new pneumatic air circuit control system, Excellent sealing performance that sample can be locked by one-button style automatic fixture.

 High throughput, wide testing range and high applicability

The instrument is equipped with 3 chambers, which supports simultaneous testing of three identical or different samples, independent operation, independent data, and high test efficiency.

The testing minimum reach to 0.01 cm3/(m2·24 h·0.1 MPa), which can meet the test requirements of  high, medium and low barrier materials.

With the optional addition accessories, it can measure the gas transmission rate of bottles, bags, bowls and other packages. At the same time, it supports the permeability test of different gases such as oxygen, carbon dioxide, nitrogen, and air.

 Professional calibration service with accurate and reliable data

 

Our company has the "National Standard Substance Grading Certificate" for gas transmission rate approved and issued by the "General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China", the standard substance number (GBW(E) 130541 / GBW(E) 130542); The national standard material is used to calibrate and test the instrument to ensure the accuracy, versatility and authority of the test data.

 

Application

 

Films

Various plastic films (PP/PET/PE/PVC/BOPP/CPP, etc.), plastic composite films, paper-plastic composite films, metal composite films, co-extruded films, aluminized films, degradable packaging films (PLA/PBAT/PBS etc.) and other membranous materials

 

Sheet

Solid medical hard sheet (PP/PVC/PTP, etc.), metal composite sheet, rubber sheet and other sheet materials

 

Paper and cardboard

Coated paper, carbon paper, silicone paper, aluminized paper, paper-aluminum-plastic composite sheet and other paper, cardboard

 

Medicinal patch, warmer patch

Medical plaster treatment patch, warm patch, dysmenorrhea patch, etc.

 

Hygiene

Sanitary napkins, pads and other hygiene products

 

Package

Wine bottles, Coke bottles, peanut oil drums, Tetra Pak packaging, vacuum packaging bags, three-piece cans, cosmetic packaging, toothpaste tubes, jelly cups, yogurt cups, etc. Plastic, rubber, paper, paper-plastic composite, glass, metal bottles Gas transmission rate test of bags, cans, boxes and drums

 

Gases

Oxygen, carbon dioxide, nitrogen, air, helium, etc.

 

 

Send A Message

Leave us a message, we will get back to you ASAP.

Related Products
Gas Permeability Analyzer N500 2.0 Gas Permeability Analyzer
Introduction Based on the test principle of the differential pressure method, N530 is designed with reference to the GB/T 1038 standard and used to test the gas transmission rate (quantity) of film or sheet materials.
Gas Permeability Analyzer N530 L Gas Permeability Analyzer
Introduction Based on the test principle of the differential pressure method, N530L is designed with reference to the GB/T 1038 standard and used to test the gas transmission rate (quantity) of film or sheet materials.
Gas permeation testing Gas Permeability Testing Differential Pressure Method N500L
Product Introduction This product is based on the test principle of the differential pressure method, and is designed and manufactured with reference to ASTM D1434, ISO 2556 and other standards. With high-precision pressure sensor and automatic differential pressure maintaining technology, this machine has high test accuracy. It is suitable for the gas permeability test of films, sheets, paper, packaging and related materials in food, medicine, medical equipment, daily chemicals, photovoltaic electronics and other industries. It can be used to test high, medium and low gas barrier materials with outstanding efficiency.
tensile strength tester Flexible packaging film tensile properties measurement by tensile tester
To test the tensile strength, peeling strength, heat sealing strength and tearing strength of plastic film, composite film, tape, soft packaging material, rubber sheets, paper, non-woven fabrics and other packaging materials, widely used in industries of membrane, packaging, pharmaceuticals, food, inspection agency, research institute, college and so on.
Aluminum Foil Testing Machine GNP-1 Aluminum foil bursting strength tester
Application GNP-1 Bursting Strength Tester can measure the bursting strength of single-layer or multi-layer paper, and can be used to test the blasting strength of cloth, leather, paper board, thin metal sheet, etc. Use mark transmission pressure, automatically retain the maximum bursting strength value when bursting, decomposition degree is 100 times higher than the needle type.
Exhalation Valve Air Tightness Tester Medical Mask Exhalation Valve Air Tightness Tester - GB-HQ1000
Medical Mask Exhalation Valve Air Tightness Tester  is Used to detect the air tightness of the mask breath valve. GBPI offers mask testing machines for surgical face masks, N95 masks, Melt-blown fabric. BFE Tester, PFE Tester, N95 Tester, Melt-blown fabric Tester      
Headspace Gas Analyzer Headspace Gas Analyzer-GB-DK
Product Introduction The headspace gas analyzer adopts the destructive puncture detection method and is equipped with high-precision oxygen sensors and carbon dioxide sensors to accurately detect the O2 and CO2 content of hollow packaging containers such as packaging bags, bottles, cans, etc. The analysis of the content of the headspace gas in the packaging can make a reasonable judgment on the product quality, the validity of the shelf life prediction, and the rationality of the packaging design. At the same time, it can also be used as a means of packaging tightness testing. It is a better choice for modified atmosphere preservation (MAP, CAP) packaging, large infusion bottles (bags), residual oxygen in the headspace of prefilled needles, residual oxygen detection in vials, and the results of residual oxygen detection for various food and medicines. Nowadays, the headspace gas analyzer has become an important method to check the quality of packaging design and one of the important methods to verify the product shelf life. Our headspace gas analyzer GB-DK can quickly detect O2 in production lines, warehouses, laboratories and other occasions. And CO2 content to guide production.   Test principle The gas in the sample is drawn into the sensor by a vacuum pump. The sensor outputs the current and voltage signals of the O2 and CO2 (optional) concentration in the gas in the sample in real time. The instrument calculates the content of O2 and CO2 in the gas by obtaining the current and voltage signals output by the sensor. After reaching the end conditions of the experiment, the test stops, and the instrument records the concentration of O2 and CO2 in the measured gas in the sample.   Technical parameter Item Parameter Gas to be Measured O2 (standard configuration) CO2 (optional) Measurement Principle Fluorescence optics infrared absorption Measurement Range 0%~25% (for O2) 0%~100% (for CO2) Measurement Accuracy ±0.2% ±2% Sample Size ≥5 mL (at standard atmospheric pressure) (for O2) ≥20 mL (at standard atmospheric pressure) (for CO2) Dimensions 350 mm (L)×330 mm(W)×200 mm(H) Power Supply 220 VAC±10 % 50Hz/120 VAC±10 % 60 Hz Net Weight 5kg    Features 1.Using high-precision sensors, high accuracy, good stability, long-term operation, long service life. Over-range automatic protection function to avoid damage to important sensors when the instrument fails. 2.The needle/probe safety holster is used to ensure safe testing and fast sampling. 3.Oxygen and carbon dioxide can be detected at the same time, and carbon dioxide gas can be selected for analysis according to different user needs. The sampling volume is at least 3 ml. 4.Built-in operating system, the system is equipped with an ARM control system to control the host through a touch screen (testing equipment and control software are combined into one); at the same time, the system can be expanded, such as connecting to the laboratory LIMS system. 5.The software is designed according to the requirements of the computerized system in the new version of the GMP appendix, and users are divided into multiple levels such as operators and administrators (such as administrators, operators, observers, etc. but not limited to these levels). 6.It has the audit trail function, which can realize the audit trail of the system, project operation, and method to ensure the safety and integrity of the test data. 7.Personalize the test report, set the report module that needs to be displayed, and output the report in PDF mode. The micro printer can print test reports in real time.  
Thickness Tester Plastic Film Digital Thickness Tester
Didital thickness tester is used to make thickness measuring or comparative measuring of plastic film, thin sheet, paper and so on.
Professional 8800XE Equal - Power Diesel Silent Generator supplier 8800XE Equal - Power Diesel Silent Generator
Product Introduction This portable diesel silent generator is designed for outdoor industrial emergency power supply. Adopting air - cooled four - stroke technology, it features stable performance, durability, strong power, high efficiency, intelligent protection, and low noise reduction, making it an ideal choice for various power - demanding scenarios. Product Parameters Name Details Model of Power 220 Rated Power 6.0kw (220V); 8.75kw (380V) Voltage 220V; 380V Fuel Tank Capacity 12.5L (220V); 15L (380V) Engine Oil Capacity 1.65L Weight 158kg Displacement 499cc Size 910530740mm Working Ambient Temperature ≤40°C Voltage Distortion Rate ≤10% DC Voltage 12V DC Current 8.3A Starting Method Electric start   Product Applications Industrial Power Generation Suitable for power supply in industrial factories, providing stable electricity to support production lines and various industrial equipment operations. Power for Aquaculture Can be used in aquaculture farms, ensuring continuous power for environmental control systems, feeding equipment, etc., to maintain the normal growth environment of aquatic products. Outdoor Construction Ideal for outdoor construction sites, supplying power for construction machinery, lighting, and other equipment, ensuring the smooth progress of construction projects.
Elmendorf tearing strength tester GBD-S ASTMD689 Elmendorf Tearing Strength Tester For Fabric And Paper
The tear tester (elemendorf method) tests the tear resistance of paper, film, PVC, polyolefin, polyester, composite film, sheet, non-woven fabric, textile, paper, and board, etc. It is controlled by computer automatically and can be tested independently.
Atmosphere Refrigerator AUTO GQ900 Modified Atmosphere Refrigerator
AUTO GQ-900 Modified Atmosphere Refrigerator is mainly for a variety of fruits, vegetables, flowers, seedlings, etc. on the market for storage and preservation tests, through microelectronics technology to automatically control the concentration of oxygen, nitrogen, carbon dioxide, ethylene in the box, as well as control temperature, humidity conditions to achieve the preservation effect, is a microorganism, environmental protection, food production, universities, scientific research institutions and other units indispensable ideal equipment.
Professional W416 2.0 Water Vapor Transmission Rate Tester supplier W416 2.0 Water Vapor Transmission Rate Tester
W416 2.0 Infrared Water Vapor Transmission Rate Tester High Precision WVTR Tester | 6 Independent Test Chambers Product Introduction W416 2.0 Infrared Water Vapor Transmission Rate Tester is an upgraded high-end precision testing instrument developed by GBPI R&D team in accordance with GB/T 26253, ASTM F1249 and international standards. Based on infrared moisture sensor technology, it provides wide-range and high-efficiency WVTR test for high, medium and low barrier materials. It is widely used for films, sheets, paper, packages and materials in food, pharmaceutical, medical devices, daily chemical, photovoltaic and electronics industries, ideal for offline and online testing in packaging industry. Get a Free Quote Today   Test Principle W416 2.0 adopts the infrared sensor testing principle. The pre-processed sample is fixed in the test chamber, dividing it into wet and dry sides. Compressed air flows in the wet chamber, and dry nitrogen (carrier gas) flows in the dry chamber at a fixed rate. Due to humidity gradient, water vapor permeates to the dry chamber and is carried to the infrared sensor. The WVTR value is calculated by the electrical signal output from the sensor.   Compliant Standards ISO 15106-2 ISO 21760-1 ASTM F1249 GB/T 26253 JIS K7129-2 Chinese Pharmacopoeia 4010 YBB 00092003   Technical Specifications Item Value Test Range 0.002~100 g/(m²·24h) Repeatability 0.005 or 2% (whichever is greater) Resolution 0.0001 g/(m²·24h) Temperature Range 15~45℃ Temperature Accuracy ±0.1℃ Humidity Range 5~90%RH, 100%RH Humidity Accuracy ±1%RH Test Area 50.24 cm² Sample Size Φ100 mm Sample Thickness ≤3 mm Test Chambers 6 channels (independent data)   Key Features Patented high-precision infrared moisture sensor, ultra-high stability, resolution up to 0.0001 g/(m²·24h). Automatic pneumatic control system, one-key sample clamping, excellent sealing and easy operation. Precise temperature & humidity control: ±0.1℃, ±1%RH, stable and reliable test data. 6 independent test chambers for high-throughput and high-efficiency testing. Real-time display of 5 test curves: WVTR-time, temperature-time, humidity-time, flow-time, voltage-time. Intelligent OS with audit trail, multi-level user rights, fully compliant with GMP. Calibrated with national standard substances (GBW(E)130543 / GBW(E)130544) for authoritative data. Support laboratory intelligent IoT platform: remote data management, remote diagnosis, resource download.   Applications Plastic Films PET, PE, BOPP, composite films, degradable films, aluminum-plated films, etc. Sheets Pharmaceutical rigid sheets, metal composite sheets, rubber sheets, etc. Paper & Paperboard Coated paper, aluminum paper, paper-plastic composite materials, etc. Medical Patches Medical plasters, transdermal patches, healthcare dressings, etc. Packaging Components Bottles, tubes, trays, bags, plastic containers, etc.
  • Facebook
  • Linkedin
  • Youtube
  • Twitter

Copyright @ 2026 Guangzhou Biaoji Packaging Equipment Co.,Ltd. All Rights Reserved.

Chat now

Inquiry Now

Home

Products

NEWS

contact