Spectrophotometer ST50 is a spectrophotometer developed by GBPI series core technology, using built-in photodiode array (double 20 groups) sensors, imported whiteboard, while taking into account the measurement speed and convenience of operation. The repeatability delta E* AB of ST50 spectrophotometer is easily controlled within 0.03, and the Inter-instrument error delta E* AB is controlled within 0.2, to make the measurement more accurate. And the test data can be used for accurate color analysis and transmission in the laboratory.

Application 

Spectrophotometer ST50 is equipped with one customized measuring aperture, accurate color measurement and stable performance. It is used for accurate color measurement and quality control in plastic electronics, paint ink, textile and garment printing and dyeing, printing, ceramics and other industries, and can be used for fluorescent sample measurement.

 

Features 

1. Large area photodiode array (dual 20 arrays) sensor 

A larger area of double 20 array sensor, strong light saturation, weak light sensitivity and a wider spectrum response range, to ensure the instrument measurement speed, accuracy, stability and consistency, independent core technology, and international standards of the same platform, to achieve complete compatibility.

1. Adopt D/8 structure and SCI/SCE mode 

Spectrophotometer ST50 uses a widely international use D/8 optical structure, SCI/SCE (Specular Component Included/Specular Component Excluded) synthesis technology, support SCI+SCE at the same time fast measurement, test time about 1.5 seconds. 

2. Combination of full spectrum LED light source and UV light source

The use of 400-700nm full spectrum LED light source ensures sufficient spectral distribution in the visible light range, avoiding the spectral loss of specific bands, strong light will not be saturated, weak light is more sensitive, and fluorescence samples can be easily measured.

4. Camera positioning can clearly observe the measured area 

The ST50 spectrophotometer has built-in camera. Through the real-time scene-taking of the camera, it can accurately determine whether the measured part of the object is the target center, which improves the measurement efficiency and accuracy.

Send A Message

Leave us a message, we will get back to you ASAP.

Related Products
Professional SGW-810 Light Transmittance and Haze Tester Haze ASTM D1003 supplier SGW-810 Light Transmittance and Haze Tester Haze ASTM D1003
Application Use for test the light transmittance and haze degree of all transparent and semi-transparent parallel plane samples (plastic plate, sheets etc), and turbidity or clarity of liquid samples (water, drinks etc), used in the industries of plastics, membrane, coatings and paints, printing ink, research institute and so on.
Optical Properties Testing P60 Standard Light Source Optical Properties Testing
P60 Standard Light Source Used for color observation, color contrast and color matching in a wide range of industries of printing, paints, printing ink, plastics, dyeing and so on.
Grating Spectrophotometer Densitometer GBPI Grating Spectrophotometer Densitometer
1.Perfect combination of the beautiful appearance and the ergonomic structure design; 2.Combined LED light sources with long life and low power consumption, including UV light; 3.Switchable apertures: Φ2/4/8mm, adapt to more samples; 4. Accurately measure reflectance spectrum, CMYK density and Lab value of the sample; 5.High-configuration electronic hardware: 3.5-inch TFT true-color screen, capacitive touch screen, concave grating, 256-pixel dual-array CMOS image sensor, etc.; 6.Two standard observer angles: 2/10, multiple light source modes and color systems; 7.USB mode is widely used. 8.Large-capacity storage space, over 10,000 test data; 9.Especially suitable for process control and quality control of printing plants;10. PC software has powerful function expansion.
YH1200 haze meter GBPI Spectrophotometer (Core Technology)
  Introduction GBPI haze meter can easily achieve ASTM D1003 non-compensation method, ISO 13468 compensation method, full light transmittance,haze test.Open sample bin can be vertically and horizontally tested to accommodate more samples to be tested.The YH1200 haze meter uses a PD array detector to meet the CIE V(λ)2 degree visual response. The compensation method can be used to measure the light transmittance and haze with high precision and repeatability.   Technical Advantage 1.Double standard ISO&ASTM Able to meet the test standard requirements of different users, in accordance with ASTM D1003/1044,ISO 13468,ISO 14782,GB/T 2410,JJF 1303-2011,CIE 15.2,JIS K7105,JIS K7361,JIS K 7136   2.Easy to operate, faster and more accurate measurement The YH1200 haze meter is equipped with a large-size touch screen for easy operation.With a PD array detector, CIE V(λ)2 degree visual response enables high precision and repeatable transmittance and fog measurements.USB data output device for docking with laboratory system.   3.Dynamic measurement Independent light source detector and temperature sensor, constantly monitor light source and environmental change, ensure the reliability of test data.   4.With compensation port, so that the measurement data more accurate Meet ASTM D1003 non-compensation method, ISO 13468 compensation method, full light transmittance, fog test, provide more accurate test results.   5.Easy to measure and widely applicable to samples Open measuring area, vertical and horizontal testing, suitable for more samples to be tested.   6.Quality control software It provides powerful software for measuring and analyzing fog and light transmittance, which is suitable for quality monitoring and tabulated management of fog and light transmittance data in various industries.The management of users will be digitized at the PC end, the difference of fog and light transmittance will be compared, and the test report form will be generated to facilitate customer customization and management.   Application YH1200 haze meter is widely used in glass processing, plastic processing, film processing, screen processing, packaging industry, liquid pharmaceutical analysis and other aspects.   Specification Product Model GBPI Haze Meter Optical Geometry Transmittance:0/D (Parallel light illumination, diffuse viewing); Conform to the standards: ASTM D1003/1044,ISO 13468,ISO 14782,GB/T 2410,JJF 1303-2011,CIE 15.2,JIS K7105,JIS K7361,JIS K 7136 Characteristic The instrument can easily achieve ASTM D1003 non-compensation method, full light transmittance,haze test. Open measuring area for vertical and horizontal testing. In glass processing, plastic processing, film, screen processing, packaging and other industries are widely used in transmittance,haze detection. Integrating Sphere Size Φ154mm Light Source 400nm to 700nm, combined LED light Spectrophotometric Mode / Sensor The PD array detector satisfies CIE V(λ)2 degree visual response Wavelength Range / Wavelength Interval / Semiband Width / Measurement range 0~100% Measuring Aperture Φ20mm/Φ15mm/Φ8mm/Φ4mm(Select a single aperture) Sample Size Thickness <170mm Color Space / Color Difference Formula / Other Colorimetric Index Haze(ASTM D1003/1044,ISO13468),Transmittance T(ISO),Transmittance T(ASTM) Observer Angle 2° Illuminant D65,A,C Displayed Data PASS/FAIL Result Measuring Time About1.5s Resolution 0.01unit Repeatability Φ20mm,within 0.05 (After preheating and calibration of the instrument, standard deviation values of standard haze tablets with a test haze of about 30 for 30 times were taken at intervals of 5s.) Inter-instrument Error Φ20mm,with 0.4 (After the instrument is preheated and calibrated, the standard deviation between the standard haze tablet and the reference value is tested at an interval of 5s.) Dimension L*W*H=290X211X511mm Weight About7.6kg Power AC 24V, 3A Power adapter power supply Illuminant Life Span 5 years, more than 3 million times measurements Display 7-inch TFT color LCD, Capacitive Touch Screen Data Port USB, Print serial port Data Storage Standard 1000 pcs,sample 20000 pcs Language Simplified Chinese,Traditional Chinese,English Operating Environment 0~40℃(32~104°F) Storage Environment -20~50℃(-4~122°F) Standard Accessory Power Adapter, User Guide,Quality Management Software (download from the official website),USB cable,0% calibration box, measuring aperture. Optional Accessory Micro-printer,Test fixture, standard haze sheet, foot switch Note: The specifications are subject to change without notice.      
Portable Digital Gloss Meter KGZ 1C Intelligent Gloss Tester
  Application used to detect the gloss of plastic film, paper, ink, adhesive, etc. Multi-point measurement and data processing can be performed on the sample, and parameters such as average value, standard deviation and coefficient of variation can be printed directly. The machine has high precision and good stability, and can measure the glossiness of flat products such as paint, paper, plastic, ceramic, stone and metal.   Feature  Full-function intelligent design, light touch key operation.  Automatic measurement and manual measurement function.  For single point or no more than 10 points measurement, calculate the average value, root mean square, coefficient of variation and print out the result.   Standards  Angle International Standard Chines Standard Application 20 ISO-2813 ISO8254 GB9754 GB8807 Coating Plastic 20 TAPPI-T653 ASTM-D1834 GB8941.1 Paper 45 ISO-2767 GB8941.2 Metal compound paper 45 ASTM-C346 ASTM-D2457 GB8807 Ceramics、Plastic 45 JIS-E8741   Coating 60 ISO-2813 ASTM-D2457 GB9754 GB9966 GB8807 Coating Stone Plastic 75 TAPPI-T480 GB9841.3 Paper 85 ISO-2813 GB9754 Coating   Specifications Item Specification Test range 0-199.9 Gloss units Precision ±1.0 Gloss units Stability Not more than 0.5 gloss unit / every 30 minutes Repeatability Not more than 0.5 gloss unit Measuring probe size 180mm×100mm×50mm Power 25w/ 220vAC,50HZ      
aluminum film Vacuum Coating Thickness Tester Vacuum Coating Thickness Tester For Vacuum Aluminum Film GH-E
Vacuum Coating Thickness Tester is applied to various vacuum aluminum film, aluminized paper, and other conductive coating materials to test the resistance value, evenness, thickness and so on.
Oxygen Permeability Analyzer Y110 L Oxygen Permeability Analyzer - Coulometric Sensor Method
This product is based on the testing principle of coulometric oxygen sensor, designed and manufactured with reference to ASTM D3985 and other standards. It adopts high-precision imported oxygen sensor with high testing accuracy. It is suitable for oxygen transmission performance testing of films, sheets, papers, packaging and related materials in the fields of food, pharmaceuticals, medical devices, daily chemicals, photovoltaic electronics, etc. It provides wide range and high efficiency oxygen transmission rate testing for high, medium and low oxygen barrier materials.
Moisture permeation rate tester Water Vapor Permeability Analyzer For LDPE Film Gravimetric Method - W533
A533 water vapor permeability analyzer is to test the water vapor transmission rate (WVTR) of films or sheets materials.
spout insert and sealing machine Three-station Rotary Mode Spout Sealing Machine (Three-station)
Product introduction The automatic three-station rotary mode spout sealing machine is specially designed for automatic sleeving and heat sealing of straws and bags. It is suitable for straws of various calibers, lengths and models, and is the preferred automated equipment for spouted stand-up pouches in beverage packaging, drinkable jelly, condiments, and daily chemical products (laundry detergent, skin care products, etc.). It can be customized to connect with filling production lines.
Professional GB-ML Packaging Leakage Tester ASTM D3078, GB/T 15171 supplier GB-ML Packaging Leakage Tester ASTM D3078, GB/T 15171
  Product Introduction     The GB-ML Leakage Tester is a professional testing instrument powered by compressed air, which controls the lifting and lowering of the sealing barrel lid through an air cylinder.   Adopting a high-precision electronic pressure sensor and a microcomputer control system, it effectively compares and evaluates the sealing process and sealing performance of flexible packages, and provides a scientific basis for determining relevant technical requirements.   This equipment is suitable for sealing performance testing of flexible packages in food, pharmaceutical, daily chemical and other industries.   Testing Principle   The sample is immersed in water, and a vacuum is applied to the vacuum chamber to create a pressure difference between the inside and outside of the sample.   The sealing performance is judged by observing gas escaping from the sample or water penetrating into the sample.     Applicable Standards   GB/T 15171, ASTM D3078-2002 (2013), USP 1207.2 Item Technical Parameters Vacuum Degree 0~-90 kPa Vacuum Accuracy ±1% of indicated value Vacuum Holding Time 0.01 s~99.99 h Sealing Barrel Size Standard: Φ600×591 mm; other sizes optional or customizable Effective Vacuum Chamber Size Standard: Φ550×396 mm; other sizes customizable Air Inlet Pressure 0.6~0.8 MPa Power 50 W Instrument Dimensions 1005×802×1307 mm Power Supply 220 V, 50 Hz   Product Features   High-quality components, stable and reliable   Built-in high-precision pressure sensor with high sensitivity, enabling real-time monitoring of inlet pressure.   Full-automatic operation system   Vacuum degree and holding time can be set as required. The instrument automatically completes vacuuming, holding, stopping and air-releasing.   Brand-new pneumatic system with fast inflation and return, achieving balanced pressure inside and outside.   Key-controlled cylinder for automatic opening and closing of the sealing barrel lid, labor-saving and convenient.   Supports multiple test methods   Supports bubble method and dye penetration method for leakage / integrity testing.     Application Areas   Plastic Packaging   Leakage testing for plastic bags, plastic containers (bottles, cans, boxes), etc.   Glass Packaging   Leakage testing for food bottles, pharmaceutical glass containers, daily chemical glass bottles, etc.   Metal Packaging   Leakage testing for cans, easy-open cans, aerosol cans, metal hoses, etc.   Other Applications
Portable Digital Gloss Meter KGZ 1C Intelligent Gloss Tester
  Application used to detect the gloss of plastic film, paper, ink, adhesive, etc. Multi-point measurement and data processing can be performed on the sample, and parameters such as average value, standard deviation and coefficient of variation can be printed directly. The machine has high precision and good stability, and can measure the glossiness of flat products such as paint, paper, plastic, ceramic, stone and metal.   Feature  Full-function intelligent design, light touch key operation.  Automatic measurement and manual measurement function.  For single point or no more than 10 points measurement, calculate the average value, root mean square, coefficient of variation and print out the result.   Standards  Angle International Standard Chines Standard Application 20 ISO-2813 ISO8254 GB9754 GB8807 Coating Plastic 20 TAPPI-T653 ASTM-D1834 GB8941.1 Paper 45 ISO-2767 GB8941.2 Metal compound paper 45 ASTM-C346 ASTM-D2457 GB8807 Ceramics、Plastic 45 JIS-E8741   Coating 60 ISO-2813 ASTM-D2457 GB9754 GB9966 GB8807 Coating Stone Plastic 75 TAPPI-T480 GB9841.3 Paper 85 ISO-2813 GB9754 Coating   Specifications Item Specification Test range 0-199.9 Gloss units Precision ±1.0 Gloss units Stability Not more than 0.5 gloss unit / every 30 minutes Repeatability Not more than 0.5 gloss unit Measuring probe size 180mm×100mm×50mm Power 25w/ 220vAC,50HZ      
Salt Spray Tester Salt spray test chamber GB-OSH-60
  1. FunFunction Salt spray test chamber is used for the quality inspection and corrosion resistance test of a variety of materials, including metal plating, metal, electronic components, chemical coatings, paint, automobiles, motorcycles, metal ware, screws, springs, magnetic materials, organic and inorganic coating, anodizing, anti-rust oil industry etc. after the surface treatment.   1. ecGTechnical parameters   1. MODEL GB-OSH-60 2. Temperature inside chamber 35℃±1℃/ 50℃±1℃ 3. Temperature of pressure barrel 47℃±1℃/ 63℃±1℃  4. Inner size W600 x H400 x D450mm   5. External size W1080 x H1080 x D650mm 6. Temperature Uniformity ≤±2℃ 7. Uniformity Fluctuation ≤±0.5℃ 8. Salt fog settlement 1~2ml/h.80cm2 9. Compressed air pressure 1.00±0.01kgf/cm² 10. Spray mode Continuous or intermittent spray optional 11. Power supply AC  220V   50Hz   1.5KW a)  Temp. range: RT+10℃ ~ 55℃ (temperature up to 50C, thickening PVC or PP material is recommended ) b) Humid. range: ≥93%R.H c) Controller time shown: 9.9s~9990hrs d) Timer: 0~9999hrs. e) Testing method: Neutral salt spray test (NSS test), acetic acid salt spray test (AASS test), salt spray test (SS test), copper accelerated acetic acid salt spray test method for salt spray test (CASS test) and so on; (For CASS test, we recommend the PP material chamber with high temperature resistance) f) Specimen holder: It can meet the tilt test at 15 ℃ ~ 30 ℃ (two layers); g) Air compressor: V-0.013/12.5(Customer provided); discharge pressure:1.25M; flow amount: 0.13m3/min   1. MMMaterial of machine body a) Salt spray chamber adopts the quality PVC reinforced hard plastic plate, the surface is smooth and anti-aging, anti-corrosion; b) Without any FRP material produced on the surface because of discoloration fibrosis. Plastic structure of the chamber is better to meet strong acid salt spray test under long-term without any damage. c) Cover is imported transparent impact-resistant plate which is convenient to test specimen when test, that can cover and the box with a water seal to prevent leakage of salt spray.   2. AccAccording to CSN, JIS, ASTM standards, can be set to constant temperature control: (a) Brine spray test: NSS (neutral); · Temp. inside chamber: 35 ℃ ± 1 ℃ · Pressure air bucket: 47 ℃ ± 1 ℃ (b) Corrosion resistance test: CASS (copper acceleration), AASS (acid) · Temp. inside chamber: 50 ° C ± 1 ° C · Pressure air bucket: 63 ℃ ± 1 ℃   3. Watwatering system. It adopts the auto watering system, supply water when lack of water. 4. HeaHeating system Test temperature inside the cabinets is heated humidification water jacket, the heater adopts advanced titanium protective tube, built-in nickel-chromium alloy infrared heater core. Heating up fast, uniform temperature distribution; and saves about one half of the power compared to FRP tank jacketed heating. 5. ExeExecutive standard GB/T 2423.17 Basic test procedures for electric and electronic products Ka"- salt spray test methods; GB/T 10125 Corrosion tests in artificial atmospheres – salt spray tests; ASTM B368 Test Method for Copper-Accelerated Acetic Acid-Salt Spray (Fog) Testing (CASS Test); JIS Z2371-2000 Methods of salt spray testing etc. ISO 9227 Corrosion tests in artificial atmospheres (Note: 2 collection device is required, bigger models than ZH-SH-90 (270L) is required; In some versions, it specifies over 400liters is necessary)  ASTM B117-18 Standard Practice for Operating Salt Spray (Fog) Apparatus (Note: 2 collection device is required, bigger models than ZH-SH-90 is required )  
  • Facebook
  • Linkedin
  • Youtube
  • Twitter

Copyright @ 2026 Guangzhou Biaoji Packaging Equipment Co.,Ltd. All Rights Reserved.

Chat now

Inquiry Now

Home

Products

NEWS

contact