packaging testing equipment Water Vapor Permeation Tester
Products
Home /

Physical Property Test Equipment

/

Optical Tester

/GBPI ST50 Spectrophotometer

GBPI ST50 Spectrophotometer

Inquiry now
Product Detail

Spectrophotometer ST50 is a spectrophotometer developed by GBPI series core technology, using built-in photodiode array (double 20 groups) sensors, imported whiteboard, while taking into account the measurement speed and convenience of operation. The repeatability delta E* AB of ST50 spectrophotometer is easily controlled within 0.03, and the Inter-instrument error delta E* AB is controlled within 0.2, to make the measurement more accurate. And the test data can be used for accurate color analysis and transmission in the laboratory.

Application 

Spectrophotometer ST50 is equipped with one customized measuring aperture, accurate color measurement and stable performance. It is used for accurate color measurement and quality control in plastic electronics, paint ink, textile and garment printing and dyeing, printing, ceramics and other industries, and can be used for fluorescent sample measurement.

 

Features 

1. Large area photodiode array (dual 20 arrays) sensor 

A larger area of double 20 array sensor, strong light saturation, weak light sensitivity and a wider spectrum response range, to ensure the instrument measurement speed, accuracy, stability and consistency, independent core technology, and international standards of the same platform, to achieve complete compatibility.

1. Adopt D/8 structure and SCI/SCE mode 

Spectrophotometer ST50 uses a widely international use D/8 optical structure, SCI/SCE (Specular Component Included/Specular Component Excluded) synthesis technology, support SCI+SCE at the same time fast measurement, test time about 1.5 seconds. 

2. Combination of full spectrum LED light source and UV light source

The use of 400-700nm full spectrum LED light source ensures sufficient spectral distribution in the visible light range, avoiding the spectral loss of specific bands, strong light will not be saturated, weak light is more sensitive, and fluorescence samples can be easily measured.

4. Camera positioning can clearly observe the measured area 

The ST50 spectrophotometer has built-in camera. Through the real-time scene-taking of the camera, it can accurately determine whether the measured part of the object is the target center, which improves the measurement efficiency and accuracy.

Send A Message

Leave us a message, we will get back to you ASAP.

Related Products
Professional SGW-810 Light Transmittance and Haze Tester Haze ASTM D1003 supplier SGW-810 Light Transmittance and Haze Tester Haze ASTM D1003
Application Use for test the light transmittance and haze degree of all transparent and semi-transparent parallel plane samples (plastic plate, sheets etc), and turbidity or clarity of liquid samples (water, drinks etc), used in the industries of plastics, membrane, coatings and paints, printing ink, research institute and so on.
Optical Properties Testing P60 Standard Light Source Optical Properties Testing
P60 Standard Light Source Used for color observation, color contrast and color matching in a wide range of industries of printing, paints, printing ink, plastics, dyeing and so on.
Grating Spectrophotometer Densitometer GBPI Grating Spectrophotometer Densitometer
1.Perfect combination of the beautiful appearance and the ergonomic structure design; 2.Combined LED light sources with long life and low power consumption, including UV light; 3.Switchable apertures: Φ2/4/8mm, adapt to more samples; 4. Accurately measure reflectance spectrum, CMYK density and Lab value of the sample; 5.High-configuration electronic hardware: 3.5-inch TFT true-color screen, capacitive touch screen, concave grating, 256-pixel dual-array CMOS image sensor, etc.; 6.Two standard observer angles: 2/10, multiple light source modes and color systems; 7.USB mode is widely used. 8.Large-capacity storage space, over 10,000 test data; 9.Especially suitable for process control and quality control of printing plants;10. PC software has powerful function expansion.
YH1200 haze meter GBPI Spectrophotometer (Core Technology)
  Introduction GBPI haze meter can easily achieve ASTM D1003 non-compensation method, ISO 13468 compensation method, full light transmittance,haze test.Open sample bin can be vertically and horizontally tested to accommodate more samples to be tested.The YH1200 haze meter uses a PD array detector to meet the CIE V(λ)2 degree visual response. The compensation method can be used to measure the light transmittance and haze with high precision and repeatability.   Technical Advantage 1.Double standard ISO&ASTM Able to meet the test standard requirements of different users, in accordance with ASTM D1003/1044,ISO 13468,ISO 14782,GB/T 2410,JJF 1303-2011,CIE 15.2,JIS K7105,JIS K7361,JIS K 7136   2.Easy to operate, faster and more accurate measurement The YH1200 haze meter is equipped with a large-size touch screen for easy operation.With a PD array detector, CIE V(λ)2 degree visual response enables high precision and repeatable transmittance and fog measurements.USB data output device for docking with laboratory system.   3.Dynamic measurement Independent light source detector and temperature sensor, constantly monitor light source and environmental change, ensure the reliability of test data.   4.With compensation port, so that the measurement data more accurate Meet ASTM D1003 non-compensation method, ISO 13468 compensation method, full light transmittance, fog test, provide more accurate test results.   5.Easy to measure and widely applicable to samples Open measuring area, vertical and horizontal testing, suitable for more samples to be tested.   6.Quality control software It provides powerful software for measuring and analyzing fog and light transmittance, which is suitable for quality monitoring and tabulated management of fog and light transmittance data in various industries.The management of users will be digitized at the PC end, the difference of fog and light transmittance will be compared, and the test report form will be generated to facilitate customer customization and management.   Application YH1200 haze meter is widely used in glass processing, plastic processing, film processing, screen processing, packaging industry, liquid pharmaceutical analysis and other aspects.   Specification Product Model GBPI Haze Meter Optical Geometry Transmittance:0/D (Parallel light illumination, diffuse viewing); Conform to the standards: ASTM D1003/1044,ISO 13468,ISO 14782,GB/T 2410,JJF 1303-2011,CIE 15.2,JIS K7105,JIS K7361,JIS K 7136 Characteristic The instrument can easily achieve ASTM D1003 non-compensation method, full light transmittance,haze test. Open measuring area for vertical and horizontal testing. In glass processing, plastic processing, film, screen processing, packaging and other industries are widely used in transmittance,haze detection. Integrating Sphere Size Φ154mm Light Source 400nm to 700nm, combined LED light Spectrophotometric Mode / Sensor The PD array detector satisfies CIE V(λ)2 degree visual response Wavelength Range / Wavelength Interval / Semiband Width / Measurement range 0~100% Measuring Aperture Φ20mm/Φ15mm/Φ8mm/Φ4mm(Select a single aperture) Sample Size Thickness <170mm Color Space / Color Difference Formula / Other Colorimetric Index Haze(ASTM D1003/1044,ISO13468),Transmittance T(ISO),Transmittance T(ASTM) Observer Angle 2° Illuminant D65,A,C Displayed Data PASS/FAIL Result Measuring Time About1.5s Resolution 0.01unit Repeatability Φ20mm,within 0.05 (After preheating and calibration of the instrument, standard deviation values of standard haze tablets with a test haze of about 30 for 30 times were taken at intervals of 5s.) Inter-instrument Error Φ20mm,with 0.4 (After the instrument is preheated and calibrated, the standard deviation between the standard haze tablet and the reference value is tested at an interval of 5s.) Dimension L*W*H=290X211X511mm Weight About7.6kg Power AC 24V, 3A Power adapter power supply Illuminant Life Span 5 years, more than 3 million times measurements Display 7-inch TFT color LCD, Capacitive Touch Screen Data Port USB, Print serial port Data Storage Standard 1000 pcs,sample 20000 pcs Language Simplified Chinese,Traditional Chinese,English Operating Environment 0~40℃(32~104°F) Storage Environment -20~50℃(-4~122°F) Standard Accessory Power Adapter, User Guide,Quality Management Software (download from the official website),USB cable,0% calibration box, measuring aperture. Optional Accessory Micro-printer,Test fixture, standard haze sheet, foot switch Note: The specifications are subject to change without notice.      
Portable Digital Gloss Meter KGZ 1C Intelligent Gloss Tester
  Application used to detect the gloss of plastic film, paper, ink, adhesive, etc. Multi-point measurement and data processing can be performed on the sample, and parameters such as average value, standard deviation and coefficient of variation can be printed directly. The machine has high precision and good stability, and can measure the glossiness of flat products such as paint, paper, plastic, ceramic, stone and metal.   Feature  Full-function intelligent design, light touch key operation.  Automatic measurement and manual measurement function.  For single point or no more than 10 points measurement, calculate the average value, root mean square, coefficient of variation and print out the result.   Standards  Angle International Standard Chines Standard Application 20 ISO-2813 ISO8254 GB9754 GB8807 Coating Plastic 20 TAPPI-T653 ASTM-D1834 GB8941.1 Paper 45 ISO-2767 GB8941.2 Metal compound paper 45 ASTM-C346 ASTM-D2457 GB8807 Ceramics、Plastic 45 JIS-E8741   Coating 60 ISO-2813 ASTM-D2457 GB9754 GB9966 GB8807 Coating Stone Plastic 75 TAPPI-T480 GB9841.3 Paper 85 ISO-2813 GB9754 Coating   Specifications Item Specification Test range 0-199.9 Gloss units Precision ±1.0 Gloss units Stability Not more than 0.5 gloss unit / every 30 minutes Repeatability Not more than 0.5 gloss unit Measuring probe size 180mm×100mm×50mm Power 25w/ 220vAC,50HZ      
gas generator High purity nitrogen hydrogen and air gas generator for gas chromatography
gas generator can generates high purity nitrogen, hydrogen and air; it can supply stable and high quality gas for Gas Chromatography
Atmosphere Refrigerator AUTO GQ100 Modified Atmosphere Refrigerator
  The AUTO GQ-100 Modified Atmosphere Refrigerator is meticulously engineered for storage and preservation tests of diverse fruits, vegetables, flowers, seedlings, and more. By harnessing microelectronics technology, it automatically regulates the concentrations of oxygen, nitrogen, carbon dioxide, and ethylene inside the refrigerator, along with temperature and humidity conditions, to achieve outstanding preservation effects. It is an essential and perfect equipment for microbiology, environmental protection, food production, universities, research institutions, and other relevant organizations.   Technical Parameters Project Technical Parameter Gas Measurement Range O₂: 0%–30%; CO₂: 0%–20%; C₂H₄: 0–220 ppm; Remaining gas: N₂ Gas Testing Accuracy O₂: 0.01%; CO₂: 0.01%; C₂H₄: 0.1 ppm Gas Purity Requirement Purity of O₂, CO₂, N₂, and C₂H₄ ≥ 99.9% Gas Flow Control O₂: 0–500 mL/min; CO₂: 0–500 mL/min; N₂: 0–500 mL/min Temperature Control Range -5°C–45°C Chamber Temperature Control Accuracy ±0.5°C Chamber Humidity Range Normal–95% RH Humidity Fluctuation Range ±3% RH Cooling Capacity 1 HP Chamber Humidifier Power 50 W Chamber Lighting System Power 10 W Material Colored steel plate Dimensions 889 mm × 1285 mm × 1750 mm Total Machine Power 1 KW Number/Volume of Test Chambers 1 chamber/100 L Power Supply AC 220V   Application   Fruit and vegetable storage and preservation It is suitable for the storage and preservation test of various domestic and imported fruits and vegetables.   Storage and preservation of meat and seafood It is suitable for storage and preservation test of various pork, beef, mutton and other meat and seafood products such as fish, shrimp, crab, etc.   Baked food storage and preservation It is suitable for the storage and preservation test of various bakery products such as bread, cakes and biscuits.   Storage and preservation of flowers and seedlings It is suitable for the storage and preservation test of various roses, lilies, phalaenopsis and other flowers and seedlings.   Product features Three test chambers work independently; Each chamber has its own humidity, flow and concentration of various gases, ethylene removal devices, lighting systems, sterilization systems, and drainage systems.  Built-in microcomputer system, automatic control, and automatic processing of data. Manually switch the cavity to display the temperature and humidity of each cavity, as well as the concentration of oxygen, nitrogen, carbon dioxide, ethylene, and so on.   24 inch 100,000 real color touch screen, can set the parameters of each cavity and control operations respectively; Detailed data and work status are displayed in real time.  Built-in ozone sterilization, manual button sterilization, can set the sterilization time.  Built-in ethylene catalytic removal device and gas displacement pump control ethylene concentration, fast degassing speed.  Imported high-precision sensors to detect various gas concentrations and ethylene concentrations. The sterilization system adopts ozone sterilization, the manual button for sterilization, automatic control of sterilization time, and automatic stop when the set time is reached. Temperature control: using heating wire heating, scroll compressor cooling, stable performance, low noise; PID algorithm with solid state relay control, no hard mechanical contacts, long service life, average temperature heating, constant temperature. The temperature control of each chamber adopts unified control, and the temperature of the three chambers is set manually. Humidity control: high-frequency atomization humidification, the humidification range is large, long-term humidification does not heat, does not affect the cavity temperature; Each chamber humidification system operates independently, automatically humidifies and maintains humidity after setting the humidity. The inner wall of each cavity is made of stainless steel, the special double-layer glass door, and the shell is made of special color steel plate.  Transparent windows, drainage system anti-condensation, built-in lighting, and self-entry box design.
Gas Permeability Tester Gas Transmission Rate Testing For Packaging Material
Gas transmission rate measurement of gas barrier films widely used as packaging for food, drink and medical products or sealing of electronic device
Gas Permeation Analysis Gas Permeation Analysis System GTR-10H
Product introduction The GTR-10H gas permeation analysis system consists of a differential pressure permeation device and a gas chromatograph. It can test and analyze the gas permeability of various single-component gases and mixed gases, and can accurately calculate the permeability, permeability coefficient and other parameters of each component gas. The test gas has a wide range of types and high accuracy, and is suitable for gas permeation testing in the fields of fuel cell proton exchange membrane gas permeability testing, hydrogen permeation of hydrogen storage materials, gas density of bipolar plate materials, and natural gas storage materials.   Test principle Place the processed sample between the high-pressure chamber and the low-pressure chamber, and the low-pressure chamber is connected to the gas chromatograph through a quantitative loop. At the set test temperature, use a vacuum pump to evacuate the gas system, and then add a certain pressure of test gas to the upper chamber to form a constant pressure difference between the upper and lower chambers. Under the action of the pressure gradient, the gas penetrates from the high-pressure chamber to the low-pressure chamber through the film. The system injects the gas that penetrates into the low-pressure chamber into the gas chromatography column and separates it into various components, and calculates the gas permeability, gas permeability coefficient and other barrier performance parameters of each component.   Standard GB/T 20042.3,GB/T 20042.6-2011,GB/T 1038.1-2022,ISO 15105-1   Specification Item Technical Parameters Test range 2.0×10-12~3.0×10-7 mol/(m2·s.Pa) Detection system Gas chromatography (GC), TCD detector Test gas Gases such as hydrogen, oxygen, nitrogen, carbon dioxide, carbon monoxide, methane, etc., single component or mixed component Gas pressure 0~300kPa Permeation module temperature control range 15~60℃ Temperature control accuracy ±0.1℃ Permeation area 50.24 cm2 Sample size Φ110 mm Sample thickness ≤2 mm Sample quantity 1 piece Power supply AC 220 V,50 Hz   Features Advanced gas chromatography analysis technology The instrument is equipped with an advanced gas chromatography analysis module and a new microcomputer temperature control system, which can achieve 16-step program temperature rise with high temperature control accuracy; it adopts multi-processor parallel working mode, and can be equipped with a variety of high-performance detectors. The instrument is stable and reliable, equipped with a 7-inch color LCD touch screen and a dedicated workstation, which is convenient to operate and easy to process data.   Fully automatic precision control of permeation module test temperature The permeation module uses semiconductor refrigeration chips to automatically control the temperature in both directions, with higher temperature control accuracy, up to 0.1℃.   Can test the permeability of single gas and mixed gas It can measure the permeability of a single gas and the permeability of different mixed gases at the same time, and has a wide range of uses. In addition to its application in the traditional packaging industry, it has broad application prospects in new energy fields such as hydrogen energy.   Intelligent operating system, global certification Self-developed intelligent operating system, modular graphics, flexible setting of test process parameters, and intuitive and convenient operation. Designed according to the GMP Appendix "Computerized System", it has an audit tracking function and multi-level user authority settings, which can meet the needs of the pharmaceutical industry for data traceability. Personalized test reports are set on demand, supporting data output in multiple formats, electronic signatures, and online submission of audit reports.   Laboratory Intelligent IoT Platform The instrument can be connected to the IoT platform to achieve digital network management. Remote authorization to log in to the IoT platform can achieve functions such as managing experimental data, remote diagnosis and troubleshooting. Customers can download the required instrument information, documents, and operation videos on the platform.
Ethylene Oxide Residuals Face Mask Ethylene Oxide (EO) Residuals Testing Gas Chromatography
GC9802-K Face Mask Ethylene Oxide (EO) Residuals Testing Gas Chromatography has a reasonable structure, stable and reliable performance, simple operation and convenient maintenance. Can be widely used in petroleum, chemical industry, pesticides, medicine and health, commodity inspection, environmental protection, universities and other production and scientific research departments. It can be used to detect ethylene oxide and other organic solvents. Detects purity or content of a single solvent
DSC Tester DSC100A DSC Testing Lab Differential Scanning Calorimeter
High Precision DSC Differential Scanning Calorimeter Product Introduction This DSC is our highest-precision differential scanning calorimeter. It is equipped with imported thermocouple sensors featuring ultra-high sensitivity. The signal acquisition circuit adopts full shielding protection design, delivering strong anti-interference capability and excellent baseline stability. Adopting touch screen operation, this instrument can perform glass transition temperature test, phase transition analysis, melting enthalpy measurement, product stability evaluation and oxidation induction period test, covering a wide range of testing applications. Test Principle By measuring the heat flow difference between the sample and the reference material under programmed temperature control, the instrument analyzes thermal characteristic parameters such as melting point, glass transition temperature and oxidation resistance of polymer, pharmaceutical and packaging materials. Technical Parameters Temperature Range Room Temperature ~ 550 ℃ (Air Cooling) Temperature Resolution 0.01℃ Temperature Fluctuation ±0.1℃ Temperature Repeatability ±0.1℃ Heating Rate 0.1~100℃/min Constant Temperature Duration Programmable ≤ 24h Temperature Control Modes Heating, Constant Temperature DSC Heat Flow Range 0~±600mW DSC Resolution 0.01μW DSC Accuracy 0.001mW Power Supply AC 220V, 50Hz (Customizable) Atmosphere Control Gas Nitrogen, Oxygen (Automatic Instrument Switching) Gas Flow Rate 0-300ml/min Gas Pressure 0.2MPa Display Screen 7-inch 24-bit Color LCD Touch Screen Data Interface Standard USB Port Calibration Standard Comes with Indium & Tin Reference Materials for User Self Temperature Calibration PC Software Compatibility 3-in-1 Host Software, Compatible with TGA & Synchronous Thermal Analyzers Thermocouple Configuration 3 Groups of Thermocouples: Sample Temp, Furnace Temp, Internal Ambient Temp Technical Features
Headspace Gas Analyzer Headspace Gas Analyzer-GB-DK
Product Introduction The headspace gas analyzer adopts the destructive puncture detection method and is equipped with high-precision oxygen sensors and carbon dioxide sensors to accurately detect the O2 and CO2 content of hollow packaging containers such as packaging bags, bottles, cans, etc. The analysis of the content of the headspace gas in the packaging can make a reasonable judgment on the product quality, the validity of the shelf life prediction, and the rationality of the packaging design. At the same time, it can also be used as a means of packaging tightness testing. It is a better choice for modified atmosphere preservation (MAP, CAP) packaging, large infusion bottles (bags), residual oxygen in the headspace of prefilled needles, residual oxygen detection in vials, and the results of residual oxygen detection for various food and medicines. Nowadays, the headspace gas analyzer has become an important method to check the quality of packaging design and one of the important methods to verify the product shelf life. Our headspace gas analyzer GB-DK can quickly detect O2 in production lines, warehouses, laboratories and other occasions. And CO2 content to guide production.   Test principle The gas in the sample is drawn into the sensor by a vacuum pump. The sensor outputs the current and voltage signals of the O2 and CO2 (optional) concentration in the gas in the sample in real time. The instrument calculates the content of O2 and CO2 in the gas by obtaining the current and voltage signals output by the sensor. After reaching the end conditions of the experiment, the test stops, and the instrument records the concentration of O2 and CO2 in the measured gas in the sample.   Technical parameter Item Parameter Gas to be Measured O2 (standard configuration) CO2 (optional) Measurement Principle Fluorescence optics infrared absorption Measurement Range 0%~25% (for O2) 0%~100% (for CO2) Measurement Accuracy ±0.2% ±2% Sample Size ≥5 mL (at standard atmospheric pressure) (for O2) ≥20 mL (at standard atmospheric pressure) (for CO2) Dimensions 350 mm (L)×330 mm(W)×200 mm(H) Power Supply 220 VAC±10 % 50Hz/120 VAC±10 % 60 Hz Net Weight 5kg    Features 1.Using high-precision sensors, high accuracy, good stability, long-term operation, long service life. Over-range automatic protection function to avoid damage to important sensors when the instrument fails. 2.The needle/probe safety holster is used to ensure safe testing and fast sampling. 3.Oxygen and carbon dioxide can be detected at the same time, and carbon dioxide gas can be selected for analysis according to different user needs. The sampling volume is at least 3 ml. 4.Built-in operating system, the system is equipped with an ARM control system to control the host through a touch screen (testing equipment and control software are combined into one); at the same time, the system can be expanded, such as connecting to the laboratory LIMS system. 5.The software is designed according to the requirements of the computerized system in the new version of the GMP appendix, and users are divided into multiple levels such as operators and administrators (such as administrators, operators, observers, etc. but not limited to these levels). 6.It has the audit trail function, which can realize the audit trail of the system, project operation, and method to ensure the safety and integrity of the test data. 7.Personalize the test report, set the report module that needs to be displayed, and output the report in PDF mode. The micro printer can print test reports in real time.  
  • Facebook
  • Linkedin
  • Youtube
  • Twitter

Copyright @ 2026 Guangzhou Biaoji Packaging Equipment Co.,Ltd. All Rights Reserved.

Chat now

Inquiry Now

Home

Products

NEWS

contact