packaging testing equipment Water Vapor Permeation Tester
Products
Home /

Physical Property Test Equipment

/

Optical Tester

/GBPI ST50 Spectrophotometer

GBPI ST50 Spectrophotometer

Inquiry now
Product Detail

Spectrophotometer ST50 is a spectrophotometer developed by GBPI series core technology, using built-in photodiode array (double 20 groups) sensors, imported whiteboard, while taking into account the measurement speed and convenience of operation. The repeatability delta E* AB of ST50 spectrophotometer is easily controlled within 0.03, and the Inter-instrument error delta E* AB is controlled within 0.2, to make the measurement more accurate. And the test data can be used for accurate color analysis and transmission in the laboratory.

Application 

Spectrophotometer ST50 is equipped with one customized measuring aperture, accurate color measurement and stable performance. It is used for accurate color measurement and quality control in plastic electronics, paint ink, textile and garment printing and dyeing, printing, ceramics and other industries, and can be used for fluorescent sample measurement.

 

Features 

1. Large area photodiode array (dual 20 arrays) sensor 

A larger area of double 20 array sensor, strong light saturation, weak light sensitivity and a wider spectrum response range, to ensure the instrument measurement speed, accuracy, stability and consistency, independent core technology, and international standards of the same platform, to achieve complete compatibility.

1. Adopt D/8 structure and SCI/SCE mode 

Spectrophotometer ST50 uses a widely international use D/8 optical structure, SCI/SCE (Specular Component Included/Specular Component Excluded) synthesis technology, support SCI+SCE at the same time fast measurement, test time about 1.5 seconds. 

2. Combination of full spectrum LED light source and UV light source

The use of 400-700nm full spectrum LED light source ensures sufficient spectral distribution in the visible light range, avoiding the spectral loss of specific bands, strong light will not be saturated, weak light is more sensitive, and fluorescence samples can be easily measured.

4. Camera positioning can clearly observe the measured area 

The ST50 spectrophotometer has built-in camera. Through the real-time scene-taking of the camera, it can accurately determine whether the measured part of the object is the target center, which improves the measurement efficiency and accuracy.

Send A Message

Leave us a message, we will get back to you ASAP.

Related Products
Professional SGW-810 Light Transmittance and Haze Tester Haze ASTM D1003 supplier SGW-810 Light Transmittance and Haze Tester Haze ASTM D1003
Application Use for test the light transmittance and haze degree of all transparent and semi-transparent parallel plane samples (plastic plate, sheets etc), and turbidity or clarity of liquid samples (water, drinks etc), used in the industries of plastics, membrane, coatings and paints, printing ink, research institute and so on.
Optical Properties Testing P60 Standard Light Source Optical Properties Testing
P60 Standard Light Source Used for color observation, color contrast and color matching in a wide range of industries of printing, paints, printing ink, plastics, dyeing and so on.
Grating Spectrophotometer Densitometer GBPI Grating Spectrophotometer Densitometer
1.Perfect combination of the beautiful appearance and the ergonomic structure design; 2.Combined LED light sources with long life and low power consumption, including UV light; 3.Switchable apertures: Φ2/4/8mm, adapt to more samples; 4. Accurately measure reflectance spectrum, CMYK density and Lab value of the sample; 5.High-configuration electronic hardware: 3.5-inch TFT true-color screen, capacitive touch screen, concave grating, 256-pixel dual-array CMOS image sensor, etc.; 6.Two standard observer angles: 2/10, multiple light source modes and color systems; 7.USB mode is widely used. 8.Large-capacity storage space, over 10,000 test data; 9.Especially suitable for process control and quality control of printing plants;10. PC software has powerful function expansion.
YH1200 haze meter GBPI Spectrophotometer (Core Technology)
  Introduction GBPI haze meter can easily achieve ASTM D1003 non-compensation method, ISO 13468 compensation method, full light transmittance,haze test.Open sample bin can be vertically and horizontally tested to accommodate more samples to be tested.The YH1200 haze meter uses a PD array detector to meet the CIE V(λ)2 degree visual response. The compensation method can be used to measure the light transmittance and haze with high precision and repeatability.   Technical Advantage 1.Double standard ISO&ASTM Able to meet the test standard requirements of different users, in accordance with ASTM D1003/1044,ISO 13468,ISO 14782,GB/T 2410,JJF 1303-2011,CIE 15.2,JIS K7105,JIS K7361,JIS K 7136   2.Easy to operate, faster and more accurate measurement The YH1200 haze meter is equipped with a large-size touch screen for easy operation.With a PD array detector, CIE V(λ)2 degree visual response enables high precision and repeatable transmittance and fog measurements.USB data output device for docking with laboratory system.   3.Dynamic measurement Independent light source detector and temperature sensor, constantly monitor light source and environmental change, ensure the reliability of test data.   4.With compensation port, so that the measurement data more accurate Meet ASTM D1003 non-compensation method, ISO 13468 compensation method, full light transmittance, fog test, provide more accurate test results.   5.Easy to measure and widely applicable to samples Open measuring area, vertical and horizontal testing, suitable for more samples to be tested.   6.Quality control software It provides powerful software for measuring and analyzing fog and light transmittance, which is suitable for quality monitoring and tabulated management of fog and light transmittance data in various industries.The management of users will be digitized at the PC end, the difference of fog and light transmittance will be compared, and the test report form will be generated to facilitate customer customization and management.   Application YH1200 haze meter is widely used in glass processing, plastic processing, film processing, screen processing, packaging industry, liquid pharmaceutical analysis and other aspects.   Specification Product Model GBPI Haze Meter Optical Geometry Transmittance:0/D (Parallel light illumination, diffuse viewing); Conform to the standards: ASTM D1003/1044,ISO 13468,ISO 14782,GB/T 2410,JJF 1303-2011,CIE 15.2,JIS K7105,JIS K7361,JIS K 7136 Characteristic The instrument can easily achieve ASTM D1003 non-compensation method, full light transmittance,haze test. Open measuring area for vertical and horizontal testing. In glass processing, plastic processing, film, screen processing, packaging and other industries are widely used in transmittance,haze detection. Integrating Sphere Size Φ154mm Light Source 400nm to 700nm, combined LED light Spectrophotometric Mode / Sensor The PD array detector satisfies CIE V(λ)2 degree visual response Wavelength Range / Wavelength Interval / Semiband Width / Measurement range 0~100% Measuring Aperture Φ20mm/Φ15mm/Φ8mm/Φ4mm(Select a single aperture) Sample Size Thickness <170mm Color Space / Color Difference Formula / Other Colorimetric Index Haze(ASTM D1003/1044,ISO13468),Transmittance T(ISO),Transmittance T(ASTM) Observer Angle 2° Illuminant D65,A,C Displayed Data PASS/FAIL Result Measuring Time About1.5s Resolution 0.01unit Repeatability Φ20mm,within 0.05 (After preheating and calibration of the instrument, standard deviation values of standard haze tablets with a test haze of about 30 for 30 times were taken at intervals of 5s.) Inter-instrument Error Φ20mm,with 0.4 (After the instrument is preheated and calibrated, the standard deviation between the standard haze tablet and the reference value is tested at an interval of 5s.) Dimension L*W*H=290X211X511mm Weight About7.6kg Power AC 24V, 3A Power adapter power supply Illuminant Life Span 5 years, more than 3 million times measurements Display 7-inch TFT color LCD, Capacitive Touch Screen Data Port USB, Print serial port Data Storage Standard 1000 pcs,sample 20000 pcs Language Simplified Chinese,Traditional Chinese,English Operating Environment 0~40℃(32~104°F) Storage Environment -20~50℃(-4~122°F) Standard Accessory Power Adapter, User Guide,Quality Management Software (download from the official website),USB cable,0% calibration box, measuring aperture. Optional Accessory Micro-printer,Test fixture, standard haze sheet, foot switch Note: The specifications are subject to change without notice.      
Portable Digital Gloss Meter KGZ 1C Intelligent Gloss Tester
  Application used to detect the gloss of plastic film, paper, ink, adhesive, etc. Multi-point measurement and data processing can be performed on the sample, and parameters such as average value, standard deviation and coefficient of variation can be printed directly. The machine has high precision and good stability, and can measure the glossiness of flat products such as paint, paper, plastic, ceramic, stone and metal.   Feature  Full-function intelligent design, light touch key operation.  Automatic measurement and manual measurement function.  For single point or no more than 10 points measurement, calculate the average value, root mean square, coefficient of variation and print out the result.   Standards  Angle International Standard Chines Standard Application 20 ISO-2813 ISO8254 GB9754 GB8807 Coating Plastic 20 TAPPI-T653 ASTM-D1834 GB8941.1 Paper 45 ISO-2767 GB8941.2 Metal compound paper 45 ASTM-C346 ASTM-D2457 GB8807 Ceramics、Plastic 45 JIS-E8741   Coating 60 ISO-2813 ASTM-D2457 GB9754 GB9966 GB8807 Coating Stone Plastic 75 TAPPI-T480 GB9841.3 Paper 85 ISO-2813 GB9754 Coating   Specifications Item Specification Test range 0-199.9 Gloss units Precision ±1.0 Gloss units Stability Not more than 0.5 gloss unit / every 30 minutes Repeatability Not more than 0.5 gloss unit Measuring probe size 180mm×100mm×50mm Power 25w/ 220vAC,50HZ      
Tensile Tester GBL-L2 Plastic Film Tensile Tester
The GBL-L2 popular single-column electronic tensile tester is suitable for tensile, peeling, heat-sealing, tearing and other mechanical performance tests of various metal and non-metal materials. It meets the requirements of the national technical supervision department for test technology. It is widely used in plastic film, food, and pharmaceutical manufacturers to test products quality control and testing institutions, scientific research and teaching experiments in university.
Vacuum Freeze Dryer Vacuum Freeze Dryer GB-LGJ-200F
Introduction Factory use vacuum freeze dryer is suitable for drying product such as food, drug products, biological products, Chinese medicine and more. It is to dry product at low temperature to preserve, stabilize, store and increase the life of products.. Freeze vacuum drying is a new type of box structure introduced by the vacuum freeze dryer that combines the refrigeration system, vacuum system, heat transfer oil heating system, and moisture removal system. It uses the space for storing materials in the box to dry. Main Technical Parameters   Item GB-LGJ-200F Drying chamber Freeze-drying area 2.25m2 Layers of shelf 5+1 Temperature scope of shelf -50℃-+70℃ (no-load) Shelf temperature error ±1℃ (in balance) Shelf spacing 70mm Size of shelf 500mm*900mm Condenser Min. Temperature of condenser ≤-70℃ (no-load) Water-capture capability >30Kg Liquid material 22L(thickness 10mm) Defrosting Electric defrosting Final Vacuum degree ≤ 5Pa Style of cooling Fan cooling Main functions Manual + Auto Control Mode, Sensor calibration, Intelligent temperature control, Freeze drying termination reminding and other functions are available.               Technical parameters □ Main configuration   Shelf effective area 2.25 m2 □ Specification   Shelf size 500mm × 900mm   Shelf numbers 5+1(Radiation layer) Top shelf as temperature compensating plate   Material number plate 10 pcs   Shelf spacing 70 mm   Shelf temperature range -50℃~+70℃ (no-load)   Min. condenser temp. ≤ -70℃  (no-load)   System final vacuum degree ≤ 5Pa □ Basic configuration    Installation Power 13.5KW     ★ This is installed power, not operating power. □ Shape and other parts   Dimension(mm): About 1200x2100x1700mm, L*W*H   Weight(Kg):  About 1200   Noise ≤ 80dB   Electrical system Ground protection   Design, production, installation standards According to GMP, GB/T522 6.1-1996   Whole machine test Test, verify data, methods, and equipment support □ Drying chamber components   Shape Rectangular   Roughness of inner wall Ra ≤ 0.6μm   Opening direction Clockwise or anticlockwise (overlooking ,user confirm)   Chamber material AISI 304  stainless steel ◆  Door  material ACRYLIC   Working temperature ≥ 70℃   Thermal insulation material Polyurethane foam □ Shelf components ◆ Shelf material AISI 304  Top and bottom plate thickness 5mm ◆ Shelf structure AISI 304 stainless steel (Patent No. :ZL201020237059.X)   Roughness of shelf Ra ≤ 0.6 μm   Flatness ≤ ±0.5mm / m   Effective shelf size 500mm×900 mm   Amount of shelf 5+1     Effective area of shelf 2.25m2 ◆ Shelf spacing  70 mm   Temperature decreasing rate +20℃ down to -40℃/ within 60 min, (no-load, entrance of silicon oil )   Temperature elevating rate -40℃ up to +20℃/ within 60 min, (no-load, entrance of silicon oil ) ◆ Shelf lowest temperature ≤ -50℃      (no-load, entrance of silicon oil )   Shelf highest temperature ≥ +70℃    (no-load, entrance of silicon oil )   Shelf temperature error ≤ ±1℃ ≤ ±1℃ ( in balance ) □ Condenser components   Condenser Shape Vertical type, cylindrical Compact structure, better water capture ,easy to clean and defrosting ◆ Condenser material AISI 304   Condenser water capture ≥ 30Kg   Condenser temp. Decreasing +20℃--40℃, within 30 minutes ◆   Condenser Min. temp. ≤ -70℃   Defrosting Electrochemical cream ◆ Thermal insulation material Polyurethane foam □ Refrigeration system   Refrigerator France original imported TECUMSEH full closure compressor ◆ Refrigerant Environmentally friendly refrigerant   Refrigerator number 2 sets   Shelf refrigeration 1 sets (shelf refrigeration at same time, indirect refrigeration)   Condenser refrigeration 1 set (shelf refrigeration at same time, direct refrigeration) ★ World famous devices are used to make sure correct, stable, safe and reliable.   High pressure protection device When system’s air discharge pressure exceeds allowed pressure, machine automatically stops working, to avoid an accident.   expansion valve DANFOSS(Denmark)   Top cover valve Castel(Italy)   solenoid valve DANFOSS(Denmark)   Oil separator ZOER   High pressure controller DANFOSS(Denmark)   Disacidify filter DANFOSS(Denmark)   Pressure meter LR/REFCO LR/REFCO(Germany/Swiss) oil submerge  pressure meter   Water cooling condenser Well-known brand □ Vacuum system ◆ Double stage rotary vane pump Tan's Vacuum Pump   Quantity 1 set ◆ Vacuum gauge Reborn   Chamber pumping rate Atmosphere→10 Pa ≤30 minutes(in dry condition)   System Maximum vacuum ≤ 5Pa   System leaking rate ≤ 10 Pa·l / sec □ Liquid circulation system ◆   Liquid low viscosity silicon oil ( 25℃, 5cst ) National qualified product   Liquid tubing material AISI 304, welding, heat  keeping ◆ Circulation pump ★GRUNDFOS, original imports, web rotor canned pump From Denmark brand, world famous brand   Circulation pump quantity 1 set   Heating rate 4kW   Heating control style Solid-state relay ◆ Stainless steel plate heat exchanger Well-known brands   Temperature sensor PT-100 platinum resistance □  Control system ◆ Control style Automatic and manual control ◆ Control system FD-PILOT   Control board SH-HPSC-II   Touch screen MCGS   Intermediate relay CHINT   AC contactor CHINT   Air circuit-breaker CHINT   Wiring terminals: Well-known brands □ Safety protection   Whole machine protection All safety conditions are ready for whole machine, machine can start running.   Operation protection Electrical system have logic interlock, control and protection function   Vacuum pressure Available   Heating system Available   Power cut and supply With safety protection measure   Products protection during sublimation process Heat cutting if vacuum lack   Condenser protection when vacuum pump start Interlock □ Whole machine design   Power 3Ph+N+PE, 380V   Installed power 13.5 KW (this is installed power, not running power)   Whole machine structure Integrated structure (easy for transport and placement)   Whole machine size About  1200x2100x1700mm, L*W*H   Whole machine weight (kg) About 1200   Time of warranty: One year after site acceptance.  
Professional GB-KF30010  Medical ProtectionTextile Mask Particulate Filtration Efficiency Tester supplier GB-KF30010 Medical ProtectionTextile Mask Particulate Filtration Efficiency Tester
Application It is to test the filtering efficiency of particulate protective masks and medical masks and to determine the resistance of ordinary fabrics and medical protective masks to the constant flow of airflow.
Glass Bottle Internal Pressure Resistance Tester GBPI Glass Bottle Internal Pressure Resistance Tester
Glass Bottle Internal Pressure Tester is suitable for the internal pressure test of all kinds of beer bottles, wine bottles, beverage bottles, infusion bottles, antibiotic vials, etc. instrument meets the requirements of the holding pressure test and explosive pressure test of any size of bottles. The internal pressure test machine for glass bottles is used by breweries, glass bottle manufacturers, testing agencies and pharmaceutical manufacturers
Heat Shrink Tester Heat Shrink Tester ASTM D2732 GBK-1
GBK-1 Heat Shrinkage Tester is for testing the heating shrinkage of packaging films submerged in liquid in different temperatures.
Atmosphere Refrigerator AUTO GQ100 Modified Atmosphere Refrigerator
  The AUTO GQ-100 Modified Atmosphere Refrigerator is meticulously engineered for storage and preservation tests of diverse fruits, vegetables, flowers, seedlings, and more. By harnessing microelectronics technology, it automatically regulates the concentrations of oxygen, nitrogen, carbon dioxide, and ethylene inside the refrigerator, along with temperature and humidity conditions, to achieve outstanding preservation effects. It is an essential and perfect equipment for microbiology, environmental protection, food production, universities, research institutions, and other relevant organizations.   Technical Parameters Project Technical Parameter Gas Measurement Range O₂: 0%–30%; CO₂: 0%–20%; C₂H₄: 0–220 ppm; Remaining gas: N₂ Gas Testing Accuracy O₂: 0.01%; CO₂: 0.01%; C₂H₄: 0.1 ppm Gas Purity Requirement Purity of O₂, CO₂, N₂, and C₂H₄ ≥ 99.9% Gas Flow Control O₂: 0–500 mL/min; CO₂: 0–500 mL/min; N₂: 0–500 mL/min Temperature Control Range -5°C–45°C Chamber Temperature Control Accuracy ±0.5°C Chamber Humidity Range Normal–95% RH Humidity Fluctuation Range ±3% RH Cooling Capacity 1 HP Chamber Humidifier Power 50 W Chamber Lighting System Power 10 W Material Colored steel plate Dimensions 889 mm × 1285 mm × 1750 mm Total Machine Power 1 KW Number/Volume of Test Chambers 1 chamber/100 L Power Supply AC 220V   Application   Fruit and vegetable storage and preservation It is suitable for the storage and preservation test of various domestic and imported fruits and vegetables.   Storage and preservation of meat and seafood It is suitable for storage and preservation test of various pork, beef, mutton and other meat and seafood products such as fish, shrimp, crab, etc.   Baked food storage and preservation It is suitable for the storage and preservation test of various bakery products such as bread, cakes and biscuits.   Storage and preservation of flowers and seedlings It is suitable for the storage and preservation test of various roses, lilies, phalaenopsis and other flowers and seedlings.   Product features Three test chambers work independently; Each chamber has its own humidity, flow and concentration of various gases, ethylene removal devices, lighting systems, sterilization systems, and drainage systems.  Built-in microcomputer system, automatic control, and automatic processing of data. Manually switch the cavity to display the temperature and humidity of each cavity, as well as the concentration of oxygen, nitrogen, carbon dioxide, ethylene, and so on.   24 inch 100,000 real color touch screen, can set the parameters of each cavity and control operations respectively; Detailed data and work status are displayed in real time.  Built-in ozone sterilization, manual button sterilization, can set the sterilization time.  Built-in ethylene catalytic removal device and gas displacement pump control ethylene concentration, fast degassing speed.  Imported high-precision sensors to detect various gas concentrations and ethylene concentrations. The sterilization system adopts ozone sterilization, the manual button for sterilization, automatic control of sterilization time, and automatic stop when the set time is reached. Temperature control: using heating wire heating, scroll compressor cooling, stable performance, low noise; PID algorithm with solid state relay control, no hard mechanical contacts, long service life, average temperature heating, constant temperature. The temperature control of each chamber adopts unified control, and the temperature of the three chambers is set manually. Humidity control: high-frequency atomization humidification, the humidification range is large, long-term humidification does not heat, does not affect the cavity temperature; Each chamber humidification system operates independently, automatically humidifies and maintains humidity after setting the humidity. The inner wall of each cavity is made of stainless steel, the special double-layer glass door, and the shell is made of special color steel plate.  Transparent windows, drainage system anti-condensation, built-in lighting, and self-entry box design.
  • Facebook
  • Linkedin
  • Youtube
  • Twitter

Copyright @ 2026 Guangzhou Biaoji Packaging Equipment Co.,Ltd. All Rights Reserved.

Chat now

Inquiry Now

Home

Products

NEWS

contact