ZF800B Automatic Evaporated Residues Tester

Automatic Evaporated Residues Tester is pplicable to tableware, food containers, packaging films, bags, cap sealing rubber pad, painted coating for inner wall of cans or tins, plant fiber container and so on


  • Brand:

    GBPI
  • Item NO.:

    ZF800B
  • Payment:

    100% T/T In Advance
  • Product Origin:

    Guangzhou China
  • Shipping Port:

    Huangpu
  • Lead Time:

    20-30 days
Inquiry now
Product Detail

Automatic Evaporated Residues Tester

Evaporated Residues Tester


Working principle

Soak test sample in specified liquid; wash and evaporate evaporating dish dry, and put it into the machine chamber to dry it until its weight is constant; take an amount of the liquid and hold it in evaporating dish,  evaporate the dish dry in water bath device; then put evaporating dish in machine chamber to dry in high temperature, and weigh the dish; then dry again, and weigh again, repeat this process until the weight is constant; the weight minus the weight of evaporating dish itself is the value of Evaporated Residues.


Standards

GB/T 5009.60-2003、GB/T 5009.64-2003、GB/T 5009.68-2003、GB/T 5009.69-2008、GB/T 5009.203-2003、GB/T 9740-2008


Features

Advanced Configuration and Technology

1) Carry cutting-edge ARM controlling system, and configured with a 7-inch color touch screen for setting parameters, display curves and report. Realtime displays the sample weights, residue rate, temperature and humidity.

2) With built-in water bath evaporating system and the water bath kettle adds water automatically.

3) Heating system adopts panel electromagnetic temperature controlling device. Program stepping temperature controlling system controls the temperature precisely, precluding over-heating.

4) Only need to manually put evaporating dish with liquid sample in machine test chamber; evaporating, drying, weighing, repeating process, constant weight judgment, and calculation are all automatically done by computer program.

5) Automatically saves test report with convenient and various checking function, easy to manage.

6) Supports win 10 operating system.


Safe

Really heated by water bath—prevent accident caused by air heating.

1) With solvent recycling system, preventing discharge of harmful solvents and caring the health of operator.

2) Airproof design prevents leakage in the evaporating process.

Fully Automatic and Easy Operation

1) Fully automatic operation, the entire evaporating procedure can work without manual operation.

2) Professional test report that can be exported in Office or PDF formats easily.

High Efficiency.

3) Eight work stations, each with independent test data; can test 8 samples at the same time.


Specifications

Test range

0~80g (residue weight)

Test precision

±0.2mg

Resolution

0.1mg

Temperature range

Room temperature~130℃

Temperature precision

±0.2℃

Heated air circulation speed

0.2 m/s

Test sample volume

0~200mL

Test sample number

1~9 pcs (each sample is independent)

Instrument size

937 mm × 660 mm× 830 mm

Power supply

AC 220V, 50HZ

Power

4000W



Send A Message

Leave us a message, we will get back to you ASAP.

Related Products
color measurement device Portable Handheld Spectrophotometers for Plastic Electronic Painting Coating Ink Textile etc Colorimeter Color Difference Meter Tester
Application It is used for accurate color analysis and transmission; it is used for precision color measurement and quality control in plastic electronics, paint ink, textile and garment printing, printing, ceramics, etc.; it can be used for fluorescence sample measurement.
Temperature & Humidity Test Chamber Temperature & Humidity Test Chamber OTH-150DJ
OTH-150DJ is used to test the performance of materials in various environments and test the heat resistance, cold resistance, dry resistance and humidity resistance of various materials. It is suitable for quality testing of products such as electronics, electrical appliances, mobile phones, communications, instruments, vehicles, plastic products, metals, food, chemicals, building materials, medical care, and aerospace.  
 Disk Stripping Tester Gx-B2 Disk Stripping Tester
To test the ink layer bonding strength of printed (intaglio) plastic film, composite film, cellophane and so on; test the layer bonding status formed by vacuum coating, surface coating and composite technology etc. It meets the GB/T 7707-2008 standard The intaglio prints for decorating.
Adhesive Tape Roller Pressing Machine Plastic Film Adhesive Tape Rolling Pressing Machine
The Adhesive Tape Roller GX-Y2 is suitable for plastic film and cellophane decorative prints (including composite film prints) produced by gravure printing process. It is also used to test the adhesion state of the surface layer formed by vacuum coating, surface coating, compounding and other related processes.
 Face Mask Particulate Filtration Efficiency Tester Face Mask Particulate Filtration Efficiency Tester
GBPI offers mask testing machines for surgical face masks, N95 masks, Melt-blown fabric. BFE Tester, PFE Tester, N95 Tester, Melt-blown fabric Tester
Falling ball impact tester Falling ball impact tester GQ-D1
1. Product introduction The GQ-D1 falling ball impact tester is mainly suitable for testing the impact strength of steel balls for food packaging rigid tablets, solid pharmaceutical rigid tablets and plastic bottle cap products. During the test, put the test product on the test bench of the falling ball impact tester, make the steel ball of the specified weight fall freely on the product from the specified height, impact the product, and then check whether the appearance of the product is damaged and all aspects of performance.   2.Product features u The host is equipped with a color touch screen, which is convenient for users to perform test operations. u The novel mechanical model and the humanized design of the operation interface make the operation of the instrument simple and convenient; u Traditional electromagnets will generate high temperature when they generate magnetism, and there will be residual magnetism after power failure, which will affect the accuracy of the experiment. This instrument adopts the principle of energization and repulsion, which can automatically release, avoiding residual magnetism and high temperature, and ensuring the accuracy of the experiment. u The test process is intelligent, which greatly improves work efficiency; u The sample is pneumatically clamped and released, which reduces the error and test time; u Built-in printer, which can print test reports. u The instrument can query the data and the results of each experiment. u The test results are accurate.     3.Standard GB/T 15267-1994、GB/T 17876-2010、YBB0021-2005、YBB00202005   4.Technical Parameter   Item Technical Parameters Impact Height 0 - 900 mm Steel Ball Diameters 23 mm (approximately 50 g), 25 mm (approximately 60 g), 28.6 mm (approximately 100 g), 38.1 mm (approximately 225 g) Specimen Clamping Range 120mm*85mm Specimen Size 150 mm (Length) × 50 mm (Width) Overall Dimensions 325 mm × 550 mm × 1341 mm Power 75 W Weight 30kg Power Supply AC 220 V, 50 Hz  
PFE tester ASTM F2299/Mask Particle Filtration Efficiency (PFE) Tester
Face Mask Particulate Filtration Efficiency is to test the filtering efficiency of particulate protective masks . This instrument conforms to ASTM F2299, NIOSH-42CFR-84, GB 2626-2019, YY 0469-2011 and GB/T32610-2016 standard. GBPI offers mask testing machines for surgical face masks, N95 masks, Melt-blown fabric. BFE Tester, PFE Tester, N95 Tester, Melt-blown fabric Tester.
Cap Torque Analyzers Torque Testing Equipment HP-200
Torque tester HP-200 is a testing instrument for bottle cap locking and opening based on ASTM and GB standard requirements and market demand developed and manufactured by GBPI R&D team. For bottle packaging products, nozzle packaging products and tube packaging products, the size of the cap opening torque is one of the key control parameters, which has a great impact on the intermediate transportation and final consumption of the product.It is suitable for measuring the size of the locking and opening torque of bottle products, and is an indispensable test equipment in the production process.
Water Vapor Permeability Analyzer Water Vapor Permeability Analyzer AUTO W809
Water Vapor Permeability Analyzer -AUTO W809 is designed and manufactured in accordance with ASTM E96, GB/T 1037 standards, and provides a wide range of high-efficiency water vapor transmission rate testing for low, medium and high water vapor barrier materials with the  principle of Gravimetric Method.
Salt Spray Tester Salt spray test chamber GB-OSH-60
  1. FunFunction Salt spray test chamber is used for the quality inspection and corrosion resistance test of a variety of materials, including metal plating, metal, electronic components, chemical coatings, paint, automobiles, motorcycles, metal ware, screws, springs, magnetic materials, organic and inorganic coating, anodizing, anti-rust oil industry etc. after the surface treatment.   1. ecGTechnical parameters   1. MODEL GB-OSH-60 2. Temperature inside chamber 35℃±1℃/ 50℃±1℃ 3. Temperature of pressure barrel 47℃±1℃/ 63℃±1℃  4. Inner size W600 x H400 x D450mm   5. External size W1080 x H1080 x D650mm 6. Temperature Uniformity ≤±2℃ 7. Uniformity Fluctuation ≤±0.5℃ 8. Salt fog settlement 1~2ml/h.80cm2 9. Compressed air pressure 1.00±0.01kgf/cm² 10. Spray mode Continuous or intermittent spray optional 11. Power supply AC  220V   50Hz   1.5KW a)  Temp. range: RT+10℃ ~ 55℃ (temperature up to 50C, thickening PVC or PP material is recommended ) b) Humid. range: ≥93%R.H c) Controller time shown: 9.9s~9990hrs d) Timer: 0~9999hrs. e) Testing method: Neutral salt spray test (NSS test), acetic acid salt spray test (AASS test), salt spray test (SS test), copper accelerated acetic acid salt spray test method for salt spray test (CASS test) and so on; (For CASS test, we recommend the PP material chamber with high temperature resistance) f) Specimen holder: It can meet the tilt test at 15 ℃ ~ 30 ℃ (two layers); g) Air compressor: V-0.013/12.5(Customer provided); discharge pressure:1.25M; flow amount: 0.13m3/min   1. MMMaterial of machine body a) Salt spray chamber adopts the quality PVC reinforced hard plastic plate, the surface is smooth and anti-aging, anti-corrosion; b) Without any FRP material produced on the surface because of discoloration fibrosis. Plastic structure of the chamber is better to meet strong acid salt spray test under long-term without any damage. c) Cover is imported transparent impact-resistant plate which is convenient to test specimen when test, that can cover and the box with a water seal to prevent leakage of salt spray.   2. AccAccording to CSN, JIS, ASTM standards, can be set to constant temperature control: (a) Brine spray test: NSS (neutral); · Temp. inside chamber: 35 ℃ ± 1 ℃ · Pressure air bucket: 47 ℃ ± 1 ℃ (b) Corrosion resistance test: CASS (copper acceleration), AASS (acid) · Temp. inside chamber: 50 ° C ± 1 ° C · Pressure air bucket: 63 ℃ ± 1 ℃   3. Watwatering system. It adopts the auto watering system, supply water when lack of water. 4. HeaHeating system Test temperature inside the cabinets is heated humidification water jacket, the heater adopts advanced titanium protective tube, built-in nickel-chromium alloy infrared heater core. Heating up fast, uniform temperature distribution; and saves about one half of the power compared to FRP tank jacketed heating. 5. ExeExecutive standard GB/T 2423.17 Basic test procedures for electric and electronic products Ka"- salt spray test methods; GB/T 10125 Corrosion tests in artificial atmospheres – salt spray tests; ASTM B368 Test Method for Copper-Accelerated Acetic Acid-Salt Spray (Fog) Testing (CASS Test); JIS Z2371-2000 Methods of salt spray testing etc. ISO 9227 Corrosion tests in artificial atmospheres (Note: 2 collection device is required, bigger models than ZH-SH-90 (270L) is required; In some versions, it specifies over 400liters is necessary)  ASTM B117-18 Standard Practice for Operating Salt Spray (Fog) Apparatus (Note: 2 collection device is required, bigger models than ZH-SH-90 is required )  
Vacuum Decay Leak Detection Tester Dual Pressure Methods Vacuum Decay Leak Detection Tester AUTO GBM-L2
Introduction AUTO GBM-L2 Dual-Pressure Methods Vacuum Decay Leak Detection Tester adopts the test principle of vacuum decay method/pressure decay to detect micro-leakage of finished packaging. It can be applied to packaging systems composed of vials, ampoules, Leakage detection of pre-filled needles, eye drop bottles, HDPE bottles, infusion bottles/bags and other pharmaceutical packaging, food packaging, and chemical industry packaging.   Test principle The host is connected to a sealed test chamber customized according to the sample. When performing the vacuum decay method test, the instrument evacuates the test chamber, and a pressure difference is formed inside and outside the sample. Under the action of the pressure, the gas/liquid in the sample enters the test chamber through the leak hole. The main engine uses the absolute pressure sensor and the differential pressure sensor to monitor the pressure change in the chamber to judge whether the sample leaks. When performing the pressure decay method test, the instrument fills the test chamber with a predetermined air pressure, and the gas in the test chamber enters the sample through the leak hole. The host uses absolute pressure sensors and differential pressure sensors to monitor the pressure changes in the chamber to determine whether the sample is leaking.   Standard ASTM F2338-2009(2013),  YY-T 0681.18-2020,  USP<1207.2>, ASTM F2095   Specification Item Parameters Absolute Pressure Testing Range (0 - 300) kPa Differential Pressure Testing Range (-2 - 2) kPa Detection Sensitivity 1 - 3 μm Balancing/Testing Time 1 - 3600 s Vacuum Purge Time 1 - 3600 s Set Flow Rate 0 - 3 mL/min Testing System Dual Sensor Technology/Dual Cycle Testing Testing Chamber Customized according to the sample Applicable Products Vials, Ampoules, Prefilled Syringes, Infusion Bottles/Bags, etc. Detection Principle Vacuum Decay Method/Pressure Decay Method Dimensions of the Main Unit 495 mm455 mm280 mm Ambient Temperature 20℃ - 25℃ Relative Humidity 40% - 60% Working Power Supply AC 220V, 50HZ   Features u Dual-Pressure Methods, to help solve testing difficulties The double combination of vacuum decay method and pressure decay method solves the problem of easy misjudgment and false negative for freeze-dried powder injections containing vacuum in the bottle using a single vacuum decay method. Based on dual-sensor and dual-circulation system technology, high-quality absolute pressure sensor and differential pressure sensor, with an accuracy of 0.1% FS, can effectively detect large and small leaks, accurately calculate the leak hole diameter, and give a pass or fail judgment.   The instrument has low sensitivity and good test repeatability For rigid samples, the detection sensitivity is as low as 1 μm, and the test repeatability is as low as 0.8%. The instrument has stable performance, low noise and good repeatability. u Imported brand accessories, excellent performance Imported brand vacuum pump, pumping rate up to 3 L/s, noise as low as 50 DB, high ultimate vacuum, convenient oil level detection and replacement. The imported gas mass flow controller can simulate micro-leaks arbitrarily, with a resolution of 0.001 mL/min, which provides a reliable guarantee for the method verification of instrument sensitivity. u Large size touch screen, intelligent operation Color 7-inch touch screen, clear view, sensitive touch, easy to operate. Equipped with a micro-printer, USB data interface, and supports PC software measurement and control operation. The test software is designed according to the GMP appendix "Computerized System". It has an audit trail function and multi-level authority settings for users, which can meet the needs of the pharmaceutical industry for data traceability. u Personalized customization to meet the needs of different samples For different test samples, it supports customization of suitable test chambers to meet the needs of different tests. For the same type of samples, it supports customized nesting mode, which can realize the sharing of a test chamber for samples of various specifications.   Application       Freeze-dried powder injection Injection Prefill needle       Eye drops Plastic Ampoule BFS Infusion bags   Factory configuration Standard Host machine, vacuum pump, test chamber and 3 sets of yin and yang control (customized as required), 11-inch touch panel, professional software (GMP) Optional Imported gas flow meters, air compressors, printers, calibration certificates  
Biodegradation tester for plastic in soil AUTO GBDA-180 Compost Degradation plastics test equipment
AUTO GBDA-180 The Compost Degradation Tester is based on the gravimetric method for measuring carbon dioxide emissions. It is a professional use of small reactors to determine the final biodegradability of test materials. It is suitable for the biodegradability analysis of degradable plastics and bio-based materials such as lunch box garbage, waste ground film, plastics containing plasticizers and pigment additives, etc.
  • Facebook
  • Linkedin
  • Youtube
  • Twitter

Copyright @ 2026 Guangzhou Biaoji Packaging Equipment Co.,Ltd. All Rights Reserved.

Chat now

Inquiry Now

Home

Products

NEWS

contact