packaging testing equipment Water Vapor Permeation Tester
Products
Home /

Breathability Series

/Air Permeability Analyzer for Textile- N900

Air Permeability Analyzer for Textile- N900

N900 Air Permeability Analyzer to test the air permeability of many textile, including technical fabric, non-woven and breathable textile products.

 

  • Brand:

    GBPI
  • Item NO.:

    N900
  • Payment:

    T/T, LC
  • Product Origin:

    Guangzhou China
  • Shipping Port:

    Huangpu
  • Lead Time:

    20-30 days
Inquiry now Download
Product Detail

 

1. Product Introduction

N900 Air permeability analyzer, a blend ofmechanism, electron and software, is high precision experiment-usage testing instrument developed by GB/T5453-1997  Textile--Determination of the permeability of fabrics of air.

Itis applied to test the air permeability of many textile, including technical fabric, non-woven and breathable textile products.

Key components:imported pressure sensor, turbofan, air cylinder, motor

 

2. Working Principle

Air permeability refers to the performance of air pass through the fabric. Indicate it by the rate of airflow vertically penetrating the test sample in a certain test area, pressure drop and time.

Keeping a pressure difference, test the airflow vertically penetrating the test area of sample in a certain period of time, so as to calculate the air transmission rate. The airflow rate can be calculated directly, or calculated by testing pressure differences between two sides of flow pore.

 

3. Standard

ISO 4638-1984, ASTM D737-2004(2016), GB/T 5453-1997, ISO 9237-1995, GOST ISO 9237-2013, GB/T 10655-2003, QB/T 2799-2006

 

4. Technical Specifications

 

Item

Specifications

Pressure

differential 

measurement range

 

 

14000Papressure drop can be adjusted

Test range

140000mm/s

Test error

≤±2%

Sample size

150mm×150mm

Test area

5cm220 cm250 cm2100 cm2

Sample thickness

10mm

 

5.Instrument Features

1) Cylinder control and fix the sample automatically, quick test.

2) Pressure adjustable; auto measure, auto calculate results.

3) Mainframe configures color touch screen, without external computer, can  observe the permeability rate of the sample in real-time.

4) Can test multiple sets of data continuously; can query, delete a group or groups of experimental results, print reports.

5) Professional software, simple interface, easy to operate, display test data (air permeability, variation coefficient and other parameters) in real time, support different unit conversion. ( Test unit: mm/s, l/(dm^2.min), l/(m^2.s), m^3/(m^2.min), m^3/(m^2.h), cfm, cm^3/(cm^2.h), ml/s, ml/min, l/s, l/min)

6) Generate standard test report automatically, details contain sample name, specifications, serial number, the direction of the airflow through the fabric, test area and the pressure drop of the experiment, standard, test dates, and test results (air permeability rate, variation coefficient, 95% confidence interval).

Send A Message

Leave us a message, we will get back to you ASAP.

Related Products
Professional Carbon Paper Air Permeability Rate Tester supplier Carbon Paper Air Permeability Rate Tester
Product Brief The N600C Carbon Paper Air Permeability Rate Tester is designed and developed in accordance with GB/T 20042.7-2014. Adopting the differential pressure method as its testing principle, it is professionally used for measuring the air permeability rate of various types of carbon paper for proton exchange membrane fuel cells (PEMFC). Testing Principle Based on the differential pressure method, the sample is placed between two fixtures, forming a constant differential pressure on both sides of the sample. Driven by the differential pressure, gas flows from the high-pressure side through the sample to the low-pressure side. The air permeability rate of the carbon paper is calculated based on the transmission flow rate, sample thickness, test area, and test differential pressure. Executed Standards GB/T 20042.7-2014 Technical Parameters Item Technical Parameters Test Range 0~200,000 mL·mm/(cm²·h·mmHg)0~14,701 mL·mm/(cm²·hr·mmAq) Resolution 0.1 mL·mm/(cm²·h·mmHg)0.1 mL·mm/(cm²·hr·mmAq) Pressure Range 0~500 Pa (other ranges available upon request) Pressure Resolution 0.1 Pa Pressure Accuracy 0.1% FS (Full Scale) Flow Range 0~50 L/min (other ranges available upon request) Flow Resolution 1 mL/min Flow Accuracy 1% FS (Full Scale) Test Area 16 cm² Instrument Dimensions 410 mm×295 mm×365 mm Power 100 W Power Supply 110~250 VAC, 50~60 Hz Product Features • The instrument's differential pressure is adjustable within the range of 0~500 Pa, with an accuracy of 0.1% FS, fully meeting the test pressure requirements of different samples;• The test range can be customized according to different sample requirements;• Arbitrary pressure adjustment, fully automatic operation, and automatic measurement and calculation of results;• Equipped with a color touch screen, no external computer required;• Built-in micro-printer for real-time printing of test reports;• The upper computer software is designed in accordance with the new GMP Appendix "Computerized Systems", supporting functions such as hierarchical permission management, audit trail, and electronic signature (optional).  
Professional Battery Separator Air Permeability Tester supplier Battery Separator Air Permeability Tester
Product Brief The N600E Battery Separator Air Permeability Tester is designed and developed in accordance with standards such as GB/T 36363-2018. Adopting the differential pressure method as its testing principle, it is professionally used for testing the air permeability of battery separators, breathable films, and related polymer materials. Testing Principle In an environment with controlled temperature, humidity, and normal pressure, the tester measures the time required for 100 mL of air to pass through a 6.45 cm² separator under an applied pressure of 1.21 kPa. Executed Standards GB/T 36363-2018, ISO 5636-5:2003, TAPPI T460 Technical Parameters Item Technical Parameters Test Range 60~12000 sec/100mL Resolution 0.1 sec/100mL Pressure Range 0~5 kPa Pressure Resolution 0.001 kPa Test Area 6.45 cm² Sample Size >50 mm×50 mm Instrument Dimensions 450 mm×400 mm×300 mm Power 100 W Power Supply 110~250 VAC, 50~60 Hz Product Features • The instrument's differential pressure is adjustable within the range of 0~5 kPa, with a precision of 0.001 kPa, fully meeting the test pressure requirements of different methods;• Supports multi-unit display (s/100mL and μm/(Pa·s));• The test range can be customized according to different sample requirements;• Excellent airtightness;• Arbitrary pressure adjustment, fully automatic operation, and automatic measurement and calculation of results;• Equipped with a color touch screen, no external computer required, enabling real-time observation of sample air permeability;• Built-in micro-printer for real-time printing of test reports;• The upper computer software is designed in accordance with the new GMP Appendix "Computerized Systems", supporting functions such as hierarchical permission management, audit trail, and electronic signature (optional).
Professional Paper & Paperboard Air Permeability Tester supplier Paper & Paperboard Air Permeability Tester
Product Brief The N600P Paper & Paperboard Air Permeability Tester is custom-developed to align with standards like GB/T 458-2008 and ISO 5636. It adopts the differential pressure method as its core testing principle, and innovatively integrates three industry-common testing approaches (Gurley, Schopper, and Bendtsen) into a single device.   This tester is applicable to air permeability detection of various paper and paperboard materials, and can measure key indicators including: material air permeability, air resistance, gas transmission rate, and total gas transmission volume. Testing Principle Gurley Method   Under a constant differential pressure of 1.23 kPa, measure the time required for 100 mL of gas to pass through the sample. Schopper Method   Select a suitable test duration under a constant differential pressure (1.00 kPa±0.01 kPa or 2.50±0.01 kPa), and calculate the gas flow rate through the sample by measuring the gas volume. Bendtsen Method   After clamping the sample for 5 seconds under a constant differential pressure of 1.47 kPa, test the gas flow rate through the surface of the sample. Executed Standards GB/T 458-2008, SJ/T 10171-2016, ISO 5636-5:2003, ISO 5636-2:1984, ISO 5636-3:2013, TAPPI T460 Technical Parameters   Item Technical Parameters Test Range 0.1~10 μm/(Pa·s) Resolution 0.001 μm/(Pa·s) Differential Pressure Range 0~5 kPa Pressure Resolution 0.001 kPa Test Area 6.42 cm² or 10.0 cm² Sample Size >50 mm×50 mm Instrument Dimensions (L×W×H) 450 mm×400 mm×300 mm Power 100 W Power Supply 110~250 VAC, 50~60 Hz
migration testing in food packaging Full-Automatic Overall Migration Tester -AUTO ZF1200
Full-Automatic Overall Migration Tester AUTO ZF1200 has an integrated system design of water bath evaporation, heating and drying, drying and cooling, and constant temperature weighing. It is suitable for testing the total migration (non-volatile matter, evaporation residue) and other items in the fields of purified water, pharmaceutical packaging materials, food packaging, cigarette tipping paper and chemical reagents. It can also be applied to the water content, loss on drying and other items of solid samples, and the total dissolved solids content test in water quality testing.
6 GBPI hot selling plastic raw materials producion high precise melt testing instrument
GBPI Melt Flow Indexer is used to measure thermoplastic melt mass flow rate (MFR) and melt volume flow rate (MVR). It is suitable to meassure meltg flow charactor of PP,PE,POM, AR,PC,ABS plastic and plastic productions, widely used in plastic raw materials production, petrochemcial industry, scientific research departments and commodity inspection department.
Inclined Plane Friction Tester Inclined Surface Coefficient Of Friction Tester
GM-F1 Inclined Coefficient of Friction Tester is expert applicable to the resolve of stationary coefficients of paper board, friction of paper, sheets, plastic films, convey belts and additional substances. By challenging the frictional possessions of substances, the open presentation of packages, packing rapidity of packers and additional indexes could be regulated to meet necessities for production.Different functions from other coefficient friction testers  (cof)    
 Folding Endurance Tester Folding Endurance Tester on paper for cardboard and other flaky materials
Folding Endurance Tester mainly test the folding endurance on paper, cardboard and other flaky materials, but the thickness less than 1.25mm. Its main technical indexes and performance parameters accord with related national standards.
Oxygen Gas Permeability Tester Coulometric Sensor Method Oxygen Permeability Analyzer Y310L
Introduction This product is designed and manufactured based on the coulometric sensor method and conforms to GB/T 19789、ASTM D3985.This instrument can be used to measure the oxygen transmission rate of barrier materials with high and medium barrier properties with high accuracy and high efficiency.Y310Lis applicable to the determination of oxygen permeability of plastic films, sheeting, paper, and other packaging materials used in food, pharmaceutical, medical apparatus, consumer products, photovoltaic and electronic industries, etc.
Heat Shrink Tester Heat Shrink Tester ASTM D2732 GBK-1
GBK-1 Heat Shrinkage Tester is for testing the heating shrinkage of packaging films submerged in liquid in different temperatures.
water vapor transimission rate WVTR MVTR water vapor permeability analyzer electrolytic sensor method for flexible barrier sheet materials test - W201
Water vapor permeability analyzer is used to test water vapor transmission rate (WVTR) of films or sheets materials for flexible packaging.
Gas Permeability Analyzer N530 L Gas Permeability Analyzer
Introduction Based on the test principle of the differential pressure method, N530L is designed with reference to the GB/T 1038 standard and used to test the gas transmission rate (quantity) of film or sheet materials.
Xenon arc lamp aging test chamber Xenon arc lamp aging test chamber GB-OXD-15P
  1.Profile Xenon lamp aging test chamber simulates the full spectrum lamp with Xenon arc lamp to reappear the destructive wave. It serves for the environmental simulation and accelerated test for research and development, product development and quality control. Besides, the chamber also applies to the choice of new material, weathering test after composition of material and improvement for the current material. It simulate different environment, and show the material changes under the explosion of sunlight.   The chamber meets the standard: GB/T16585-1996 , GB14522-93 , GB/T16422.3-97, ASTM D2565 and so on. The Chamber is to determine the color fastness, aging resistance of textiles, plastics, coatings, rubber products or other materials by objecting to the simulated conditions of nature weather (sun, rain, temperature and humidity, etc.).     Technical parameters   2.Material of construction u Full spectrum lamp u Optional filter system u Water spraying function u Humidity control u Temp. control system in the chamber u Sample fixed hold of irregular shape u USA imported xenon arc lamp u Easy installation and operation, seldom daily maintainance. u Service life time deepens on the irradiance level, usually 1600hrs. It’s easy to replace the lamp, with filter of long service life time to ensure the necessary spectrum. 3.Technical parameters Model No., equipment name GB-OXD-15P Xenon aging test chamber Interior sizes   W500×D500×H600mm  Exterior sizes W1050×D1050×H1750mm (or so) Temperature range 0℃~80℃ Controller imported programmable 7inch touch screen Machine components material inner and outer 304# stainless steel Sample holder Aluminum alloy frame base Protection device residual-current circuit breaker (RCCB) to control the warning for loop overload, thermal protection and water shortage protection. Temp. deflection ±2℃  (without lighting) Humidity range 30%~98%R.H Humid. deflection ±2.5%R.H(Humid.≥75%R.H); ±3%R.H(Humid.≤75%R.H) without lighting Light source imported full spectrum xenon arc lamp(average useful life 1600hrs) Raining time 1~9999min (adjustable) Raining period 1~240min, interval(cut)adjustable lamp power Test period for Temp., irradiation, condensation, spray can be adjustable Lamp 1.8KW Wave length range 290-800nm heating power (or so) 4.0KW humidification (or so) 2.0KW Light irradiance 1200w/m2 Distance between arc center and sample holder: 350~380mm Revolving speed of sample holder ≥1r/min  water spray period a. spray time: 0~99h59min (Continuing or adjustable) b. stop time: 0~99h59min, (Continuing or adjustable)   lighting time Continuing programming control available black panel temp. 85±3℃ cooling method Mechanical wind cooling; Room temp. less than 26℃ is recommend, relative humid: ≤85%R.H; humid. and temp. tested after 2 hours under idle condition. 4.Temperature & humidity running control system controller imported programmable 7inch touch screen precision range set precision: temp. ±0.1℃, humid: ±2%R.H, indicated precision: temp.±0.1℃,humid.: ±1%R.H temp. & humid. sensor Platinum Resistance(PT100Ω/MV) black panel temp. double-metal black panel temp. thermometer water-supplying system auto-control humidication water-supplying, Xenon arc lamp with cycling cooling water circulation system low noise heat-resistance conditioning motor, multi-blade centrifugal wind wheel control system mainly consists of operation panel, central controller, kinds of key-pressing sw., status indicating lamp, excution electric device etc.. 5.Structure section of machine body The chamber consists of several section: chamber body, control system, refrigeration system, heating system, humidation system, wind system, raining system, lighting system and so on. Chamber body a. With integrated structure, the chamber consists of up left part as working room, up right part as electric controller which is convenient to control, down part as compressor cooling group, sample holder rotation device, Xenon lamp condensation water box, water pump and other executive devices. b. Inner wall of chamber adopts international SUS304# material. c. Temp. insulation material is polyurethane foam and ultra-fine fibre glass, with good temp. insulation result, no frost and condensation on the external surface of chamber. d. condensate water outfall set at the bottom of chamber e. Environmental heat-resistance silicon sealing tape as the material of door frame. f. Viewing window with eye-protective film on its surface to protect eyes from being injured by Xenon lamp. external chamber body a. Seal of door adopts the double-layer of refined silicone rubber with reliable sealing effect and no aging or hardening phenomenon under high or low temperature. b. Single door (embedded handle); c. Viewing window, antifrost device and lamp equipped on the door viewing window Size:25 cm W × 30 cm H;equipped with Anti-radiation hollow glass 6.Electric control section of chamber a. As the core part of chamber b. Air pressure switch as the main switch to control the main circuit; c. Safety measures for electric section: it warns and cut electricity automatically after tested the action from following protection devices: a) overheat protection in working room b) lockage of phase, leakage protection c) overcurrent protection of motor d) overpressure/overload protection of cooling machine e) short out/overload protection of heater, humidifer f) fusing protection of fuse 7.Working section of chamber Condensation section of compressor. a.Cooling system: as the core part of cooling system, we adopt one set of compressor of Tecumseh from France in this case to ensure the cooling requirement in the working room. b.For adjustment technology and design of cooling system, we take an efficiency processing way to ensure the adjustment for the cooling amount and consumption of cooling system under the normal running, to make the failure rate down to the economical statue. c.Cooling evaporator: it locates in interlayer at one side of chamber which ventilate by force from blast motor to exchange heat fast. d.Cooling method of cooling system: forced air cooling Cooling refrigerant:Environmental R404a; Heating system a. Heating method: heating directly in the chamber; b. Military level stainless steel heating tube used, with fast and stable heating to keep temperature in the working room from rapid change. It with corrosion resistance, anti-high-low temperature, no leakage and other advantages. c. With SSR (solid relay)output control, without noise, reliable working, long service life time, fast switching, low interference from outside, and easy operation etc.. Rain system.   it consists of nozzle, solenoid valve, water-supplying and connecting pipe. Lighting system. It consists of xenon lamp, lamp cover, lamp contactor and other controlling parts. Energy compensation is got by adjusting samples distance, pressure and current. Wind system  It locates in the interlayer at the back of chamber, there are heater, fan blade, evaporator, PT100 temperature samples sensor etc.. when wind machine running, the air is intaken to the channel from working room, and blow out from the bottom after cooled; the air exchanged in the working room with samples is intaken again to the channel and mix; after several circulation, it will reach the purposed temperature, and ensure the high index of temp. and humid in the chamber at the same time. Cooling dehumidification system take the compressor of world brand Tecumseh from France to keep constant temperature, decrease the humidity in the working room and cool the xenon lamp. Humidification Steam generator: to generate steam from water Water level control: control the water inlet by solenoid valve, and water level by liquid level switch to provide the signal for water-supply and warning. Air circulation section Cycling channel and winding machine inside the chamber, it uses the high efficiency cooling machine and energy adjusting system, efficiency heat exchange to reach the aim of temperature change, which also improves the airflow and heat exchange between airflow, heating and humidification, as a result, it improves the humidity uniformity in the working room. 8. Enclosured files: operation manual, warranty card 9. Machine running requirements Temp. 5℃~+32℃ Humidity ≤85% Power supply AC220(±10%)V/50HZ    10. Core components parts Remark: replacement of some small parts of the same quality is possible because of material shortage.    
  • Facebook
  • Linkedin
  • Youtube
  • Twitter

Copyright @ 2026 Guangzhou Biaoji Packaging Equipment Co.,Ltd. All Rights Reserved.

Chat now

Inquiry Now

Home

Products

NEWS

contact