Gx-B2 Disk Stripping Tester

To test the ink layer bonding strength of printed (intaglio) plastic film, composite film, cellophane and so on; test the layer bonding status formed by vacuum coating, surface coating and composite technology etc. It meets the GB/T 7707-2008 standard The intaglio prints for decorating.

Inquiry now
Product Detail

Standards

GB/T 7707-2008

 

Specifications

Item

Technical Parameters

Peeling pressure

100N

Peeling speed

0.8M/S

Disc A size

170mm width55mm

Disc B size

65mm width55mm

Instrument size

400mm×225mm×340mm

Power

1000W

Power supply

AC220V 50Hz

Weight

21Kg

Send A Message

Leave us a message, we will get back to you ASAP.

Related Products
Ink Rub Tester Printing Ink Rub Resistance Tester
  GX-C3S Printing Ink Rub Resistance Tester Product Introduction Designed per international standards, this tester detects abrasion resistance of printing ink layers and surface coatings. It accurately evaluates print rub resistance, ink adhesion and coating hardness to support quality control and material optimization. Test Principle Rub printed samples with clean offset paper under fixed load. After preset rub cycles, test specimen density and compare with initial value to calculate ink abrasion resistance. Applicable Standards ASTM D5264, TAPPI T830 Technical Parameters Item Specification Rubbing Load 8.9 N (2lb); 17.8 N (4lb) Rubbing Speed 10-200 cpm Rub Block 1(8.9N) 910g±10g Rub Block 2(17.8N) 1810g±10g Rub Mode Arc reciprocating motion Rub Cycles 1~999999 Specimen Quantity 2 pcs Overall Dimension 570mm×400mm×265mm(L×W×H) Power 600W Power Supply AC220V 50Hz Net Weight 24.5kg Product Features Equipped with color touch screen for easy parameter setting and operation. Fully automatic running, one-key start & auto stop for simple operation. High-precision ball screw ensures stable running, long service life and energy saving. High testing accuracy for reliable experimental results. Standard-compliant structure guarantees accurate test data. Built-in printer to output test reports directly. Arc reciprocating rub simulates real complex friction condition of practical usage. Adjustable rubbing cycles and rubbing speed. Overload protection: auto stop when load exceeds preset threshold. Application Fields Applied for printing packaging, plastic coating, surface finish industries, used to check ink layer wear and surface coating abrasion performance of printed products.
Adhesive Tape Roller Pressing Machine Plastic Film Adhesive Tape Rolling Pressing Machine
The Adhesive Tape Roller GX-Y2 is suitable for plastic film and cellophane decorative prints (including composite film prints) produced by gravure printing process. It is also used to test the adhesion state of the surface layer formed by vacuum coating, surface coating, compounding and other related processes.
Ink Rub Tester GX-C2 Rub Tester Ink Rub Tester - Rub Tester for Ink, Coating
GX-C2 Rub Tester is suitable for testing the abrasion resistance of printing ink layer of printed matter, the abrasion resistance of PS plate photosensitive layer and the abrasion resistance of surface coating of related products. It can effectively analyze the problems of poor rub resistance of printed matter, peeling of ink layer film, low printing endurance of PS version and poor coating hardness of other products.
Professional GX-B3  Disc peeling tester Plastic Film-Disc Peeling Testing Machine-with CE ISO Certificate supplier GX-B3 Disc peeling tester Plastic Film-Disc Peeling Testing Machine-with CE ISO Certificate
GX-B3 type disc peeling tester is used for testing the adhesion fastness of printing ink layer of plastic film and cellophane decorative printed materials (including composite film printed materials) produced by gravure printing process. It can also be used to test the adhesion state of the surface layer formed by vacuum coating, surface coating, compounding and other related processes.  
Professional high accuracy barrier film Electrolytic sensor method water vapor permeability analyzer-W203 2.0 supplier high accuracy barrier film Electrolytic sensor method water vapor permeability analyzer-W203 2.0
W203 2.0 Water Vapor Transmission Rate Tester Electrolytic Method | High Barrier Materials WVTR Testing Product Introduction W203 2.0 is developed based on the electrolytic test principle, designed and manufactured in accordance with GB/T 21529, ISO 15106-3 and other international standards. It tests water vapor transmission rate of samples under controlled temperature and humidity, widely used for high barrier materials in LCD, solar cells, chip packaging, pharmaceuticals, food and more. Get a Free Quote Today   Test Principle W203 2.0 adopts the electrolytic method. The pre-treated sample is fixed in the test chamber, separating it into wet and dry sides. Humidified nitrogen flows on one side of the film, while dry nitrogen (carrier gas) flows on the other side at a fixed rate. Due to humidity gradient, water vapor permeates from the wet side to the dry side, carried by dry nitrogen to the electrolytic sensor. The WVTR value is calculated from the electrical signal output by the sensor.   Compliant Standards 2025 Chinese Pharmacopoeia 4010 GB/T 21529-2008 ISO 15106-3 DIN 53122-2 YBB 00092003-2015 ASTM F3299 JIS K7129-3   Technical Specifications Item Value Test Range 0.001~40 g/(m²·24h) (Film & Sheet) Resolution 0.0001 g/(m²·24h) Temperature Range 15 ~ 45℃ Temperature Accuracy ±0.1℃ Humidity Range 5 ~ 90%RH Humidity Accuracy ±1%RH Test Area 50.24 cm² Sample Size Φ100 mm Test Chambers 3 channels (independent data)   Key Features High-sensitivity sensor for ultra-high barrier materials in electronics, photovoltaics, displays. Automatic pneumatic clamping system, one-key locking, excellent sealing. Precise temperature & humidity control: ±0.1℃, ±1%RH. 3 independent test chambers for high-throughput testing. 11.6-inch HD touch screen, real-time test curves display. Intelligent OS with audit trail, multi-level user rights, GMP compliant. Calibrated with national standard substances for accurate & authoritative data.   Applications Display MaterialsLCD sealant, SiNx passivation film, modified PET, etc. Chip PackagingFR-4, BT resin, PI substrate, ABF film, ceramic substrate. Solar MaterialsSolar backsheet, butyl film, ALD Al₂O₃, EVA/POE film. Packaging ComponentsPharmaceutical tubes, BFS bottles, infusion hoses, containers. Pharmaceutical & FoodUltra-high barrier films and packages for medical and food use.
migration testing in food packaging GBPI Migration Testing equipemnent In Food Plastic Packaging Migration & Non-volatile-matter Content Tester
  ZF3600 Full-automatic Total Migration Tester is applied to determinate the dissolution amount of packaging materials in different simulant soaking solutions.  
Professional Water Vapor Transmission Rate Tester supplier Water Vapor Transmission Rate Tester
The W401 2.0 Water Vapor Transmission Rate Tester is designed and manufactured in accordance with ASTM F1249 and ISO standards. Adopting advanced infrared moisture sensor technology, it provides wide-range and high-efficiency testing of water vapor transmission rate (WVTR) for high, medium and low barrier materials.
drying oven DHG-9030A Drying Oven
It is used to dry, bake, melt and sterilize test sample, widely used in industrial and mining enterprises, laboratory, research institute, inspection agency, college and so on.
filling and sealing machine Automatic Rotary Pouch Spout inserting and Sealing Machine GF-1600H
This sealing/filling/capping machine(Packaging Machine/Packaging Machinery)is applicable for Fruit Juice/Salt /Sanitizing Gel/Skin Care/Sugar Powder/Tomato Sauce/ Ketchup/ Detergents Soap Packing in form of top/corner spout pouch or top/corner spout stand up pouch, 3-side sealing bags, and doypacks.
Vacuum Decay Leak Detection Tester Dual Pressure Methods Vacuum Decay Leak Detection Tester AUTO GBM-L2
Introduction AUTO GBM-L2 Dual-Pressure Methods Vacuum Decay Leak Detection Tester adopts the test principle of vacuum decay method/pressure decay to detect micro-leakage of finished packaging. It can be applied to packaging systems composed of vials, ampoules, Leakage detection of pre-filled needles, eye drop bottles, HDPE bottles, infusion bottles/bags and other pharmaceutical packaging, food packaging, and chemical industry packaging.   Test principle The host is connected to a sealed test chamber customized according to the sample. When performing the vacuum decay method test, the instrument evacuates the test chamber, and a pressure difference is formed inside and outside the sample. Under the action of the pressure, the gas/liquid in the sample enters the test chamber through the leak hole. The main engine uses the absolute pressure sensor and the differential pressure sensor to monitor the pressure change in the chamber to judge whether the sample leaks. When performing the pressure decay method test, the instrument fills the test chamber with a predetermined air pressure, and the gas in the test chamber enters the sample through the leak hole. The host uses absolute pressure sensors and differential pressure sensors to monitor the pressure changes in the chamber to determine whether the sample is leaking.   Standard ASTM F2338-2009(2013),  YY-T 0681.18-2020,  USP<1207.2>, ASTM F2095   Specification Item Parameters Absolute Pressure Testing Range (0 - 300) kPa Differential Pressure Testing Range (-2 - 2) kPa Detection Sensitivity 1 - 3 μm Balancing/Testing Time 1 - 3600 s Vacuum Purge Time 1 - 3600 s Set Flow Rate 0 - 3 mL/min Testing System Dual Sensor Technology/Dual Cycle Testing Testing Chamber Customized according to the sample Applicable Products Vials, Ampoules, Prefilled Syringes, Infusion Bottles/Bags, etc. Detection Principle Vacuum Decay Method/Pressure Decay Method Dimensions of the Main Unit 495 mm455 mm280 mm Ambient Temperature 20℃ - 25℃ Relative Humidity 40% - 60% Working Power Supply AC 220V, 50HZ   Features u Dual-Pressure Methods, to help solve testing difficulties The double combination of vacuum decay method and pressure decay method solves the problem of easy misjudgment and false negative for freeze-dried powder injections containing vacuum in the bottle using a single vacuum decay method. Based on dual-sensor and dual-circulation system technology, high-quality absolute pressure sensor and differential pressure sensor, with an accuracy of 0.1% FS, can effectively detect large and small leaks, accurately calculate the leak hole diameter, and give a pass or fail judgment.   The instrument has low sensitivity and good test repeatability For rigid samples, the detection sensitivity is as low as 1 μm, and the test repeatability is as low as 0.8%. The instrument has stable performance, low noise and good repeatability. u Imported brand accessories, excellent performance Imported brand vacuum pump, pumping rate up to 3 L/s, noise as low as 50 DB, high ultimate vacuum, convenient oil level detection and replacement. The imported gas mass flow controller can simulate micro-leaks arbitrarily, with a resolution of 0.001 mL/min, which provides a reliable guarantee for the method verification of instrument sensitivity. u Large size touch screen, intelligent operation Color 7-inch touch screen, clear view, sensitive touch, easy to operate. Equipped with a micro-printer, USB data interface, and supports PC software measurement and control operation. The test software is designed according to the GMP appendix "Computerized System". It has an audit trail function and multi-level authority settings for users, which can meet the needs of the pharmaceutical industry for data traceability. u Personalized customization to meet the needs of different samples For different test samples, it supports customization of suitable test chambers to meet the needs of different tests. For the same type of samples, it supports customized nesting mode, which can realize the sharing of a test chamber for samples of various specifications.   Application       Freeze-dried powder injection Injection Prefill needle       Eye drops Plastic Ampoule BFS Infusion bags   Factory configuration Standard Host machine, vacuum pump, test chamber and 3 sets of yin and yang control (customized as required), 11-inch touch panel, professional software (GMP) Optional Imported gas flow meters, air compressors, printers, calibration certificates  
water vapor permeability test Water Vapor Permeability Analyzer Weight Increase Method W501
water vapor permeability analyzer is to test the water vapor transmission rate (WVTR) of films or sheets materials.
Electronic Tensile Tester Electronic Digital Tensile Tester Machine GBL-L
GBL-L Electronic Digital Tensile Tester Machine apply to test the tensile strength, peeling strength, heat sealing strength and tearing strength of plastic film, composite film, tape, soft packaging material, rubber sheets, paper, non-woven fabrics and other packaging materials, widely used in industries of membrane, packaging, pharmaceuticals, food industries, inspection agency, research institute, college and so on.
  • Facebook
  • Linkedin
  • Youtube
  • Twitter

Copyright @ 2026 Guangzhou Biaoji Packaging Equipment Co.,Ltd. All Rights Reserved.

Chat now

Inquiry Now

Home

Products

NEWS

contact