Product Detail

 

 

GBPI Oxygen Permeabililty Tester Y310 Features:

1. Coulometric sensor method: the main national method, the general international method. 

2. Automatic temperature monitor, program controlled temperature increase and decrease, precision: 0.1℃. 
3. Humidity control: dual gas flow method, stable, precision 1%RH; gas flow auto compensation. 
4. Y310 Oxygen Permeation Analyzer test range can extend to 260000 cm3/(m2·24h) by installing extra fittings. 
5. By installing extra fittings, can extend function to test finished packaging product, such as plastic bowl, bottle, bag and so on. 
6. With quick test function. 
7. Can extend to maximum 12 chambers. 
8. Standard gas calibration and standard film calibration. 
9. Three chambers can do independent test and independent report for two different samples; support cross testing of two chambers. 
10. Built-in computer, can work without external computer. 
11. Touch screen. 
12. Auto judgment and auto stop. 
13. Sensor auto protection. 
14. Real time display and auto record of curves and data of transmission rate, oxygen density, humidity and temperature. 
15. Will not change the properties of test sample during testing; support continuous testing in certain temperature and humidity.

Oxygen Permeability Tester

Y310 Oxygen Permeability Analyzer is to test the oxygen transmission rate (OTR) of films or sheets materials. 

Oxygen Transmission Rate (OTR) Tester Applied to: 
1) Plastic film, composite film, aluminum foil, aluminized film,etc; 
2) Sheet, panel, rubber, ceramics,etc; 
3) Packaging containers, such as:glass, bottle, cans, boxes, etc; 

4) Expanding application: solar panel, LCD film, medical patch, etc. 

 

Widely used in quality inspection organizations, drug control institutions, research institutes, packaging, thin film, food companies, pharmaceutical enterprises, personal care industry, electronics industry and so on.

 

Y310 OTR Analzyer Technical Specification:

Test range

0.02~16500 cm3/(m2·24h)

Test accuracy

0.001 cm3

Temperature range

15~45℃(5~50℃ Optional)

Temperature accuracy

 ±0.1℃

Humidity range

30~90%RH, 100%RH

Humidity accuracy

±1%RH

Number of test sample

1~3 pcs

Test area

50.24cm2 

Sample size

Φ100mm

Sample thickness

≤ 3mm

Carrier gas

99.999% N2 (user provide)

Gas supply pressure

0.1~0.2 Mpa

Carrier gas port

1/8 inch metal port

Power supply

220V 50Hz

Power

750W

Instrument size

700mm × 560mm × 370mm

Weight

100kg

 

Y310 Oxygen Permeation Analyzer Configuration and Software

Main machine body, software, communication cable, Φ100 sample cutter, 1/8 inch copper tube, sealing grease, clip connector, water injector, spanner, standard test plate 
User provide: nitrogen (99.999%), oxygen (99.999%), pressure releasing valve, computer 
Optional (for purchase): test accessories, standard film, sealing grease, special clips, pressure releasing valve, computer

1. Y310 Oxygen Permeability Tester adopt specialized software. 
2. Support workflow testing, can set workflow freely. 
3. Visual display of experiment data and curves of temperature, humidity, pressure and transmission rate. 
4. Easy to use, wholly automatic. 
5. Powerful data analysis; can distinguish external disturbance not to affect testing. 
6. Can option to display or not display various curves. 
7. Intelligent error correction to prevent wrong operation. 
8. By manual operation, user can enlarge any part of the interface and curves to make detailed analysis. 
9. Support quick test. 
10. Support online diagnosis.

 

GBPI Y310 Confirms to standards

GB/T19789-2005、YBB00082003-2015、ASTM D3985、ASTM F2622 、ASTM F1927、ASTM F1307、ISO 15105-2、DIN 53380-3、JIS K-7126-B

Send A Message

Leave us a message, we will get back to you ASAP.

Related Products
Oxygen Permeability Analyzer Y310 2.0 Gas Analysis Equipment Oxygen Permeability Analyzer
This product is based on the test principle of the Coulomb oxygen analysis sensor and is designed and manufactured with reference to the ASTM D 3985 standard. It is used to determine the oxygen transmission rate (quantity) of film or sheet materials.
Oxygen Permeability Analyzer Y110 L Oxygen Permeability Analyzer - Coulometric Sensor Method
This product is based on the testing principle of coulometric oxygen sensor, designed and manufactured with reference to ASTM D3985 and other standards. It adopts high-precision imported oxygen sensor with high testing accuracy. It is suitable for oxygen transmission performance testing of films, sheets, papers, packaging and related materials in the fields of food, pharmaceuticals, medical devices, daily chemicals, photovoltaic electronics, etc. It provides wide range and high efficiency oxygen transmission rate testing for high, medium and low oxygen barrier materials.
Oxygen Gas Permeability Tester Oxygen Permeability Analyzer - Coulometric Sensor Method
This product is based on the testing principle of the coulometric sensor method testing Oxygen, and is designed and manufactured with reference to ASTM D3985 and other standards. Adopting high-precision imported oxygen sensor, high test accuracy,it is suitable for oxygen transmission performance testing of films, sheets, paper, packaging and related materials in the fields of food, medicine, medical equipment, daily chemicals, photovoltaic electronics, etc., and provides a wide range and high-efficiency oxygen transmission rate detection for high, medium and low oxygen barrier materials.
Oxygen Gas Permeability Tester Coulometric Sensor Method Oxygen Permeability Analyzer Y310L
Introduction This product is designed and manufactured based on the coulometric sensor method and conforms to GB/T 19789、ASTM D3985.This instrument can be used to measure the oxygen transmission rate of barrier materials with high and medium barrier properties with high accuracy and high efficiency.Y310Lis applicable to the determination of oxygen permeability of plastic films, sheeting, paper, and other packaging materials used in food, pharmaceutical, medical apparatus, consumer products, photovoltaic and electronic industries, etc.
Headspace Gas Analyzer Headspace Gas Analyzer-GB-DK
Product Introduction The headspace gas analyzer adopts the destructive puncture detection method and is equipped with high-precision oxygen sensors and carbon dioxide sensors to accurately detect the O2 and CO2 content of hollow packaging containers such as packaging bags, bottles, cans, etc. The analysis of the content of the headspace gas in the packaging can make a reasonable judgment on the product quality, the validity of the shelf life prediction, and the rationality of the packaging design. At the same time, it can also be used as a means of packaging tightness testing. It is a better choice for modified atmosphere preservation (MAP, CAP) packaging, large infusion bottles (bags), residual oxygen in the headspace of prefilled needles, residual oxygen detection in vials, and the results of residual oxygen detection for various food and medicines. Nowadays, the headspace gas analyzer has become an important method to check the quality of packaging design and one of the important methods to verify the product shelf life. Our headspace gas analyzer GB-DK can quickly detect O2 in production lines, warehouses, laboratories and other occasions. And CO2 content to guide production.   Test principle The gas in the sample is drawn into the sensor by a vacuum pump. The sensor outputs the current and voltage signals of the O2 and CO2 (optional) concentration in the gas in the sample in real time. The instrument calculates the content of O2 and CO2 in the gas by obtaining the current and voltage signals output by the sensor. After reaching the end conditions of the experiment, the test stops, and the instrument records the concentration of O2 and CO2 in the measured gas in the sample.   Technical parameter Item Parameter Gas to be Measured O2 (standard configuration) CO2 (optional) Measurement Principle Fluorescence optics infrared absorption Measurement Range 0%~25% (for O2) 0%~100% (for CO2) Measurement Accuracy ±0.2% ±2% Sample Size ≥5 mL (at standard atmospheric pressure) (for O2) ≥20 mL (at standard atmospheric pressure) (for CO2) Dimensions 350 mm (L)×330 mm(W)×200 mm(H) Power Supply 220 VAC±10 % 50Hz/120 VAC±10 % 60 Hz Net Weight 5kg    Features 1.Using high-precision sensors, high accuracy, good stability, long-term operation, long service life. Over-range automatic protection function to avoid damage to important sensors when the instrument fails. 2.The needle/probe safety holster is used to ensure safe testing and fast sampling. 3.Oxygen and carbon dioxide can be detected at the same time, and carbon dioxide gas can be selected for analysis according to different user needs. The sampling volume is at least 3 ml. 4.Built-in operating system, the system is equipped with an ARM control system to control the host through a touch screen (testing equipment and control software are combined into one); at the same time, the system can be expanded, such as connecting to the laboratory LIMS system. 5.The software is designed according to the requirements of the computerized system in the new version of the GMP appendix, and users are divided into multiple levels such as operators and administrators (such as administrators, operators, observers, etc. but not limited to these levels). 6.It has the audit trail function, which can realize the audit trail of the system, project operation, and method to ensure the safety and integrity of the test data. 7.Personalize the test report, set the report module that needs to be displayed, and output the report in PDF mode. The micro printer can print test reports in real time.  
water vapor transmission rate WVTR MVTR water vapor transimission rate testing instrument for plastic packaging properties test -
Three test chambers water vapor permeability analyzer using infrared sensor is the highest accurate water vapor transmission rate tester, meeting standard of ASTM F1249.
Moisture permeation rate tester Water Vapor Permeability Analyzer For LDPE Film Gravimetric Method - W533
A533 water vapor permeability analyzer is to test the water vapor transmission rate (WVTR) of films or sheets materials.
Elmendorf tearing strength tester GBD-S ASTMD689 Elmendorf Tearing Strength Tester For Fabric And Paper
The tear tester (elemendorf method) tests the tear resistance of paper, film, PVC, polyolefin, polyester, composite film, sheet, non-woven fabric, textile, paper, and board, etc. It is controlled by computer automatically and can be tested independently.
water vapor transimission rate WVTR MVTR water vapor permeability analyzer electrolytic sensor method for flexible barrier sheet materials test - W201
Water vapor permeability analyzer is used to test water vapor transmission rate (WVTR) of films or sheets materials for flexible packaging.
Automatic Torque Tester Non-Destructive Cap Torque Tester HP-D1 Automatic Torque Tester Non-Destructive Cap Torque Tester
The HP-D1 Automatic Torque Tester HP-D1 is innovated to test cap torque for detecting sealing performance of packaging containers, such as plastic bottles, liquid boxes, cans, etc.
Crush Tester Crush Tester Paper Packaging Test Equipment
Paper Packaging Test Equipment 
Vertical Heat Seal Tester Vertical Heat Seal Tester GBB-C
Product Introduction GBB-C vertical heat seal tester can accurately measure the heat sealing temperature, heat sealing time, heat sealing pressure, and other heat sealing performance parameters of plastic packaging vertical bags, paper-plastic composite vertical bags and metal composite vertical bags(boxes). The heat sealing performance of samples of different materials are different. And the best heat sealing conditions can be accurately obtained through the determination of their heat sealing performance parameters.   Testing Principle Put the sample on the lower tray of the instrument, adjust the appropriate height according to the size of the sample, set a certain sealing temperature, time and pressure as required, and start the instrument with one key. The fixture on the instrument will heat seal the sample according to the setting parameters. Under the manual state, step on the foot switch, and the heat sealing knife is pressed. The heat sealing time is determined by the value set by the time control. In the automatic state, the upper and lower heat sealing knives of the heat sealer will automatically heat seal repeatedly according to the set time. Standards ASTM F 2029 Specifications Item  Technical Parameters Temperature Range Room temperature ~ 250℃ Temperature Control Accuracy ±1℃ Hot Sealing Time 0.1s ~ 99.99 h Hot Sealing Pressure (0~1) MPa Hot Sealing Surface Upper and lower sealing knives: 300×5.5 mm, smooth; lower sealing bar with silicon pad Operation Mode Two modes: automatic and manual, with external cylinder Gas Source Compressed air Overall Dimensions 730(L) mm×400(B) mm×535(H) mm Weight 33.8kg Power 1200 W Power Supply AC 220V, 50Hz     Characteristics u High progress imported quality sensor, quality assurance Original imported temperature sensor, wide temperature control range, high sensitivity, temperature control accuracy of ± 1 ℃, it has ultra-high stability and ultra-low failure rate. u Independent control of heat sealing temperature The rear of the heat sealing knife is equipped with a temperature sensor, and the temperature control of the inner and outer sealing knives is independent and set separately. u Personalized test selection Manual testing and automatic testing are free to choose. The automatic mode is time-saving and convenient, and the repeatability is fully automatic for heat-sealing the sample; the manual mode is equipped with a suitable foot switch, step on the foot switch, the heat sealing knife is pressed, and the safety protection is easy to operate. u New air drive system The drive system consists of a pressure gauge, a pressure regulating valve, and a cylinder. After the compressed air is introduced, the pressure is adjusted through the pressure valve, the air pressure can be accurately locked, and the heat sealing clamp is pneumatically driven, which is convenient and efficient. u Wider range of customized services The anti-sticking function of the heat sealing knife can be upgraded as needed, experience upgrade, and it is more intuitive and convenient to determine the best heat sealing conditions. The shape, size and smoothness of the sealing knife heat cover can be customized to meet different scientific research needs.   Application     Plastic stand up pouch Paper plastic stand up pouch     Aluminized stand up pouch Milk Boxes  
  • Facebook
  • Linkedin
  • Youtube
  • Twitter

Copyright @ 2025 Guangzhou Biaoji Packaging Equipment Co.,Ltd. All Rights Reserved.

Chat now

Inquiry Now

Home

Products

News

contact