packaging testing equipment Water Vapor Permeation Tester
Products
Home /

Physical Property Test Equipment

/

Coefficient of Friction Tester

/Inclined Surface Coefficient Of Friction Tester

Inclined Surface Coefficient Of Friction Tester

GM-F1 Inclined Coefficient of Friction Tester is expert applicable to the resolve of stationary coefficients of paper board, friction of paper, sheets, plastic films, convey belts and additional substances. By challenging the frictional possessions of substances, the open presentation of packages, packing rapidity of packers and additional indexes could be regulated to meet necessities for production.Different functions from other coefficient friction testers  (cof)

 

 
  • Brand:

    GBPI
  • Item NO.:

    GM-F1
  • Product Origin:

    CHINA
  • Shipping Port:

    SHENZHEN
Inquiry now
Product Detail

 

Standards

ASTM D4918-Standard Test Method for Coefficient of Static Friction of Uncoated Writing,

ASTM D202-Standard Test Method for Coefficient of Static Friction of Uncoated Writing and Printing Paper by Use of the Inclined Plane Method (Withdrawn 2010),

TAPPI T815-Coefficient of static friction (slide angle) of packaging and packaging materials (including shipping sack papers, corrugated and solid fiberboard) (inclined plane method),

 

Features

Imported component, high precision.

It can be tested independently without the computer, data automatically processed.

 

Specifications

 
Item Technical Parameters
Angle Range 0°~85°
Resolution 0.01°
Sensor Accuracy 0.1 %FS
Angular Velocity 0.1 °/s~10 °/s
Slide Specifications - 63.5 mm×63.5 mm (200 g)
- 90 mm×100 mm (1300 g) (Optional)
- 63 mm×75 mm×25 mm (235 g±10 g) (Optional)
Note: Other slide masses can be customized.
Dimensions 400 mm(L)×366 mm(W)×173 mm(H)
Display Mode Touch screen
Rated Power 250 W
Power Supply AC 220 V, 50 Hz
Net Weight 15 kg

 

 
Send A Message

Leave us a message, we will get back to you ASAP.

Related Products
COF tester GM-1 0-10N plastic film packaging coefficient of friction tester
The coefficient of friction tester is used to test the coefficient of frictionof plastic film, thin sheet, paper and so on, widely used in packaging industry, film-making companies and packaging material inspection agencies.
coefficient of friction tester New advanced 0.01~0.999 film packaging COF GM-6 coefficient of friction tester GM-6
Coefficient of friction testers is used to test the coefficient of frictionof plastic film, thin sheet, paper and so on, widely used in packaging industry, film-making companies and packaging material inspection agencies.
COF tester GM-4 Coefficient of Friction Tester
  The coefficient of friction tester GM-4 is a measuring instrument developed and manufactured by the Guangzhou Biaoji R&D team based on various test standards of GB, ISO, ASTM and market demand. The measured friction coefficient determines the smoothness and opening difficulty of the film. and uniformity can be accurately determined, so as to correctly guide the production. It is suitable for measuring the static friction coefficient, dynamic friction coefficient and peel strength of plastic films, composite films, aluminum foils, aluminized films, plates, rubber, ceramics and other materials when sliding.        
Electronic Tensile Tester Electronic Digital Tensile Tester Machine GBL-L
GBL-L Electronic Digital Tensile Tester Machine apply to test the tensile strength, peeling strength, heat sealing strength and tearing strength of plastic film, composite film, tape, soft packaging material, rubber sheets, paper, non-woven fabrics and other packaging materials, widely used in industries of membrane, packaging, pharmaceuticals, food industries, inspection agency, research institute, college and so on.
Vacuum Decay Leak Detection Tester Dual Pressure Methods Vacuum Decay Leak Detection Tester AUTO GBM-L2
GBM‑S1 Cap Seal Integrity Tester for Bottle Caps & Easy-Open Containers GBPI GBM‑S1 Cap Seal Integrity Tester, Positive Pressure Bubble Water Bath Leak Tester Product Introduction GBM‑S1 Cap Seal Integrity Tester adopts compressed air as power source and high‑precision electronic pressure sensor for measurement. Controlled by microcomputer, it effectively tests the sealing process and sealing performance of closures, providing scientific basis for defining relevant technical requirements. It is suitable for mineral water & purified water bottle caps, beverage caps, edible oil bucket caps, seasoning caps (soy sauce, vinegar, cooking wine, etc.), easy‑open three‑piece cans (beer & beverage aluminum cans), cylindrical composite paper cans for potato chips, puffed snacks and more. Testing Principle The capped packaging container is immersed in water. Pressure is applied inside the container to make internal pressure higher than external water pressure. Keep the pressure stable for a set dwell time. Continuous emerging or overflowing bubbles indicate leakage, which is used to judge sealing performance. Technical requirement for non‑carbonated caps: no air leakage at 200 kPa, no cap detachment at 350 kPa. Executive Standards GB/T 17876‑2010 Packaging containers — Plastic tamper‑evident caps; BB/T 0025‑2004 Plastic tamper‑evident closures; GB/T 17590‑2008 Aluminum easy‑open ends for three‑piece cans; GB/T 10440‑2008 Cylindrical composite cans; YBB00162002‑2015 Aluminum ointment tubes for pharmaceutical use Technical Specifications Pressure Range 0~1 MPa Accuracy ±1%FS Hold Time 0.01s~99.99h Max Sample Size Φ150mm*330mm(H) Air Supply Pressure 0.6~0.8 Mpa Instrument Dimension 400×370×170 mm Power Supply 220V,50Hz Power 100W Weight Main unit:5kg, Water tank:15kg Product Features • Premium Components & Stable Quality. Original imported proportional valve, fast pressurization speed, ultra‑high stability, ultra‑low failure rate, high pressurization efficiency and low noise. • Fully Automatic Operating System. Set pressure and dwell time as required. The instrument automatically completes the whole test process: auto pressurization, pressure holding, auto stop and air reset. • Data Storage & Printing. Equipped with built‑in micro printer and USB data port, supporting PC software for test monitoring and data operation. • GMP Compliant Software. Designed in accordance with GMP Annex 《Computerized System》. It supports audit trail and multi‑level user permission management, satisfying pharmaceutical industry requirements for data traceability. Application Fields Suitable for non‑carbonated PET bottled beverages, canned food & non‑carbonated canned drinks, non‑carbonated glass bottles with aluminum caps, non‑carbonated glass bottles with plastic caps and other food packaging closure sealing inspection. Non-carbonated PET bottle Food can Glass bottle with aluminum cap Glass bottle with plastic cap Conclusion GBM‑S1 cap seal integrity tester is a positive pressure water immersion bubble leak tester for all kinds of bottle caps and easy‑open containers. It adopts microcomputer control and high precision pressure sensor, fully automatic test workflow, with GMP audit trail function, widely used in food, beverage and pharmaceutical packaging closure quality control. Get Quotation for This Unit GBPI Packaging Test Equipment ManufacturerAddress: No.3 Linjiang Road, Xiagang Subdistrict, Huangpu District, Guangzhou, Guangdong, ChinaTel: +86 15820231129 | Official Website: www.gbpitester.com
water vapor permeability test Water Vapor Permeability Analyzer Weight Increase Method W501
water vapor permeability analyzer is to test the water vapor transmission rate (WVTR) of films or sheets materials.
Crush Tester Crush Tester Paper Packaging Test Equipment
Paper Packaging Test Equipment 
synthetic blood penetration tester Mask Synthetic Blood Penetration Tester
It is suitable for the resistance of the mask to the penetration of synthetic blood under different levels of test pressure. The mask material is tested with synthetic blood under continuously applied pressure, and the penetration of synthetic blood on the material is visually checked.
Oxygen Permeability Analyzer Y110 L Oxygen Permeability Analyzer - Coulometric Sensor Method
This product is based on the testing principle of coulometric oxygen sensor, designed and manufactured with reference to ASTM D3985 and other standards. It adopts high-precision imported oxygen sensor with high testing accuracy. It is suitable for oxygen transmission performance testing of films, sheets, papers, packaging and related materials in the fields of food, pharmaceuticals, medical devices, daily chemicals, photovoltaic electronics, etc. It provides wide range and high efficiency oxygen transmission rate testing for high, medium and low oxygen barrier materials.
color measurement device Portable Handheld Spectrophotometers for Plastic Electronic Painting Coating Ink Textile etc Colorimeter Color Difference Meter Tester
Application It is used for accurate color analysis and transmission; it is used for precision color measurement and quality control in plastic electronics, paint ink, textile and garment printing, printing, ceramics, etc.; it can be used for fluorescence sample measurement.
Moisture vapor transmission rate GBPI WVTR Moisture Vapor Transmission Rate Tester
    W201 2.0 Water Vapor Transmission Rate Tester Product Introduction This product is developed, designed and manufactured based on the electrolytic test principle, in accordance with GB/T 21529, ISO15106-3 and other standards. It is used to test the water vapor transmission rate of samples under set temperature and humidity conditions. Suitable for water vapor transmission performance testing of high-barrier materials used in LCD display devices, solar cells, chip packaging, pharmaceuticals, food and other fields. Get a Free Quote Today   Test Principle W201 2.0 Water Vapor Transmission Rate Tester adopts the electrolytic method principle. The pre-processed sample is fixed in the middle of the test chamber, dividing the chamber into high-humidity and low-humidity sides. Humidified nitrogen flows on one side of the film, and dry nitrogen (carrier gas) flows at a fixed rate on the other side. Due to the humidity gradient, water vapor permeates from the high-humidity side to the low-humidity side. The water vapor passing through the sample is carried by the flowing dry nitrogen to the electrolytic sensor, and parameters such as the water vapor transmission rate of the sample are obtained through the electrical signal output by the sensor. Electrolytic Method Working Principle Diagram:             Executive Standards 2025 Edition Chinese Pharmacopoeia <4010 Determination Method of Water Vapor Transmission Rate of Pharmaceutical Packaging Materials>, GB/T 21529-2008, ISO15106-3, DIN 53122-2, YBB00092003-2015, ASTM F3299, JIS K7129-3   Technical Parameters Test Range 0.001~40g/(m²·24h) (Film & Sheet) Resolution 0.0001g/(m²·24h) (Film & Sheet) Temp. Control Range 15~45℃ Temp. Control Accuracy ±0.1℃ Humidity Control Range (5~90)%RH Humidity Control Accuracy ±1%RH Permeation Area 50.24 cm² Sample Size Φ100 mm Sample Thickness ≤3 mm Test Quantity 1 piece Carrier Gas 99.999% Nitrogen (User Provided) Carrier Pressure ≥0.1 MPa Carrier Flow 0~100 mL/min Gas Interface 1/8 inch Metal Tube Dimensions 380×620×385mm Weight 25kg Power 450 W Power Supply AC 220 V, 50 Hz   Product Features Core Technology & Upgraded Operation: High sensitivity, precision and stability of the sensor, capable of testing high-barrier materials in electronics, photovoltaic, solar, display and other fields. Brand new pneumatic control system, automatic fixture locks sample with one key, convenient and labor-saving, with excellent sealing performance. Precise Temperature & Humidity Control: Temperature: Bi-directional automatic control via semiconductor cooling plate, accuracy ±0.1℃. Humidity: Dual-airflow (dry & wet) humidity control method, stable and high precision, accuracy ±1%RH. Strong Expandability: With optional accessories, it can test water vapor transmission rate of packages and containers. Excellent Appearance & Real-time Visual Curve: Built-in 11.6-inch high-resolution color touch screen, clear view, sensitive touch. Fully automatic operation, one-key test, automatic judgment and shutdown. Real-time display of 5 groups of curves (permeation rate-time, temp-time, humidity-time, concentration-time), with preview/hide function. Intelligent OS & Global Certification: Self-developed intelligent OS, modular interface, flexible parameter setting. Designed in accordance with GMP Computerized System, with audit trail and multi-level user authority, meeting pharmaceutical industry data traceability requirements. Customizable test reports, multiple data output formats, electronic signature and online report approval. Professional Calibration & Reliable Data: Our company possesses the National Standard Material Classification Certificate for water vapor transmission rate approved by the State Administration of Quality Supervision, Inspection and Quarantine (GBW(E)130543 / GBW(E)130544). Self-developed national standard materials are used for instrument calibration, ensuring accurate, universal and authoritative test data.   Application Fields Packages & Containers Custom fixtures for pharmaceutical BFS, ointment tubes, infusion tubes. Chip Packaging Materials FR-4, BT resin, PI, ABF film, Al₂O₃ ceramic, metal substrate testing. Solar Cell Barrier Materials Solar backsheet, butyl rubber, ALD Al₂O₃, POE, EVA film testing. Display Field Barrier Materials For LCD high-barrier materials such as epoxy resin film, SiNx passivation film, modified PET Other Materials Ultra-high barrier materials for pharmaceutical, food, daily chemical industries.   Why Choose Us ✓ Professional R&D & Manufacturing We have professional R&D team and complete production line, focusing on physical property testing instruments for more than 20 years, providing reliable and stable testing equipment for global customers. ✓ High Precision & Quality Certification Products comply with international standards, equipped with high-precision sensors and intelligent control system, with national standard material certification and authoritative qualification. ✓ Perfect After-sales & Technical Support Global after-sales service network, timely technical guidance, professional training and lifelong maintenance services to ensure worry-free use. Guangzhou GBPI Packaging Equipment Co., Ltd. | Professional Testing Instrument Manufacturer  
Salt Spray Tester Salt spray test chamber GB-OSH-60
  1. FunFunction Salt spray test chamber is used for the quality inspection and corrosion resistance test of a variety of materials, including metal plating, metal, electronic components, chemical coatings, paint, automobiles, motorcycles, metal ware, screws, springs, magnetic materials, organic and inorganic coating, anodizing, anti-rust oil industry etc. after the surface treatment.   1. ecGTechnical parameters   1. MODEL GB-OSH-60 2. Temperature inside chamber 35℃±1℃/ 50℃±1℃ 3. Temperature of pressure barrel 47℃±1℃/ 63℃±1℃  4. Inner size W600 x H400 x D450mm   5. External size W1080 x H1080 x D650mm 6. Temperature Uniformity ≤±2℃ 7. Uniformity Fluctuation ≤±0.5℃ 8. Salt fog settlement 1~2ml/h.80cm2 9. Compressed air pressure 1.00±0.01kgf/cm² 10. Spray mode Continuous or intermittent spray optional 11. Power supply AC  220V   50Hz   1.5KW a)  Temp. range: RT+10℃ ~ 55℃ (temperature up to 50C, thickening PVC or PP material is recommended ) b) Humid. range: ≥93%R.H c) Controller time shown: 9.9s~9990hrs d) Timer: 0~9999hrs. e) Testing method: Neutral salt spray test (NSS test), acetic acid salt spray test (AASS test), salt spray test (SS test), copper accelerated acetic acid salt spray test method for salt spray test (CASS test) and so on; (For CASS test, we recommend the PP material chamber with high temperature resistance) f) Specimen holder: It can meet the tilt test at 15 ℃ ~ 30 ℃ (two layers); g) Air compressor: V-0.013/12.5(Customer provided); discharge pressure:1.25M; flow amount: 0.13m3/min   1. MMMaterial of machine body a) Salt spray chamber adopts the quality PVC reinforced hard plastic plate, the surface is smooth and anti-aging, anti-corrosion; b) Without any FRP material produced on the surface because of discoloration fibrosis. Plastic structure of the chamber is better to meet strong acid salt spray test under long-term without any damage. c) Cover is imported transparent impact-resistant plate which is convenient to test specimen when test, that can cover and the box with a water seal to prevent leakage of salt spray.   2. AccAccording to CSN, JIS, ASTM standards, can be set to constant temperature control: (a) Brine spray test: NSS (neutral); · Temp. inside chamber: 35 ℃ ± 1 ℃ · Pressure air bucket: 47 ℃ ± 1 ℃ (b) Corrosion resistance test: CASS (copper acceleration), AASS (acid) · Temp. inside chamber: 50 ° C ± 1 ° C · Pressure air bucket: 63 ℃ ± 1 ℃   3. Watwatering system. It adopts the auto watering system, supply water when lack of water. 4. HeaHeating system Test temperature inside the cabinets is heated humidification water jacket, the heater adopts advanced titanium protective tube, built-in nickel-chromium alloy infrared heater core. Heating up fast, uniform temperature distribution; and saves about one half of the power compared to FRP tank jacketed heating. 5. ExeExecutive standard GB/T 2423.17 Basic test procedures for electric and electronic products Ka"- salt spray test methods; GB/T 10125 Corrosion tests in artificial atmospheres – salt spray tests; ASTM B368 Test Method for Copper-Accelerated Acetic Acid-Salt Spray (Fog) Testing (CASS Test); JIS Z2371-2000 Methods of salt spray testing etc. ISO 9227 Corrosion tests in artificial atmospheres (Note: 2 collection device is required, bigger models than ZH-SH-90 (270L) is required; In some versions, it specifies over 400liters is necessary)  ASTM B117-18 Standard Practice for Operating Salt Spray (Fog) Apparatus (Note: 2 collection device is required, bigger models than ZH-SH-90 is required )  
  • Facebook
  • Linkedin
  • Youtube
  • Twitter

Copyright @ 2026 Guangzhou Biaoji Packaging Equipment Co.,Ltd. All Rights Reserved.

Chat now

Inquiry Now

Home

Products

NEWS

contact