Oxygen transmission rate (OTR) is the measurement of the amount of oxygen gas that passes through a substance over a given period. It is mostly carried out on non-porous materials, where the mode of transport is diffusion, but there are a growing number of applications where the transmission rate also depends on flow through apertures of some description.

  • Brand:

    GBPI
  • Item NO.:

    Oxygen Transmission
  • Product Origin:

    Guangzhou China
  • Shipping Port:

    Huangpu Guangzhou
Inquiry now
Product Detail

What affects the OTR of films



Good oxygen barrier is achieved by combining functional layers to create a film with the required barrier, as well as those other properties necessary to produce a serviceable package. For example, EVOH has exceptional OTR properties, but needs moisture barrier and mechanical properties provided by layers that are coextruded or laminated around it.



OTR is most affected by the following factors.



1. Thickness of barrier layer: Generally, the thicker the oxygen barrier-providing layer, the better the barrier. But there are process and cost limitations that restrict the thicknesses that can be realistically produced or successfully utilized.



2. Copolymer ratio, plasticizer content, and polymerization process: All PVdCs (or EVOHs or PVOHs) are not created equal. Properties are compromised during polymer and product development, so that total performance in target applications is optimized. There can be substantial differences in OTR values depending on the selections made. For example, both ASB-X and AXT are PVdC-coated and sealable, but their OTRs are 4.5 cc/100 in2/24 hr and .40 cc/1 00 in2/24 hr, respectively. ASB-X has the poorer OTR, but a broader seal range than AXT.



3. Base film surface compatibility: The physical and chemical characteristics of the base film surface have a major effect on the OTR after metallization, and to a lesser degree, after coating. This is evidenced by Met PET's exceptional barrier, as well as the difference in OTRs between various metallized OPP products (refer to Table 10).


So how to measure the films oxygen transmission rate?



GBPI Overall packaging testing instruments help you find out the answer.

GBPI R&D latest packaging testing equipment for packaging industry.We develope latest Y110 and Y310 Oxygen Permeability Tester for packaging material Oxygen Transmission Rate Testing.



Comply to ASTM standard test methods include:


D3985 Standard Test Method for Oxygen Gas Transmission Rate Through Plastic Film and Sheeting Using a Coulometric Sensor

F1307 Standard Test Method for Oxygen Transmission Rate Through Dry Packages Using a Coulometric Sensor

F1927 Standard Test Method for Determination of Oxygen Gas Transmission Rate, Permeability and Permeance at Controlled Relative Humidity Through Barrier Materials Using a Coulometric Detector

F2622 Standard Test Method for Oxygen Gas Transmission Rate Through Plastic Film and Sheeting Using Various Sensors

Send A Message

Leave us a message, we will get back to you ASAP.

Related Products
Compression Strength Tester BCT (Box Compression Test) Packaging Burst Compression Strength Tester GBN2000Z
This machine is used to test the compression, deformation resistance and stacking of corrugated carton, honeycomb board box and so on.
Film Heat Shrinkage Tester GBK-D1 DIN 53369-1976 Pet Film Heat Shrinkage Tester Thermal Shrinkage Tester For Plastic/PVC /OPS Film
Film Heat Shrinkage Tester tests various heat shrinkage propertiesforthe filmaccording to the principle of air heating (air bath).Suitable for heat shrinkable films which produced with polyethylene, ethylene copolymers and their mixtures, such as beverage labels, bottled bundle packaging, sausage shrinkage packaging, outer film of daily chemical products, outer film of cigarette boxes, etc. It is a device that can accurately and quantitatively measure the thermal shrinkage force, cold shrinkage force, shrinkage rate, shrinkage time and other properties of plastic films during thermal shrinkage.
Cap Torque Analyzers Torque Testing Equipment HP-200
Torque tester HP-200 is a testing instrument for bottle cap locking and opening based on ASTM and GB standard requirements and market demand developed and manufactured by GBPI R&D team. For bottle packaging products, nozzle packaging products and tube packaging products, the size of the cap opening torque is one of the key control parameters, which has a great impact on the intermediate transportation and final consumption of the product.It is suitable for measuring the size of the locking and opening torque of bottle products, and is an indispensable test equipment in the production process.
 Disk Stripping Tester Gx-B2 Disk Stripping Tester
To test the ink layer bonding strength of printed (intaglio) plastic film, composite film, cellophane and so on; test the layer bonding status formed by vacuum coating, surface coating and composite technology etc. It meets the GB/T 7707-2008 standard The intaglio prints for decorating.
Spout bag packaging machine Single-Channel Linear Mode Corner-Spout Sealing Machine
Product Introduction This professional machine is designed for automatic tube insertion and heat-sealing of straws and bags. It is suitable for straws of various diameters, lengths, and models, making it the preferred automated equipment for packaging bags such as laundry detergent spout side bags, beverage/juice spout bags, oil/grease spout bags, and inclined-mouth outdoor foldable water bags. It can be customized to connect with filling production lines.
Vertical Heat Seal Tester Vertical Heat Seal Tester GBB-C
Product Introduction GBB-C vertical heat seal tester can accurately measure the heat sealing temperature, heat sealing time, heat sealing pressure, and other heat sealing performance parameters of plastic packaging vertical bags, paper-plastic composite vertical bags and metal composite vertical bags(boxes). The heat sealing performance of samples of different materials are different. And the best heat sealing conditions can be accurately obtained through the determination of their heat sealing performance parameters.   Testing Principle Put the sample on the lower tray of the instrument, adjust the appropriate height according to the size of the sample, set a certain sealing temperature, time and pressure as required, and start the instrument with one key. The fixture on the instrument will heat seal the sample according to the setting parameters. Under the manual state, step on the foot switch, and the heat sealing knife is pressed. The heat sealing time is determined by the value set by the time control. In the automatic state, the upper and lower heat sealing knives of the heat sealer will automatically heat seal repeatedly according to the set time. Standards ASTM F 2029 Specifications Item  Technical Parameters Temperature Range Room temperature ~ 250℃ Temperature Control Accuracy ±1℃ Hot Sealing Time 0.1s ~ 99.99 h Hot Sealing Pressure (0~1) MPa Hot Sealing Surface Upper and lower sealing knives: 300×5.5 mm, smooth; lower sealing bar with silicon pad Operation Mode Two modes: automatic and manual, with external cylinder Gas Source Compressed air Overall Dimensions 730(L) mm×400(B) mm×535(H) mm Weight 33.8kg Power 1200 W Power Supply AC 220V, 50Hz     Characteristics u High progress imported quality sensor, quality assurance Original imported temperature sensor, wide temperature control range, high sensitivity, temperature control accuracy of ± 1 ℃, it has ultra-high stability and ultra-low failure rate. u Independent control of heat sealing temperature The rear of the heat sealing knife is equipped with a temperature sensor, and the temperature control of the inner and outer sealing knives is independent and set separately. u Personalized test selection Manual testing and automatic testing are free to choose. The automatic mode is time-saving and convenient, and the repeatability is fully automatic for heat-sealing the sample; the manual mode is equipped with a suitable foot switch, step on the foot switch, the heat sealing knife is pressed, and the safety protection is easy to operate. u New air drive system The drive system consists of a pressure gauge, a pressure regulating valve, and a cylinder. After the compressed air is introduced, the pressure is adjusted through the pressure valve, the air pressure can be accurately locked, and the heat sealing clamp is pneumatically driven, which is convenient and efficient. u Wider range of customized services The anti-sticking function of the heat sealing knife can be upgraded as needed, experience upgrade, and it is more intuitive and convenient to determine the best heat sealing conditions. The shape, size and smoothness of the sealing knife heat cover can be customized to meet different scientific research needs.   Application     Plastic stand up pouch Paper plastic stand up pouch     Aluminized stand up pouch Milk Boxes  
Vacuum Decay Leak Detection Tester Dual Pressure Methods Vacuum Decay Leak Detection Tester AUTO GBM-L2
Introduction AUTO GBM-L2 Dual-Pressure Methods Vacuum Decay Leak Detection Tester adopts the test principle of vacuum decay method/pressure decay to detect micro-leakage of finished packaging. It can be applied to packaging systems composed of vials, ampoules, Leakage detection of pre-filled needles, eye drop bottles, HDPE bottles, infusion bottles/bags and other pharmaceutical packaging, food packaging, and chemical industry packaging.   Test principle The host is connected to a sealed test chamber customized according to the sample. When performing the vacuum decay method test, the instrument evacuates the test chamber, and a pressure difference is formed inside and outside the sample. Under the action of the pressure, the gas/liquid in the sample enters the test chamber through the leak hole. The main engine uses the absolute pressure sensor and the differential pressure sensor to monitor the pressure change in the chamber to judge whether the sample leaks. When performing the pressure decay method test, the instrument fills the test chamber with a predetermined air pressure, and the gas in the test chamber enters the sample through the leak hole. The host uses absolute pressure sensors and differential pressure sensors to monitor the pressure changes in the chamber to determine whether the sample is leaking.   Standard ASTM F2338-2009(2013),  YY-T 0681.18-2020,  USP<1207.2>, ASTM F2095   Specification Item Parameters Absolute Pressure Testing Range (0 - 300) kPa Differential Pressure Testing Range (-2 - 2) kPa Detection Sensitivity 1 - 3 μm Balancing/Testing Time 1 - 3600 s Vacuum Purge Time 1 - 3600 s Set Flow Rate 0 - 3 mL/min Testing System Dual Sensor Technology/Dual Cycle Testing Testing Chamber Customized according to the sample Applicable Products Vials, Ampoules, Prefilled Syringes, Infusion Bottles/Bags, etc. Detection Principle Vacuum Decay Method/Pressure Decay Method Dimensions of the Main Unit 495 mm455 mm280 mm Ambient Temperature 20℃ - 25℃ Relative Humidity 40% - 60% Working Power Supply AC 220V, 50HZ   Features u Dual-Pressure Methods, to help solve testing difficulties The double combination of vacuum decay method and pressure decay method solves the problem of easy misjudgment and false negative for freeze-dried powder injections containing vacuum in the bottle using a single vacuum decay method. Based on dual-sensor and dual-circulation system technology, high-quality absolute pressure sensor and differential pressure sensor, with an accuracy of 0.1% FS, can effectively detect large and small leaks, accurately calculate the leak hole diameter, and give a pass or fail judgment.   The instrument has low sensitivity and good test repeatability For rigid samples, the detection sensitivity is as low as 1 μm, and the test repeatability is as low as 0.8%. The instrument has stable performance, low noise and good repeatability. u Imported brand accessories, excellent performance Imported brand vacuum pump, pumping rate up to 3 L/s, noise as low as 50 DB, high ultimate vacuum, convenient oil level detection and replacement. The imported gas mass flow controller can simulate micro-leaks arbitrarily, with a resolution of 0.001 mL/min, which provides a reliable guarantee for the method verification of instrument sensitivity. u Large size touch screen, intelligent operation Color 7-inch touch screen, clear view, sensitive touch, easy to operate. Equipped with a micro-printer, USB data interface, and supports PC software measurement and control operation. The test software is designed according to the GMP appendix "Computerized System". It has an audit trail function and multi-level authority settings for users, which can meet the needs of the pharmaceutical industry for data traceability. u Personalized customization to meet the needs of different samples For different test samples, it supports customization of suitable test chambers to meet the needs of different tests. For the same type of samples, it supports customized nesting mode, which can realize the sharing of a test chamber for samples of various specifications.   Application       Freeze-dried powder injection Injection Prefill needle       Eye drops Plastic Ampoule BFS Infusion bags   Factory configuration Standard Host machine, vacuum pump, test chamber and 3 sets of yin and yang control (customized as required), 11-inch touch panel, professional software (GMP) Optional Imported gas flow meters, air compressors, printers, calibration certificates  
coefficient of friction tester New advanced 0.01~0.999 film packaging COF GM-6 coefficient of friction tester GM-6
Coefficient of friction testers is used to test the coefficient of frictionof plastic film, thin sheet, paper and so on, widely used in packaging industry, film-making companies and packaging material inspection agencies.
drying oven DHG-9030A Drying Oven
It is used to dry, bake, melt and sterilize test sample, widely used in industrial and mining enterprises, laboratory, research institute, inspection agency, college and so on.
Professional SGW-810 Light Transmittance and Haze Tester Haze ASTM D1003 supplier SGW-810 Light Transmittance and Haze Tester Haze ASTM D1003
Application Use for test the light transmittance and haze degree of all transparent and semi-transparent parallel plane samples (plastic plate, sheets etc), and turbidity or clarity of liquid samples (water, drinks etc), used in the industries of plastics, membrane, coatings and paints, printing ink, research institute and so on.
Electronic Tensile Tester Electronic Digital Tensile Tester Machine GBL-L
GBL-L Electronic Digital Tensile Tester Machine apply to test the tensile strength, peeling strength, heat sealing strength and tearing strength of plastic film, composite film, tape, soft packaging material, rubber sheets, paper, non-woven fabrics and other packaging materials, widely used in industries of membrane, packaging, pharmaceuticals, food industries, inspection agency, research institute, college and so on.
Xenon arc lamp aging test chamber Xenon arc lamp aging test chamber GB-OXD-15P
  1.Profile Xenon lamp aging test chamber simulates the full spectrum lamp with Xenon arc lamp to reappear the destructive wave. It serves for the environmental simulation and accelerated test for research and development, product development and quality control. Besides, the chamber also applies to the choice of new material, weathering test after composition of material and improvement for the current material. It simulate different environment, and show the material changes under the explosion of sunlight.   The chamber meets the standard: GB/T16585-1996 , GB14522-93 , GB/T16422.3-97, ASTM D2565 and so on. The Chamber is to determine the color fastness, aging resistance of textiles, plastics, coatings, rubber products or other materials by objecting to the simulated conditions of nature weather (sun, rain, temperature and humidity, etc.).     Technical parameters   2.Material of construction u Full spectrum lamp u Optional filter system u Water spraying function u Humidity control u Temp. control system in the chamber u Sample fixed hold of irregular shape u USA imported xenon arc lamp u Easy installation and operation, seldom daily maintainance. u Service life time deepens on the irradiance level, usually 1600hrs. It’s easy to replace the lamp, with filter of long service life time to ensure the necessary spectrum. 3.Technical parameters Model No., equipment name GB-OXD-15P Xenon aging test chamber Interior sizes   W500×D500×H600mm  Exterior sizes W1050×D1050×H1750mm (or so) Temperature range 0℃~80℃ Controller imported programmable 7inch touch screen Machine components material inner and outer 304# stainless steel Sample holder Aluminum alloy frame base Protection device residual-current circuit breaker (RCCB) to control the warning for loop overload, thermal protection and water shortage protection. Temp. deflection ±2℃  (without lighting) Humidity range 30%~98%R.H Humid. deflection ±2.5%R.H(Humid.≥75%R.H); ±3%R.H(Humid.≤75%R.H) without lighting Light source imported full spectrum xenon arc lamp(average useful life 1600hrs) Raining time 1~9999min (adjustable) Raining period 1~240min, interval(cut)adjustable lamp power Test period for Temp., irradiation, condensation, spray can be adjustable Lamp 1.8KW Wave length range 290-800nm heating power (or so) 4.0KW humidification (or so) 2.0KW Light irradiance 1200w/m2 Distance between arc center and sample holder: 350~380mm Revolving speed of sample holder ≥1r/min  water spray period a. spray time: 0~99h59min (Continuing or adjustable) b. stop time: 0~99h59min, (Continuing or adjustable)   lighting time Continuing programming control available black panel temp. 85±3℃ cooling method Mechanical wind cooling; Room temp. less than 26℃ is recommend, relative humid: ≤85%R.H; humid. and temp. tested after 2 hours under idle condition. 4.Temperature & humidity running control system controller imported programmable 7inch touch screen precision range set precision: temp. ±0.1℃, humid: ±2%R.H, indicated precision: temp.±0.1℃,humid.: ±1%R.H temp. & humid. sensor Platinum Resistance(PT100Ω/MV) black panel temp. double-metal black panel temp. thermometer water-supplying system auto-control humidication water-supplying, Xenon arc lamp with cycling cooling water circulation system low noise heat-resistance conditioning motor, multi-blade centrifugal wind wheel control system mainly consists of operation panel, central controller, kinds of key-pressing sw., status indicating lamp, excution electric device etc.. 5.Structure section of machine body The chamber consists of several section: chamber body, control system, refrigeration system, heating system, humidation system, wind system, raining system, lighting system and so on. Chamber body a. With integrated structure, the chamber consists of up left part as working room, up right part as electric controller which is convenient to control, down part as compressor cooling group, sample holder rotation device, Xenon lamp condensation water box, water pump and other executive devices. b. Inner wall of chamber adopts international SUS304# material. c. Temp. insulation material is polyurethane foam and ultra-fine fibre glass, with good temp. insulation result, no frost and condensation on the external surface of chamber. d. condensate water outfall set at the bottom of chamber e. Environmental heat-resistance silicon sealing tape as the material of door frame. f. Viewing window with eye-protective film on its surface to protect eyes from being injured by Xenon lamp. external chamber body a. Seal of door adopts the double-layer of refined silicone rubber with reliable sealing effect and no aging or hardening phenomenon under high or low temperature. b. Single door (embedded handle); c. Viewing window, antifrost device and lamp equipped on the door viewing window Size:25 cm W × 30 cm H;equipped with Anti-radiation hollow glass 6.Electric control section of chamber a. As the core part of chamber b. Air pressure switch as the main switch to control the main circuit; c. Safety measures for electric section: it warns and cut electricity automatically after tested the action from following protection devices: a) overheat protection in working room b) lockage of phase, leakage protection c) overcurrent protection of motor d) overpressure/overload protection of cooling machine e) short out/overload protection of heater, humidifer f) fusing protection of fuse 7.Working section of chamber Condensation section of compressor. a.Cooling system: as the core part of cooling system, we adopt one set of compressor of Tecumseh from France in this case to ensure the cooling requirement in the working room. b.For adjustment technology and design of cooling system, we take an efficiency processing way to ensure the adjustment for the cooling amount and consumption of cooling system under the normal running, to make the failure rate down to the economical statue. c.Cooling evaporator: it locates in interlayer at one side of chamber which ventilate by force from blast motor to exchange heat fast. d.Cooling method of cooling system: forced air cooling Cooling refrigerant:Environmental R404a; Heating system a. Heating method: heating directly in the chamber; b. Military level stainless steel heating tube used, with fast and stable heating to keep temperature in the working room from rapid change. It with corrosion resistance, anti-high-low temperature, no leakage and other advantages. c. With SSR (solid relay)output control, without noise, reliable working, long service life time, fast switching, low interference from outside, and easy operation etc.. Rain system.   it consists of nozzle, solenoid valve, water-supplying and connecting pipe. Lighting system. It consists of xenon lamp, lamp cover, lamp contactor and other controlling parts. Energy compensation is got by adjusting samples distance, pressure and current. Wind system  It locates in the interlayer at the back of chamber, there are heater, fan blade, evaporator, PT100 temperature samples sensor etc.. when wind machine running, the air is intaken to the channel from working room, and blow out from the bottom after cooled; the air exchanged in the working room with samples is intaken again to the channel and mix; after several circulation, it will reach the purposed temperature, and ensure the high index of temp. and humid in the chamber at the same time. Cooling dehumidification system take the compressor of world brand Tecumseh from France to keep constant temperature, decrease the humidity in the working room and cool the xenon lamp. Humidification Steam generator: to generate steam from water Water level control: control the water inlet by solenoid valve, and water level by liquid level switch to provide the signal for water-supply and warning. Air circulation section Cycling channel and winding machine inside the chamber, it uses the high efficiency cooling machine and energy adjusting system, efficiency heat exchange to reach the aim of temperature change, which also improves the airflow and heat exchange between airflow, heating and humidification, as a result, it improves the humidity uniformity in the working room. 8. Enclosured files: operation manual, warranty card 9. Machine running requirements Temp. 5℃~+32℃ Humidity ≤85% Power supply AC220(±10%)V/50HZ    10. Core components parts Remark: replacement of some small parts of the same quality is possible because of material shortage.    