packaging testing equipment Water Vapor Permeation Tester
Products
Home /

Flexible Packaging Testing Service

/

Testing Items

/

oxygen transmission rate test

/EVOH Barrier film oxygen transmission rate testing

EVOH Barrier film oxygen transmission rate testing

Oxygen transmission rate (OTR) is the measurement of the amount of oxygen gas that passes through a substance over a given period. It is mostly carried out on non-porous materials, where the mode of transport is diffusion, but there are a growing number of applications where the transmission rate also depends on flow through apertures of some description.

  • Brand:

    GBPI
  • Item NO.:

    Oxygen Transmission
  • Product Origin:

    Guangzhou China
  • Shipping Port:

    Huangpu Guangzhou
Inquiry now
Product Detail

What affects the OTR of films



Good oxygen barrier is achieved by combining functional layers to create a film with the required barrier, as well as those other properties necessary to produce a serviceable package. For example, EVOH has exceptional OTR properties, but needs moisture barrier and mechanical properties provided by layers that are coextruded or laminated around it.



OTR is most affected by the following factors.



1. Thickness of barrier layer: Generally, the thicker the oxygen barrier-providing layer, the better the barrier. But there are process and cost limitations that restrict the thicknesses that can be realistically produced or successfully utilized.



2. Copolymer ratio, plasticizer content, and polymerization process: All PVdCs (or EVOHs or PVOHs) are not created equal. Properties are compromised during polymer and product development, so that total performance in target applications is optimized. There can be substantial differences in OTR values depending on the selections made. For example, both ASB-X and AXT are PVdC-coated and sealable, but their OTRs are 4.5 cc/100 in2/24 hr and .40 cc/1 00 in2/24 hr, respectively. ASB-X has the poorer OTR, but a broader seal range than AXT.



3. Base film surface compatibility: The physical and chemical characteristics of the base film surface have a major effect on the OTR after metallization, and to a lesser degree, after coating. This is evidenced by Met PET's exceptional barrier, as well as the difference in OTRs between various metallized OPP products (refer to Table 10).


So how to measure the films oxygen transmission rate?



GBPI Overall packaging testing instruments help you find out the answer.

GBPI R&D latest packaging testing equipment for packaging industry.We develope latest Y110 and Y310 Oxygen Permeability Tester for packaging material Oxygen Transmission Rate Testing.



Comply to ASTM standard test methods include:


D3985 Standard Test Method for Oxygen Gas Transmission Rate Through Plastic Film and Sheeting Using a Coulometric Sensor

F1307 Standard Test Method for Oxygen Transmission Rate Through Dry Packages Using a Coulometric Sensor

F1927 Standard Test Method for Determination of Oxygen Gas Transmission Rate, Permeability and Permeance at Controlled Relative Humidity Through Barrier Materials Using a Coulometric Detector

F2622 Standard Test Method for Oxygen Gas Transmission Rate Through Plastic Film and Sheeting Using Various Sensors

Send A Message

Leave us a message, we will get back to you ASAP.

Related Products
DSC Tester DSC100A DSC Testing Lab Differential Scanning Calorimeter
Product introduction:        DSC is the company's highest precision differential. The sensor is made of imported e-couple with high sensitivity.Signal acquisition circuit shielding protection, strong anti-interference, high baseline stability. The DSC is a touch screen type, which can be used for glass transition temperature test, phase transition test, melting and enthalpy test, product stability and oxidation induction period test.Wide range of application   Technical parameters: 1. Temperature range:Room temperature ~550 ℃ air cooling 2. Temperature resolution: 0.01℃ 3. Temperature fluctuation:±0.1℃ 4. Temperature repeatability:±0.1℃ 5. Heating rate: 0.1~100℃/min 6. Constant temperature time: program setting ≤ 24h 7. Temperature control mode: heating, constant temperature, 8. DSC range: 0~±600mW 9. DSC resolution: 0.01uW 10. DSC accuracy: 0.001mW 11. Working power supply: Ac220vv50 Hz or customized 12. Atmosphere control gas: nitrogen, oxygen (instrument automatic switch) 13. Gas flow: 0-300mllmin 14. Gas pressure: 0.2MPa 15. Display mode: 24 bit color, 7 inch LCD touch screen display 16. Data interface: standard USB interface 17. Parameter standard: With reference materials (indium, tin), users can adjust the temperature by themselves 18. The upper computer is a three in one operation software, which is also suitable for thermogravimetry and synchronous instruments. 19. The instrument has several groups of thermocouples, one for sample temperature, one for furnace body temperature and one for internal environment temperature Technical features: 1. Industrial level 7-inch touch screen, display information rich. 2. New metal furnace structure, better baseline and higher precision.Indirect conduction mode is adopted in heating, which has high uniformity and stability, and reduces pulse radiation, which is better than traditional heating mode. 3. USB communication interface, strong versatility, reliable communication, support self recovery connection function. 4. Automatic switching of two-way atmosphere flow, fast switching speed and short stable time.At the same time, a protective gas input is added. 5. The software is simple and easy to operate.
 Face Mask Particulate Filtration Efficiency Tester Face Mask Particulate Filtration Efficiency Tester
GBPI offers mask testing machines for surgical face masks, N95 masks, Melt-blown fabric. BFE Tester, PFE Tester, N95 Tester, Melt-blown fabric Tester
Bacterial Filtration Efficiency Mask Bacterial Filtration Efficiency (BFE) Tester - GB-XF1000
It is used to test the percentage of materials containing bacteria suspended particles at the specified flow rate.
ISO 2248 Incline Impact Testers For Packages Packaging Impact Strength Test ISTA 6 Packaging Test Bundle
The Inclined Impact tester is simulated the impact strength of packaging in the real circumstance of transport such as handling, stacking of shelves, sliding, loading , transportation of products. This product is also can supply as the test machine to scientific research institution, college, packaging technique test centre, packaging material manufacture and foreign trade or transport department.
Adhesive Tape Roller Pressing Machine Plastic Film Adhesive Tape Rolling Pressing Machine
The Adhesive Tape Roller GX-Y2 is suitable for plastic film and cellophane decorative prints (including composite film prints) produced by gravure printing process. It is also used to test the adhesion state of the surface layer formed by vacuum coating, surface coating, compounding and other related processes.
medical sterilized boiler ZM-100 inverted pressure sterilized boiler
ZM-100 Inverted pressure sterilizer boiler is used for sterilization and high temperature test of packaging materials (including adhesives and printing ink) in the industries of packaging, plastic films, food, medical units, inspection agency, research institute etc.
Oxygen Gas Permeability Tester Coulometric Sensor Method Oxygen Permeability Analyzer Y310L
Introduction This product is designed and manufactured based on the coulometric sensor method and conforms to GB/T 19789、ASTM D3985.This instrument can be used to measure the oxygen transmission rate of barrier materials with high and medium barrier properties with high accuracy and high efficiency.Y310Lis applicable to the determination of oxygen permeability of plastic films, sheeting, paper, and other packaging materials used in food, pharmaceutical, medical apparatus, consumer products, photovoltaic and electronic industries, etc.
Optical Properties Testing P60 Standard Light Source Optical Properties Testing
P60 Standard Light Source Used for color observation, color contrast and color matching in a wide range of industries of printing, paints, printing ink, plastics, dyeing and so on.
Battery Diaphragm Gas Permeability Tester Battery Diaphragm Gas Permeability Tester N600E
  Introduction Battery Diaphragm Gas Permeability Tester N600E is designed and developed according to GB/T 36363-2018 and other standards. It adopts the test principle of differential pressure method and is professionally used for testing the air permeability of battery separators, breathable membranes and related polymer materials. Test principle In the environment of test temperature, humidity and normal pressure, under the pressure of 1.21kPa applied by the test instrument, the time required for 100mL air to pass through the diaphragm with an area of 6.45 cm2.   Standard ISO 5636-5, TAPPI T460, GB/T 36363 Specification Test range 60~12000 s/100mL Resolution 0.1 s/100mL Pressure range 0~3 KPa Pressure resolution 0.001 kPa Test area 6.45cm2 Sample size >50 mm×50 mm Instrument Size 450 mm×400 mm×300 mm Power 100W Power supply 110~250 VAC, 50~60 Hz   Features     The pressure difference of the instrument is adjustable in the range of 0~3 kPa, with an accuracy of 0.001 kPa, which fully meets the test pressure difference requirements of different methods;     The instrument supports s/100mL and um/(Pa.s) multi-unit display.     The test range can be customized according to different sample requirements.     The host is equipped with a color touch screen, no need for an external computer, and the air permeability of the sample can be observed in real time; Built-in micro-printer, which can print test report in real time; Application   Lithium Ion Battery Polyolefin separator for lithium ion battery, coated polyolefin separator for lithium ion battery or separator for lithium ion battery using other materials  
Residual Solvents Testing Flexographic Printing Residual Solvents in Packaging Materials
The identification and quantitation of residual printing solvents in synthetic packaging materials are very important for the material packaging suppliers, the printers and the packaging users of food and pharmaceutical products.
Atmosphere Refrigerator AUTO GQ900 Modified Atmosphere Refrigerator
AUTO GQ-900 Modified Atmosphere Refrigerator is mainly for a variety of fruits, vegetables, flowers, seedlings, etc. on the market for storage and preservation tests, through microelectronics technology to automatically control the concentration of oxygen, nitrogen, carbon dioxide, ethylene in the box, as well as control temperature, humidity conditions to achieve the preservation effect, is a microorganism, environmental protection, food production, universities, scientific research institutions and other units indispensable ideal equipment.
  • Facebook
  • Linkedin
  • Youtube
  • Twitter

Copyright @ 2025 Guangzhou Biaoji Packaging Equipment Co.,Ltd. All Rights Reserved.

Chat now

Inquiry Now

Home

Products

NEWS

contact