packaging testing equipment Water Vapor Permeation Tester
Products
Home /

Physical Property Test Equipment

/

Coefficient of Friction Tester

/GM-1 0-10N plastic film packaging coefficient of friction tester

GM-1 0-10N plastic film packaging coefficient of friction tester

The coefficient of friction tester is used to test the coefficient of frictionof plastic film, thin sheet, paper and so on, widely used in packaging industry, film-making companies and packaging material inspection agencies.

  • Brand:

    GBPI
  • Item NO.:

    GM-1
  • Payment:

    TT
  • Product Origin:

    China
  • Lead Time:

    around 7 working days
Inquiry now
Product Detail



Introduction

The coefficient of friction tester GM-1 is a measuring instrument developed and manufactured by the Guangzhou Biaoji R&D team based on various test standards of GB, ISO, ASTM and market demand. The measured friction coefficient determines the smoothness and opening difficulty of the film. and uniformity can be accurately determined, so as to correctly guide the production.

It is suitable for measuring the static friction coefficient, dynamic friction coefficient and peel strength of plastic films, composite films, aluminum foils, aluminized films, plates, rubber, ceramics and other materials when sliding.

Test Principle

Use a clamp to clamp the strip test sample, and wrap the slider with the sample to be tested, and then place the slider on the hanging hole of the sensor. Under a certain contact pressure, the conveyor belt is driven by the motor to move the force sensor. , that is, to move the two test surfaces relative to each other. The force signal measured by the force sensor is amplified by the integrator and sent to the recorder, and the kinetic friction coefficient and the static friction coefficient are recorded respectively.

 

 

Standard

GB 10006、ISO 8295、TAPPI T816

Specification

Item

Technical parameter

COF test range

0.001~0.999

Resolution

0.001

Measurement accuracy

±0.5FS

Force range

0~9.8 N

Sliding speed

100150500 mm/min

Stroke

100 mm±5 mm

Sample thickness

≤2 mm

Slider size

63 mm×63 mm

Slider Weight

200 g±2 g

Work platform size

200 mm×470 mm

Instrument size

470 mm×350 mm×220 mm

Power

100 W

Power supply

AC 220 V50 Hz

Weight

12.5 kg

 

 

Feature

 Instrument is stable, reliable and easy to maintain

 Intelligent operating system

 Laboratory intelligent Iot platform  


Application

 

 

Film

Suitable for static friction coefficient and dynamic friction coefficient test of plastic film and thin film  

 

Paper

 Suitable for dynamic and static friction coefficient test of paper and cardboard

 

 

Textiles, non-woven fabrics, woven bags

 

Suitable for testing static friction coefficient and dynamic friction coefficient of textile, non-woven fabric and woven bag

 

Aluminum foil, aluminum foil composite film, metal products

 

Suitable for testing static friction coefficient and dynamic friction coefficient of aluminum foil, aluminum foil composite film and metal products  

 

Printing product

It is suitable for static friction coefficient and dynamic friction coefficient test of printed matter



Send A Message

Leave us a message, we will get back to you ASAP.

Related Products
coefficient of friction tester New advanced 0.01~0.999 film packaging COF GM-6 coefficient of friction tester GM-6
Coefficient of friction testers is used to test the coefficient of frictionof plastic film, thin sheet, paper and so on, widely used in packaging industry, film-making companies and packaging material inspection agencies.
Inclined Plane Friction Tester Inclined Surface Coefficient Of Friction Tester
GM-F1 Inclined Coefficient of Friction Tester is expert applicable to the resolve of stationary coefficients of paper board, friction of paper, sheets, plastic films, convey belts and additional substances. By challenging the frictional possessions of substances, the open presentation of packages, packing rapidity of packers and additional indexes could be regulated to meet necessities for production.Different functions from other coefficient friction testers  (cof)    
COF tester GM-4 Coefficient of Friction Tester
  The coefficient of friction tester GM-4 is a measuring instrument developed and manufactured by the Guangzhou Biaoji R&D team based on various test standards of GB, ISO, ASTM and market demand. The measured friction coefficient determines the smoothness and opening difficulty of the film. and uniformity can be accurately determined, so as to correctly guide the production. It is suitable for measuring the static friction coefficient, dynamic friction coefficient and peel strength of plastic films, composite films, aluminum foils, aluminized films, plates, rubber, ceramics and other materials when sliding.        
WVTR Testing Equipment Moisture vapor transmission rate (MVTR)-AUTO W806
  product description This product is based on the principle of water vapor transmission test by cup method and designed and manufactured with reference to ASTM E96, standard, providing a wide range and high efficiency water vapor transmission rate test for low, medium and high water vapor barrier materials.It is suitable for water vapor transmission performance testing of films, sheets, papers, fabrics, nonwovens and related materials in the fields of food, pharmaceuticals, medical devices, daily chemicals, etc.    
Gas Permeation Tester Gas Permeability Analyzer for Testing Packaging Material GTR - N530
GBPI Gas Permeability Tester N530 demonstrate how to test gas volumn pass through your packaging material
Air Transmission Tester Air Permeability Analyzer for Textile- N900
N900 Air Permeability Analyzer to test the air permeability of many textile, including technical fabric, non-woven and breathable textile products.  
Professional Packaging lab equipment high accuracy barrier film water vapor permeability analyzer moisture vapour transmission rate supplier Packaging lab equipment high accuracy barrier film water vapor permeability analyzer moisture vapour transmission rate
Application W413 2.0 water vapor permeability tester is designed to test the water vapor transmission rate (WVTR) of films or sheets materials.  
Salt Spray Tester Salt spray test chamber GB-OSH-60
  1. FunFunction Salt spray test chamber is used for the quality inspection and corrosion resistance test of a variety of materials, including metal plating, metal, electronic components, chemical coatings, paint, automobiles, motorcycles, metal ware, screws, springs, magnetic materials, organic and inorganic coating, anodizing, anti-rust oil industry etc. after the surface treatment.   1. ecGTechnical parameters   1. MODEL GB-OSH-60 2. Temperature inside chamber 35℃±1℃/ 50℃±1℃ 3. Temperature of pressure barrel 47℃±1℃/ 63℃±1℃  4. Inner size W600 x H400 x D450mm   5. External size W1080 x H1080 x D650mm 6. Temperature Uniformity ≤±2℃ 7. Uniformity Fluctuation ≤±0.5℃ 8. Salt fog settlement 1~2ml/h.80cm2 9. Compressed air pressure 1.00±0.01kgf/cm² 10. Spray mode Continuous or intermittent spray optional 11. Power supply AC  220V   50Hz   1.5KW a)  Temp. range: RT+10℃ ~ 55℃ (temperature up to 50C, thickening PVC or PP material is recommended ) b) Humid. range: ≥93%R.H c) Controller time shown: 9.9s~9990hrs d) Timer: 0~9999hrs. e) Testing method: Neutral salt spray test (NSS test), acetic acid salt spray test (AASS test), salt spray test (SS test), copper accelerated acetic acid salt spray test method for salt spray test (CASS test) and so on; (For CASS test, we recommend the PP material chamber with high temperature resistance) f) Specimen holder: It can meet the tilt test at 15 ℃ ~ 30 ℃ (two layers); g) Air compressor: V-0.013/12.5(Customer provided); discharge pressure:1.25M; flow amount: 0.13m3/min   1. MMMaterial of machine body a) Salt spray chamber adopts the quality PVC reinforced hard plastic plate, the surface is smooth and anti-aging, anti-corrosion; b) Without any FRP material produced on the surface because of discoloration fibrosis. Plastic structure of the chamber is better to meet strong acid salt spray test under long-term without any damage. c) Cover is imported transparent impact-resistant plate which is convenient to test specimen when test, that can cover and the box with a water seal to prevent leakage of salt spray.   2. AccAccording to CSN, JIS, ASTM standards, can be set to constant temperature control: (a) Brine spray test: NSS (neutral); · Temp. inside chamber: 35 ℃ ± 1 ℃ · Pressure air bucket: 47 ℃ ± 1 ℃ (b) Corrosion resistance test: CASS (copper acceleration), AASS (acid) · Temp. inside chamber: 50 ° C ± 1 ° C · Pressure air bucket: 63 ℃ ± 1 ℃   3. Watwatering system. It adopts the auto watering system, supply water when lack of water. 4. HeaHeating system Test temperature inside the cabinets is heated humidification water jacket, the heater adopts advanced titanium protective tube, built-in nickel-chromium alloy infrared heater core. Heating up fast, uniform temperature distribution; and saves about one half of the power compared to FRP tank jacketed heating. 5. ExeExecutive standard GB/T 2423.17 Basic test procedures for electric and electronic products Ka"- salt spray test methods; GB/T 10125 Corrosion tests in artificial atmospheres – salt spray tests; ASTM B368 Test Method for Copper-Accelerated Acetic Acid-Salt Spray (Fog) Testing (CASS Test); JIS Z2371-2000 Methods of salt spray testing etc. ISO 9227 Corrosion tests in artificial atmospheres (Note: 2 collection device is required, bigger models than ZH-SH-90 (270L) is required; In some versions, it specifies over 400liters is necessary)  ASTM B117-18 Standard Practice for Operating Salt Spray (Fog) Apparatus (Note: 2 collection device is required, bigger models than ZH-SH-90 is required )  
Moisture vapor transmission rate GBPI WVTR Moisture Vapor Transmission Rate Tester
    W201 2.0 Water Vapor Transmission Rate Tester Product Introduction This product is developed, designed and manufactured based on the electrolytic test principle, in accordance with GB/T 21529, ISO15106-3 and other standards. It is used to test the water vapor transmission rate of samples under set temperature and humidity conditions. Suitable for water vapor transmission performance testing of high-barrier materials used in LCD display devices, solar cells, chip packaging, pharmaceuticals, food and other fields. Get a Free Quote Today   Test Principle W201 2.0 Water Vapor Transmission Rate Tester adopts the electrolytic method principle. The pre-processed sample is fixed in the middle of the test chamber, dividing the chamber into high-humidity and low-humidity sides. Humidified nitrogen flows on one side of the film, and dry nitrogen (carrier gas) flows at a fixed rate on the other side. Due to the humidity gradient, water vapor permeates from the high-humidity side to the low-humidity side. The water vapor passing through the sample is carried by the flowing dry nitrogen to the electrolytic sensor, and parameters such as the water vapor transmission rate of the sample are obtained through the electrical signal output by the sensor. Electrolytic Method Working Principle Diagram:             Executive Standards 2025 Edition Chinese Pharmacopoeia <4010 Determination Method of Water Vapor Transmission Rate of Pharmaceutical Packaging Materials>, GB/T 21529-2008, ISO15106-3, DIN 53122-2, YBB00092003-2015, ASTM F3299, JIS K7129-3   Technical Parameters Test Range 0.001~40g/(m²·24h) (Film & Sheet) Resolution 0.0001g/(m²·24h) (Film & Sheet) Temp. Control Range 15~45℃ Temp. Control Accuracy ±0.1℃ Humidity Control Range (5~90)%RH Humidity Control Accuracy ±1%RH Permeation Area 50.24 cm² Sample Size Φ100 mm Sample Thickness ≤3 mm Test Quantity 1 piece Carrier Gas 99.999% Nitrogen (User Provided) Carrier Pressure ≥0.1 MPa Carrier Flow 0~100 mL/min Gas Interface 1/8 inch Metal Tube Dimensions 380×620×385mm Weight 25kg Power 450 W Power Supply AC 220 V, 50 Hz   Product Features Core Technology & Upgraded Operation: High sensitivity, precision and stability of the sensor, capable of testing high-barrier materials in electronics, photovoltaic, solar, display and other fields. Brand new pneumatic control system, automatic fixture locks sample with one key, convenient and labor-saving, with excellent sealing performance. Precise Temperature & Humidity Control: Temperature: Bi-directional automatic control via semiconductor cooling plate, accuracy ±0.1℃. Humidity: Dual-airflow (dry & wet) humidity control method, stable and high precision, accuracy ±1%RH. Strong Expandability: With optional accessories, it can test water vapor transmission rate of packages and containers. Excellent Appearance & Real-time Visual Curve: Built-in 11.6-inch high-resolution color touch screen, clear view, sensitive touch. Fully automatic operation, one-key test, automatic judgment and shutdown. Real-time display of 5 groups of curves (permeation rate-time, temp-time, humidity-time, concentration-time), with preview/hide function. Intelligent OS & Global Certification: Self-developed intelligent OS, modular interface, flexible parameter setting. Designed in accordance with GMP Computerized System, with audit trail and multi-level user authority, meeting pharmaceutical industry data traceability requirements. Customizable test reports, multiple data output formats, electronic signature and online report approval. Professional Calibration & Reliable Data: Our company possesses the National Standard Material Classification Certificate for water vapor transmission rate approved by the State Administration of Quality Supervision, Inspection and Quarantine (GBW(E)130543 / GBW(E)130544). Self-developed national standard materials are used for instrument calibration, ensuring accurate, universal and authoritative test data.   Application Fields Packages & Containers Custom fixtures for pharmaceutical BFS, ointment tubes, infusion tubes. Chip Packaging Materials FR-4, BT resin, PI, ABF film, Al₂O₃ ceramic, metal substrate testing. Solar Cell Barrier Materials Solar backsheet, butyl rubber, ALD Al₂O₃, POE, EVA film testing. Display Field Barrier Materials For LCD high-barrier materials such as epoxy resin film, SiNx passivation film, modified PET Other Materials Ultra-high barrier materials for pharmaceutical, food, daily chemical industries.   Why Choose Us ✓ Professional R&D & Manufacturing We have professional R&D team and complete production line, focusing on physical property testing instruments for more than 20 years, providing reliable and stable testing equipment for global customers. ✓ High Precision & Quality Certification Products comply with international standards, equipped with high-precision sensors and intelligent control system, with national standard material certification and authoritative qualification. ✓ Perfect After-sales & Technical Support Global after-sales service network, timely technical guidance, professional training and lifelong maintenance services to ensure worry-free use. Guangzhou GBPI Packaging Equipment Co., Ltd. | Professional Testing Instrument Manufacturer  
Falling ball impact tester Falling ball impact tester GQ-D1
  GQ-D1 Drop Ball Impact Tester High Precision Impact Resistance Tester for Packaging PRODUCT PROFILE GQ-D1 Drop Ball Impact Tester is mainly used for testing the impact resistance of hard sheets for food packaging and solid pharmaceutical hard sheets. Traditional electromagnets generate high temperature and residual magnetism after power off, affecting accuracy. This instrument adopts the principle of electromagnetic repulsion, which can automatically release residual magnetism and avoid high temperature, ensuring experimental accuracy. It features high-precision control, intelligent operation and complete safety protection, widely applied in food and pharmaceutical packaging quality control. TEST PRINCIPLE Place the test product on the test bench. Let a steel ball of specified weight fall freely from a specified height to impact the product. Then check the product's appearance for damage and various performance indicators. COMPLIANCE STANDARDS GB/T 15267 YBB 0021-2005 YBB 00202005 YBB 00222005-2015 TECHNICAL PARAMETERS Item Parameter Impact Height 0~900 mm Steel Ball Φ23mm (50g), Φ25mm (60g), Φ28.6mm (100g), Φ38.1mm (225g) Clamping Range 120mm × 85mm Sample Size 150mm (L) × 50mm (W) Dimensions 325 × 550 × 1341mm Weight & Power 30kg, 75W, AC 220V 50Hz PRODUCT FEATURES Touch Screen Control Color touch screen for intuitive and easy operation. Anti-Residual Magnetism Electromagnetic repulsion principle, no residual magnetism or high temperature. Pneumatic Clamping Auto clamping/release reduces error and test time. Built-in Printer Instant test report printing and data query. Intelligent Test Intelligent testing process, greatly improve work efficiency. Accurate & Reliable Stable structure and accurate test results. APPLICATIONS Food Packaging Hard Sheets For PVC hard sheets in food packaging, quality control for food & packaging enterprises. Solid Pharmaceutical Hard Sheets For pharmaceutical hard sheets, quality control for pharmaceutical & packaging enterprises. © 2025 GBPI | GQ-D1 Drop Ball Impact Tester | Professional Testing Solution
Falling Dart Impact Tester Falling Dart Impact Tester Test Plastic film Sheet Flexible Package GBD-L
GBD-L Falling Dart Impact Tester test the impact resistance of various films, metallic foil and so on, widely used in industries of packaging, plastic films, laboratory, research institute, inspection agency and so on.
Professional high accuracy barrier film Electrolytic sensor method water vapor permeability analyzer-W203 2.0 supplier high accuracy barrier film Electrolytic sensor method water vapor permeability analyzer-W203 2.0
W203 2.0 Water Vapor Transmission Rate Tester Electrolytic Method | High Barrier Materials WVTR Testing Product Introduction W203 2.0 is developed based on the electrolytic test principle, designed and manufactured in accordance with GB/T 21529, ISO 15106-3 and other international standards. It tests water vapor transmission rate of samples under controlled temperature and humidity, widely used for high barrier materials in LCD, solar cells, chip packaging, pharmaceuticals, food and more. Get a Free Quote Today   Test Principle W203 2.0 adopts the electrolytic method. The pre-treated sample is fixed in the test chamber, separating it into wet and dry sides. Humidified nitrogen flows on one side of the film, while dry nitrogen (carrier gas) flows on the other side at a fixed rate. Due to humidity gradient, water vapor permeates from the wet side to the dry side, carried by dry nitrogen to the electrolytic sensor. The WVTR value is calculated from the electrical signal output by the sensor.   Compliant Standards 2025 Chinese Pharmacopoeia 4010 GB/T 21529-2008 ISO 15106-3 DIN 53122-2 YBB 00092003-2015 ASTM F3299 JIS K7129-3   Technical Specifications Item Value Test Range 0.001~40 g/(m²·24h) (Film & Sheet) Resolution 0.0001 g/(m²·24h) Temperature Range 15 ~ 45℃ Temperature Accuracy ±0.1℃ Humidity Range 5 ~ 90%RH Humidity Accuracy ±1%RH Test Area 50.24 cm² Sample Size Φ100 mm Test Chambers 3 channels (independent data)   Key Features High-sensitivity sensor for ultra-high barrier materials in electronics, photovoltaics, displays. Automatic pneumatic clamping system, one-key locking, excellent sealing. Precise temperature & humidity control: ±0.1℃, ±1%RH. 3 independent test chambers for high-throughput testing. 11.6-inch HD touch screen, real-time test curves display. Intelligent OS with audit trail, multi-level user rights, GMP compliant. Calibrated with national standard substances for accurate & authoritative data.   Applications Display MaterialsLCD sealant, SiNx passivation film, modified PET, etc. Chip PackagingFR-4, BT resin, PI substrate, ABF film, ceramic substrate. Solar MaterialsSolar backsheet, butyl film, ALD Al₂O₃, EVA/POE film. Packaging ComponentsPharmaceutical tubes, BFS bottles, infusion hoses, containers. Pharmaceutical & FoodUltra-high barrier films and packages for medical and food use.
  • Facebook
  • Linkedin
  • Youtube
  • Twitter

Copyright @ 2026 Guangzhou Biaoji Packaging Equipment Co.,Ltd. All Rights Reserved.

Chat now

Inquiry Now

Home

Products

NEWS

contact