packaging testing equipment Water Vapor Permeation Tester
Products
Home /

Physical Property Test Equipment

/

Pendulum Impact Tester

/Incline Impact Testers For Packages Packaging Impact Strength Test ISTA 6 Packaging Test Bundle

Incline Impact Testers For Packages Packaging Impact Strength Test ISTA 6 Packaging Test Bundle

The Inclined Impact tester is simulated the impact strength of packaging in the real circumstance of transport such as handling, stacking of shelves, sliding, loading , transportation of products. This product is also can supply as the test machine to scientific research institution, college, packaging technique test centre, packaging material manufacture and foreign trade or transport department.

Inquiry now
Product Detail

Test Application

Packaging Testing Instuments

Paper and Cardboard Testing


1. The test principle of inclined plane impact is using the principle of transforming the potential energy of an object into kinetic energy, when the package glides to the end according to the predetermined position, a certain impact velocity is obtained to collide with an impact plate perpendicular to the velocity direction to achieve the predetermined test purpose.

2. Based on the principle of transforming the potential energy of an object into monopoly kinetic energy, when the package is positioned with a free sliding bottom, the impact plate with a certain impact velocity perpendicular to an acceleration direction can be collided to achieve the fixed test.

3. The bevel impact testing machine can simulate the horizontal impact and collision environment of packages and containers in the process of transportation. it can be used as a common test equipment for oblique impact in scientific research institutions, colleges and universities, packaging technology testing centers, packaging material manufacturers, foreign trade, transportation and other departments.


Standard

ISO 2248ISTA

Technical parameters

Item

Technical parameters

 

Maximum load

200kg

Worktable size

1100×1100mm

Baffle size

1600×2000mm

 Impact Speed Deviation

≤±5%

Impact velocity range

1.2~3.87m/s

Features

  Flexible low-resistance with high repetition accuracy to reaching the required speed.

  Hard wooden or iron sliding table to effectively protect the surface of the specimen

  Perfect control and measurement system, simple and convenient operation, integrated control and measurement.

  The customer only need to fix the machine on the ground when stalling, no other complicated operation convenient for test.


Send A Message

Leave us a message, we will get back to you ASAP.

Related Products
Pendulum Impact Tester Pendulum Impact Tester High Impact Speed Scale Value GBD-B
GBD-B Pendulum Impact Tester test the impact resistance of various films, metallic foil and so on, widely used in industrial and mining enterprises, laboratory, scientific research, teaching, inspection agency and so on.
Film Pendulum Impact Tester Pendulum Impact Tester-GBG-L2
Introduction Designed and manufactured according tostandards likeGB/T 8809、ASTM D3420, GBG-L2 Pendulum Impact Tester is suitable for determining pendulum impact resistance of the film materials,composite film,metallic foil and so on. The machine can be used in scientific research, teaching, industrial and mining enterprises, laboratory, research institute and quality supervision department.
Disinfection Equipment Mobile Atomizing Humidification And Disinfection Equipment - GB-D100
For disinfection of large spaces. Removable aerosol disinfection and sterilization equipment, manual and automatic control, timing and quantitative spraying, adjustable spray volume Suitable for hospitals, campuses, stations, airports, and other large public places. Under the action of compressed air, the medicinal solution is spouted from the nozzle to form aerosol ions of 2 to 10 μm, which quickly and fully integrates in the ambient air; kills pathogenic microorganisms in the air, and realizes a full range of dead space-free disinfection of the environmental space. Sterile environment. The sterilized objects will not form dew condensation and form droplets.
Xenon arc lamp aging test chamber Xenon arc lamp aging test chamber GB-OXD-15P
  1.Profile Xenon lamp aging test chamber simulates the full spectrum lamp with Xenon arc lamp to reappear the destructive wave. It serves for the environmental simulation and accelerated test for research and development, product development and quality control. Besides, the chamber also applies to the choice of new material, weathering test after composition of material and improvement for the current material. It simulate different environment, and show the material changes under the explosion of sunlight.   The chamber meets the standard: GB/T16585-1996 , GB14522-93 , GB/T16422.3-97, ASTM D2565 and so on. The Chamber is to determine the color fastness, aging resistance of textiles, plastics, coatings, rubber products or other materials by objecting to the simulated conditions of nature weather (sun, rain, temperature and humidity, etc.).     Technical parameters   2.Material of construction u Full spectrum lamp u Optional filter system u Water spraying function u Humidity control u Temp. control system in the chamber u Sample fixed hold of irregular shape u USA imported xenon arc lamp u Easy installation and operation, seldom daily maintainance. u Service life time deepens on the irradiance level, usually 1600hrs. It’s easy to replace the lamp, with filter of long service life time to ensure the necessary spectrum. 3.Technical parameters Model No., equipment name GB-OXD-15P Xenon aging test chamber Interior sizes   W500×D500×H600mm  Exterior sizes W1050×D1050×H1750mm (or so) Temperature range 0℃~80℃ Controller imported programmable 7inch touch screen Machine components material inner and outer 304# stainless steel Sample holder Aluminum alloy frame base Protection device residual-current circuit breaker (RCCB) to control the warning for loop overload, thermal protection and water shortage protection. Temp. deflection ±2℃  (without lighting) Humidity range 30%~98%R.H Humid. deflection ±2.5%R.H(Humid.≥75%R.H); ±3%R.H(Humid.≤75%R.H) without lighting Light source imported full spectrum xenon arc lamp(average useful life 1600hrs) Raining time 1~9999min (adjustable) Raining period 1~240min, interval(cut)adjustable lamp power Test period for Temp., irradiation, condensation, spray can be adjustable Lamp 1.8KW Wave length range 290-800nm heating power (or so) 4.0KW humidification (or so) 2.0KW Light irradiance 1200w/m2 Distance between arc center and sample holder: 350~380mm Revolving speed of sample holder ≥1r/min  water spray period a. spray time: 0~99h59min (Continuing or adjustable) b. stop time: 0~99h59min, (Continuing or adjustable)   lighting time Continuing programming control available black panel temp. 85±3℃ cooling method Mechanical wind cooling; Room temp. less than 26℃ is recommend, relative humid: ≤85%R.H; humid. and temp. tested after 2 hours under idle condition. 4.Temperature & humidity running control system controller imported programmable 7inch touch screen precision range set precision: temp. ±0.1℃, humid: ±2%R.H, indicated precision: temp.±0.1℃,humid.: ±1%R.H temp. & humid. sensor Platinum Resistance(PT100Ω/MV) black panel temp. double-metal black panel temp. thermometer water-supplying system auto-control humidication water-supplying, Xenon arc lamp with cycling cooling water circulation system low noise heat-resistance conditioning motor, multi-blade centrifugal wind wheel control system mainly consists of operation panel, central controller, kinds of key-pressing sw., status indicating lamp, excution electric device etc.. 5.Structure section of machine body The chamber consists of several section: chamber body, control system, refrigeration system, heating system, humidation system, wind system, raining system, lighting system and so on. Chamber body a. With integrated structure, the chamber consists of up left part as working room, up right part as electric controller which is convenient to control, down part as compressor cooling group, sample holder rotation device, Xenon lamp condensation water box, water pump and other executive devices. b. Inner wall of chamber adopts international SUS304# material. c. Temp. insulation material is polyurethane foam and ultra-fine fibre glass, with good temp. insulation result, no frost and condensation on the external surface of chamber. d. condensate water outfall set at the bottom of chamber e. Environmental heat-resistance silicon sealing tape as the material of door frame. f. Viewing window with eye-protective film on its surface to protect eyes from being injured by Xenon lamp. external chamber body a. Seal of door adopts the double-layer of refined silicone rubber with reliable sealing effect and no aging or hardening phenomenon under high or low temperature. b. Single door (embedded handle); c. Viewing window, antifrost device and lamp equipped on the door viewing window Size:25 cm W × 30 cm H;equipped with Anti-radiation hollow glass 6.Electric control section of chamber a. As the core part of chamber b. Air pressure switch as the main switch to control the main circuit; c. Safety measures for electric section: it warns and cut electricity automatically after tested the action from following protection devices: a) overheat protection in working room b) lockage of phase, leakage protection c) overcurrent protection of motor d) overpressure/overload protection of cooling machine e) short out/overload protection of heater, humidifer f) fusing protection of fuse 7.Working section of chamber Condensation section of compressor. a.Cooling system: as the core part of cooling system, we adopt one set of compressor of Tecumseh from France in this case to ensure the cooling requirement in the working room. b.For adjustment technology and design of cooling system, we take an efficiency processing way to ensure the adjustment for the cooling amount and consumption of cooling system under the normal running, to make the failure rate down to the economical statue. c.Cooling evaporator: it locates in interlayer at one side of chamber which ventilate by force from blast motor to exchange heat fast. d.Cooling method of cooling system: forced air cooling Cooling refrigerant:Environmental R404a; Heating system a. Heating method: heating directly in the chamber; b. Military level stainless steel heating tube used, with fast and stable heating to keep temperature in the working room from rapid change. It with corrosion resistance, anti-high-low temperature, no leakage and other advantages. c. With SSR (solid relay)output control, without noise, reliable working, long service life time, fast switching, low interference from outside, and easy operation etc.. Rain system.   it consists of nozzle, solenoid valve, water-supplying and connecting pipe. Lighting system. It consists of xenon lamp, lamp cover, lamp contactor and other controlling parts. Energy compensation is got by adjusting samples distance, pressure and current. Wind system  It locates in the interlayer at the back of chamber, there are heater, fan blade, evaporator, PT100 temperature samples sensor etc.. when wind machine running, the air is intaken to the channel from working room, and blow out from the bottom after cooled; the air exchanged in the working room with samples is intaken again to the channel and mix; after several circulation, it will reach the purposed temperature, and ensure the high index of temp. and humid in the chamber at the same time. Cooling dehumidification system take the compressor of world brand Tecumseh from France to keep constant temperature, decrease the humidity in the working room and cool the xenon lamp. Humidification Steam generator: to generate steam from water Water level control: control the water inlet by solenoid valve, and water level by liquid level switch to provide the signal for water-supply and warning. Air circulation section Cycling channel and winding machine inside the chamber, it uses the high efficiency cooling machine and energy adjusting system, efficiency heat exchange to reach the aim of temperature change, which also improves the airflow and heat exchange between airflow, heating and humidification, as a result, it improves the humidity uniformity in the working room. 8. Enclosured files: operation manual, warranty card 9. Machine running requirements Temp. 5℃~+32℃ Humidity ≤85% Power supply AC220(±10%)V/50HZ    10. Core components parts Remark: replacement of some small parts of the same quality is possible because of material shortage.    
Lab  Teser Use for fabric China meltblown tester ppe testing equipment for fabric viral filtration efficiency tester
It is used to test the percentage of materials containing bacteria suspended particles at the specified flow rate. The dual gas path simultaneous comparison sampling method is used to improve the accuracy of sampling, which is suitable for the performance testing of bacterial filtration efficiency of medical surgical masks by metrological inspection departments, scientific research institutes, medical mask manufacturers and other relevant departments.
synthetic blood penetration tester Mask Synthetic Blood Penetration Tester
It is suitable for the resistance of the mask to the penetration of synthetic blood under different levels of test pressure. The mask material is tested with synthetic blood under continuously applied pressure, and the penetration of synthetic blood on the material is visually checked.
Oxygen Gas Permeability Tester Oxygen Permeability Analyzer - Coulometric Sensor Method
This product is based on the testing principle of the coulometric sensor method testing Oxygen, and is designed and manufactured with reference to ASTM D3985 and other standards. Adopting high-precision imported oxygen sensor, high test accuracy,it is suitable for oxygen transmission performance testing of films, sheets, paper, packaging and related materials in the fields of food, medicine, medical equipment, daily chemicals, photovoltaic electronics, etc., and provides a wide range and high-efficiency oxygen transmission rate detection for high, medium and low oxygen barrier materials.
6 GBB-R1 Melt Flow Indexer (MFI)
Introduction It is used to determine the MFR & MVR value of the melt flow rate through the standard die every 10 minutes when various plastics and gums pass through a certain temperature and load in a viscous flow state. It is suitable for melting high temperature polycarbonate, polysulfoxide, fluorine plastics, nylon and other engineering plastics. Also, it is appropriate for the polyformaldehyde, polystrene, polypropylene, ABS resin polyformaldehyde, polycarbonate resin and other low temperature plastic melting test. The machine is widely used in plastic production, plastic products, petrochemical and other industries as well as related universities, scientific research units and commodity inspection departments. 
color measurement device Portable Handheld Spectrophotometers for Plastic Electronic Painting Coating Ink Textile etc Colorimeter Color Difference Meter Tester
Application It is used for accurate color analysis and transmission; it is used for precision color measurement and quality control in plastic electronics, paint ink, textile and garment printing, printing, ceramics, etc.; it can be used for fluorescence sample measurement.
water vapor permeability WVTR MVTR Water Vapor Transmission Rate Testing Instrument Infrared Method for Plastic Film and Sheeting-W413
Moisture vapor permeability analyzer using infrared method is to test the water vapor transmission rate (WVTR) of films or sheets materials for food and pharmaceutical industries.
Headspace Gas Analyzer Headspace Gas Analyzer-GB-DK
Product Introduction The headspace gas analyzer adopts the destructive puncture detection method and is equipped with high-precision oxygen sensors and carbon dioxide sensors to accurately detect the O2 and CO2 content of hollow packaging containers such as packaging bags, bottles, cans, etc. The analysis of the content of the headspace gas in the packaging can make a reasonable judgment on the product quality, the validity of the shelf life prediction, and the rationality of the packaging design. At the same time, it can also be used as a means of packaging tightness testing. It is a better choice for modified atmosphere preservation (MAP, CAP) packaging, large infusion bottles (bags), residual oxygen in the headspace of prefilled needles, residual oxygen detection in vials, and the results of residual oxygen detection for various food and medicines. Nowadays, the headspace gas analyzer has become an important method to check the quality of packaging design and one of the important methods to verify the product shelf life. Our headspace gas analyzer GB-DK can quickly detect O2 in production lines, warehouses, laboratories and other occasions. And CO2 content to guide production.   Test principle The gas in the sample is drawn into the sensor by a vacuum pump. The sensor outputs the current and voltage signals of the O2 and CO2 (optional) concentration in the gas in the sample in real time. The instrument calculates the content of O2 and CO2 in the gas by obtaining the current and voltage signals output by the sensor. After reaching the end conditions of the experiment, the test stops, and the instrument records the concentration of O2 and CO2 in the measured gas in the sample.   Technical parameter Item Parameter Gas to be Measured O2 (standard configuration) CO2 (optional) Measurement Principle Fluorescence optics infrared absorption Measurement Range 0%~25% (for O2) 0%~100% (for CO2) Measurement Accuracy ±0.2% ±2% Sample Size ≥5 mL (at standard atmospheric pressure) (for O2) ≥20 mL (at standard atmospheric pressure) (for CO2) Dimensions 350 mm (L)×330 mm(W)×200 mm(H) Power Supply 220 VAC±10 % 50Hz/120 VAC±10 % 60 Hz Net Weight 5kg    Features 1.Using high-precision sensors, high accuracy, good stability, long-term operation, long service life. Over-range automatic protection function to avoid damage to important sensors when the instrument fails. 2.The needle/probe safety holster is used to ensure safe testing and fast sampling. 3.Oxygen and carbon dioxide can be detected at the same time, and carbon dioxide gas can be selected for analysis according to different user needs. The sampling volume is at least 3 ml. 4.Built-in operating system, the system is equipped with an ARM control system to control the host through a touch screen (testing equipment and control software are combined into one); at the same time, the system can be expanded, such as connecting to the laboratory LIMS system. 5.The software is designed according to the requirements of the computerized system in the new version of the GMP appendix, and users are divided into multiple levels such as operators and administrators (such as administrators, operators, observers, etc. but not limited to these levels). 6.It has the audit trail function, which can realize the audit trail of the system, project operation, and method to ensure the safety and integrity of the test data. 7.Personalize the test report, set the report module that needs to be displayed, and output the report in PDF mode. The micro printer can print test reports in real time.  
Professional Packaging lab equipment high accuracy barrier film water vapor permeability analyzer moisture vapour transmission rate supplier Packaging lab equipment high accuracy barrier film water vapor permeability analyzer moisture vapour transmission rate
  Application W413 2.0 water vapor permeability tester is designed to test the water vapor transmission rate (WVTR) of films or sheets materials.  
  • Facebook
  • Linkedin
  • Youtube
  • Twitter

Copyright @ 2025 Guangzhou Biaoji Packaging Equipment Co.,Ltd. All Rights Reserved.

Chat now

Inquiry Now

Home

Products

NEWS

contact