packaging testing equipment Water Vapor Permeation Tester
Products
Home /

Glass Container Test Equipment

/Electronic Bottle Wall Thickness Gauge

Electronic Bottle Wall Thickness Gauge

Laboratory Glass Package Tester for Ampoule, injection bottle, infusion bottle, oral medicine bottle. Thickness testing, Burst, testing, Pressure Resistance testing, and Thermal Testing for Medical/Pharma Packages. 20+ Years Test Experience.
  • Brand:

    GBPI
Inquiry now
Product Detail

Electronic Bottle Wall Thickness Gauge

Bottle Wall Thickness Gauge

General Application

CHY-G Electronic Bottle Wall Thickness Gauge is suitable for measuring the thickness of the bottom and wall of glass bottles in the pharmaceutical and food industries. Based on traditional thickness measuring instrument, the instrument adds a tray to stabilize the bottle, avoiding measurement errors caused by shaking of the bottle.


Techniques

  • 7-inch color touch LCD screen, microcomputer control, automatic grouping and calculate maximum, minimum and average values.
  • Real-time display of rotation angle to ensure accurate return of measurement.
  • Meet two test methods of bottom thickness and wall thickness.
  • New added bottle supporting device on measuring platform supports adjustment of up and down, which makes the test easy and convenient.
  • System supports micro-printing.
  • Software user hierarchical authority management, data statistics and audit functions to meet industry requirements.


Specific Applications

Basic

Tests for thickness of bottle wall and bottom

For glass ampoules, glass tube bottles, glass molded bottles, glass tube injection bottles, glass molded injection bottles and oral liquid bottles.

Tests for thickness of bottle wall and bottom

For glass infusion bottles, beer bottles, spirits bottles, wine bottles, mineral water plastic bottles and carbonated beverage plastic bottles.



Measurement Principle

CHY-G Electronic Bottle Wall Thickness Gauge adopts capacitive displacement sensor technology. The measuring head contacts the bottle and corresponds to the dart head. The capacitive displacement sensor in the two systems collects the response data and then calculates the corresponding bottle wall/bottom thickness through the system.


Standards

YBB00332002-2015: Ampoules made of low borosilicate glass tubing

YBB00332003-2015: Injection Vials Made of Soda Lime Glass Tubing

YBB00032004-2015: Oralliquid bottles made of soda lime glass tubing

GB 12415-90: Pharmaceuticalglasscontainers- Stressexamination-Testmethods


Technical Specification

                      Items

CHY-G Electronic Bottle Wall Thickness Gauge

Measurement range

0-12.7mm/0.5

Division value

0.001mm/0.00005″

Sample diameter

5mm-300mm(customized support

Sample height

5mm-330mm (customized support)

Size

400(L)X 360(W)X 700(H)mm

Communication connector

USB connector

Environmental temperature

15-50℃

Environmental humidity

10-90%, no condensation

Power

220V/50Hz/60W












Send A Message

Leave us a message, we will get back to you ASAP.

Related Products
Professional Cap Torque Tester supplier Cap Torque Tester
Cap Torque Tester HP-100  It is used for testing the lock and open torque of the bottle cap for pharmaceutical packaging. Combined with leakage tester it can measure the sealing of medicine bottles.
Tensile Test Sample Cutter Tensile Test Sample Cutter - LC-1
LC-1 Tensile Test Sample Cutter cuts samples of plastic film, paper and so on in preparation for other tests, such as tensile, peeling, tearing and heat sealing etc. It is compactly structured and easy to use. The edges of sample cut out are even and smooth.
migration testing in food packaging GBPI Migration Testing equipemnent In Food Plastic Packaging Migration & Non-volatile-matter Content Tester
  ZF3600 Full-automatic Total Migration Tester is applied to determinate the dissolution amount of packaging materials in different simulant soaking solutions.  
Pendulum Impact Tester Pendulum Impact Tester High Impact Speed Scale Value GBD-B
GBD-B Pendulum Impact Tester test the impact resistance of various films, metallic foil and so on, widely used in industrial and mining enterprises, laboratory, scientific research, teaching, inspection agency and so on.
Ink Rub Tester GX-C2 Rub Tester Ink Rub Tester - Rub Tester for Ink, Coating
GX-C2 Rub Tester is suitable for testing the abrasion resistance of printing ink layer of printed matter, the abrasion resistance of PS plate photosensitive layer and the abrasion resistance of surface coating of related products. It can effectively analyze the problems of poor rub resistance of printed matter, peeling of ink layer film, low printing endurance of PS version and poor coating hardness of other products.
medical sterilized boiler ZM-100 inverted pressure sterilized boiler
ZM-100 Inverted pressure sterilizer boiler is used for sterilization and high temperature test of packaging materials (including adhesives and printing ink) in the industries of packaging, plastic films, food, medical units, inspection agency, research institute etc.
oxygen permeability tester Oxygen Permeability Analyzer Equal pressure method-Y110
Y110 Oxygen Permeability Analyzer to test the oxygen transmission rate (OTR) of films or sheets materials.
Vacuum Freeze Dryer Vacuum Freeze Dryer GB-LGJ-200F
Introduction Factory use vacuum freeze dryer is suitable for drying product such as food, drug products, biological products, Chinese medicine and more. It is to dry product at low temperature to preserve, stabilize, store and increase the life of products.. Freeze vacuum drying is a new type of box structure introduced by the vacuum freeze dryer that combines the refrigeration system, vacuum system, heat transfer oil heating system, and moisture removal system. It uses the space for storing materials in the box to dry. Main Technical Parameters   Item GB-LGJ-200F Drying chamber Freeze-drying area 2.25m2 Layers of shelf 5+1 Temperature scope of shelf -50℃-+70℃ (no-load) Shelf temperature error ±1℃ (in balance) Shelf spacing 70mm Size of shelf 500mm*900mm Condenser Min. Temperature of condenser ≤-70℃ (no-load) Water-capture capability >30Kg Liquid material 22L(thickness 10mm) Defrosting Electric defrosting Final Vacuum degree ≤ 5Pa Style of cooling Fan cooling Main functions Manual + Auto Control Mode, Sensor calibration, Intelligent temperature control, Freeze drying termination reminding and other functions are available.               Technical parameters □ Main configuration   Shelf effective area 2.25 m2 □ Specification   Shelf size 500mm × 900mm   Shelf numbers 5+1(Radiation layer) Top shelf as temperature compensating plate   Material number plate 10 pcs   Shelf spacing 70 mm   Shelf temperature range -50℃~+70℃ (no-load)   Min. condenser temp. ≤ -70℃  (no-load)   System final vacuum degree ≤ 5Pa □ Basic configuration    Installation Power 13.5KW     ★ This is installed power, not operating power. □ Shape and other parts   Dimension(mm): About 1200x2100x1700mm, L*W*H   Weight(Kg):  About 1200   Noise ≤ 80dB   Electrical system Ground protection   Design, production, installation standards According to GMP, GB/T522 6.1-1996   Whole machine test Test, verify data, methods, and equipment support □ Drying chamber components   Shape Rectangular   Roughness of inner wall Ra ≤ 0.6μm   Opening direction Clockwise or anticlockwise (overlooking ,user confirm)   Chamber material AISI 304  stainless steel ◆  Door  material ACRYLIC   Working temperature ≥ 70℃   Thermal insulation material Polyurethane foam □ Shelf components ◆ Shelf material AISI 304  Top and bottom plate thickness 5mm ◆ Shelf structure AISI 304 stainless steel (Patent No. :ZL201020237059.X)   Roughness of shelf Ra ≤ 0.6 μm   Flatness ≤ ±0.5mm / m   Effective shelf size 500mm×900 mm   Amount of shelf 5+1     Effective area of shelf 2.25m2 ◆ Shelf spacing  70 mm   Temperature decreasing rate +20℃ down to -40℃/ within 60 min, (no-load, entrance of silicon oil )   Temperature elevating rate -40℃ up to +20℃/ within 60 min, (no-load, entrance of silicon oil ) ◆ Shelf lowest temperature ≤ -50℃      (no-load, entrance of silicon oil )   Shelf highest temperature ≥ +70℃    (no-load, entrance of silicon oil )   Shelf temperature error ≤ ±1℃ ≤ ±1℃ ( in balance ) □ Condenser components   Condenser Shape Vertical type, cylindrical Compact structure, better water capture ,easy to clean and defrosting ◆ Condenser material AISI 304   Condenser water capture ≥ 30Kg   Condenser temp. Decreasing +20℃--40℃, within 30 minutes ◆   Condenser Min. temp. ≤ -70℃   Defrosting Electrochemical cream ◆ Thermal insulation material Polyurethane foam □ Refrigeration system   Refrigerator France original imported TECUMSEH full closure compressor ◆ Refrigerant Environmentally friendly refrigerant   Refrigerator number 2 sets   Shelf refrigeration 1 sets (shelf refrigeration at same time, indirect refrigeration)   Condenser refrigeration 1 set (shelf refrigeration at same time, direct refrigeration) ★ World famous devices are used to make sure correct, stable, safe and reliable.   High pressure protection device When system’s air discharge pressure exceeds allowed pressure, machine automatically stops working, to avoid an accident.   expansion valve DANFOSS(Denmark)   Top cover valve Castel(Italy)   solenoid valve DANFOSS(Denmark)   Oil separator ZOER   High pressure controller DANFOSS(Denmark)   Disacidify filter DANFOSS(Denmark)   Pressure meter LR/REFCO LR/REFCO(Germany/Swiss) oil submerge  pressure meter   Water cooling condenser Well-known brand □ Vacuum system ◆ Double stage rotary vane pump Tan's Vacuum Pump   Quantity 1 set ◆ Vacuum gauge Reborn   Chamber pumping rate Atmosphere→10 Pa ≤30 minutes(in dry condition)   System Maximum vacuum ≤ 5Pa   System leaking rate ≤ 10 Pa·l / sec □ Liquid circulation system ◆   Liquid low viscosity silicon oil ( 25℃, 5cst ) National qualified product   Liquid tubing material AISI 304, welding, heat  keeping ◆ Circulation pump ★GRUNDFOS, original imports, web rotor canned pump From Denmark brand, world famous brand   Circulation pump quantity 1 set   Heating rate 4kW   Heating control style Solid-state relay ◆ Stainless steel plate heat exchanger Well-known brands   Temperature sensor PT-100 platinum resistance □  Control system ◆ Control style Automatic and manual control ◆ Control system FD-PILOT   Control board SH-HPSC-II   Touch screen MCGS   Intermediate relay CHINT   AC contactor CHINT   Air circuit-breaker CHINT   Wiring terminals: Well-known brands □ Safety protection   Whole machine protection All safety conditions are ready for whole machine, machine can start running.   Operation protection Electrical system have logic interlock, control and protection function   Vacuum pressure Available   Heating system Available   Power cut and supply With safety protection measure   Products protection during sublimation process Heat cutting if vacuum lack   Condenser protection when vacuum pump start Interlock □ Whole machine design   Power 3Ph+N+PE, 380V   Installed power 13.5 KW (this is installed power, not running power)   Whole machine structure Integrated structure (easy for transport and placement)   Whole machine size About  1200x2100x1700mm, L*W*H   Whole machine weight (kg) About 1200   Time of warranty: One year after site acceptance.  
Disinfection Equipment Mobile Atomizing Humidification And Disinfection Equipment - GB-D100
For disinfection of large spaces. Removable aerosol disinfection and sterilization equipment, manual and automatic control, timing and quantitative spraying, adjustable spray volume Suitable for hospitals, campuses, stations, airports, and other large public places. Under the action of compressed air, the medicinal solution is spouted from the nozzle to form aerosol ions of 2 to 10 μm, which quickly and fully integrates in the ambient air; kills pathogenic microorganisms in the air, and realizes a full range of dead space-free disinfection of the environmental space. Sterile environment. The sterilized objects will not form dew condensation and form droplets.
Professional W416 2.0 Water Vapor Transmission Rate Tester supplier W416 2.0 Water Vapor Transmission Rate Tester
W416 2.0 Infrared Water Vapor Transmission Rate Tester High Precision WVTR Tester | 6 Independent Test Chambers Product Introduction W416 2.0 Infrared Water Vapor Transmission Rate Tester is an upgraded high-end precision testing instrument developed by GBPI R&D team in accordance with GB/T 26253, ASTM F1249 and international standards. Based on infrared moisture sensor technology, it provides wide-range and high-efficiency WVTR test for high, medium and low barrier materials. It is widely used for films, sheets, paper, packages and materials in food, pharmaceutical, medical devices, daily chemical, photovoltaic and electronics industries, ideal for offline and online testing in packaging industry. Get a Free Quote Today   Test Principle W416 2.0 adopts the infrared sensor testing principle. The pre-processed sample is fixed in the test chamber, dividing it into wet and dry sides. Compressed air flows in the wet chamber, and dry nitrogen (carrier gas) flows in the dry chamber at a fixed rate. Due to humidity gradient, water vapor permeates to the dry chamber and is carried to the infrared sensor. The WVTR value is calculated by the electrical signal output from the sensor.   Compliant Standards ISO 15106-2 ISO 21760-1 ASTM F1249 GB/T 26253 JIS K7129-2 Chinese Pharmacopoeia 4010 YBB 00092003   Technical Specifications Item Value Test Range 0.002~100 g/(m²·24h) Repeatability 0.005 or 2% (whichever is greater) Resolution 0.0001 g/(m²·24h) Temperature Range 15~45℃ Temperature Accuracy ±0.1℃ Humidity Range 5~90%RH, 100%RH Humidity Accuracy ±1%RH Test Area 50.24 cm² Sample Size Φ100 mm Sample Thickness ≤3 mm Test Chambers 6 channels (independent data)   Key Features Patented high-precision infrared moisture sensor, ultra-high stability, resolution up to 0.0001 g/(m²·24h). Automatic pneumatic control system, one-key sample clamping, excellent sealing and easy operation. Precise temperature & humidity control: ±0.1℃, ±1%RH, stable and reliable test data. 6 independent test chambers for high-throughput and high-efficiency testing. Real-time display of 5 test curves: WVTR-time, temperature-time, humidity-time, flow-time, voltage-time. Intelligent OS with audit trail, multi-level user rights, fully compliant with GMP. Calibrated with national standard substances (GBW(E)130543 / GBW(E)130544) for authoritative data. Support laboratory intelligent IoT platform: remote data management, remote diagnosis, resource download.   Applications Plastic Films PET, PE, BOPP, composite films, degradable films, aluminum-plated films, etc. Sheets Pharmaceutical rigid sheets, metal composite sheets, rubber sheets, etc. Paper & Paperboard Coated paper, aluminum paper, paper-plastic composite materials, etc. Medical Patches Medical plasters, transdermal patches, healthcare dressings, etc. Packaging Components Bottles, tubes, trays, bags, plastic containers, etc.
Professional Paper & Paperboard Air Permeability Tester supplier Paper & Paperboard Air Permeability Tester
Product Brief The N600P Paper & Paperboard Air Permeability Tester is custom-developed to align with standards like GB/T 458-2008 and ISO 5636. It adopts the differential pressure method as its core testing principle, and innovatively integrates three industry-common testing approaches (Gurley, Schopper, and Bendtsen) into a single device.   This tester is applicable to air permeability detection of various paper and paperboard materials, and can measure key indicators including: material air permeability, air resistance, gas transmission rate, and total gas transmission volume. Testing Principle Gurley Method   Under a constant differential pressure of 1.23 kPa, measure the time required for 100 mL of gas to pass through the sample. Schopper Method   Select a suitable test duration under a constant differential pressure (1.00 kPa±0.01 kPa or 2.50±0.01 kPa), and calculate the gas flow rate through the sample by measuring the gas volume. Bendtsen Method   After clamping the sample for 5 seconds under a constant differential pressure of 1.47 kPa, test the gas flow rate through the surface of the sample. Executed Standards GB/T 458-2008, SJ/T 10171-2016, ISO 5636-5:2003, ISO 5636-2:1984, ISO 5636-3:2013, TAPPI T460 Technical Parameters   Item Technical Parameters Test Range 0.1~10 μm/(Pa·s) Resolution 0.001 μm/(Pa·s) Differential Pressure Range 0~5 kPa Pressure Resolution 0.001 kPa Test Area 6.42 cm² or 10.0 cm² Sample Size >50 mm×50 mm Instrument Dimensions (L×W×H) 450 mm×400 mm×300 mm Power 100 W Power Supply 110~250 VAC, 50~60 Hz
Professional Cap Torque Tester supplier Cap Torque Tester
Cap Torque Tester HP-100  It is used for testing the lock and open torque of the bottle cap for pharmaceutical packaging. Combined with leakage tester it can measure the sealing of medicine bottles.
  • Facebook
  • Linkedin
  • Youtube
  • Twitter

Copyright @ 2026 Guangzhou Biaoji Packaging Equipment Co.,Ltd. All Rights Reserved.

Chat now

Inquiry Now

Home

Products

NEWS

contact