packaging testing equipment Water Vapor Permeation Tester
Products
Home /

Physical Property Test Equipment

/

Coefficient of Friction Tester

/GM-1 0-10N plastic film packaging coefficient of friction tester

GM-1 0-10N plastic film packaging coefficient of friction tester

The coefficient of friction tester is used to test the coefficient of frictionof plastic film, thin sheet, paper and so on, widely used in packaging industry, film-making companies and packaging material inspection agencies.

  • Brand:

    GBPI
  • Item NO.:

    GM-1
  • Payment:

    TT
  • Product Origin:

    China
  • Lead Time:

    around 7 working days
Inquiry now
Product Detail



Introduction

The coefficient of friction tester GM-1 is a measuring instrument developed and manufactured by the Guangzhou Biaoji R&D team based on various test standards of GB, ISO, ASTM and market demand. The measured friction coefficient determines the smoothness and opening difficulty of the film. and uniformity can be accurately determined, so as to correctly guide the production.

It is suitable for measuring the static friction coefficient, dynamic friction coefficient and peel strength of plastic films, composite films, aluminum foils, aluminized films, plates, rubber, ceramics and other materials when sliding.

Test Principle

Use a clamp to clamp the strip test sample, and wrap the slider with the sample to be tested, and then place the slider on the hanging hole of the sensor. Under a certain contact pressure, the conveyor belt is driven by the motor to move the force sensor. , that is, to move the two test surfaces relative to each other. The force signal measured by the force sensor is amplified by the integrator and sent to the recorder, and the kinetic friction coefficient and the static friction coefficient are recorded respectively.

 

 

Standard

GB 10006、ISO 8295、TAPPI T816

Specification

Item

Technical parameter

COF test range

0.001~0.999

Resolution

0.001

Measurement accuracy

±0.5%FS

Force range

0~9.8 N

Sliding speed

100, 150, 500 mm/min

Stroke

100 mm±5 mm

Sample thickness

≤2 mm

Slider size

63 mm×63 mm

Slider Weight

200 g±2 g

Work platform size

200 mm×470 mm

Instrument size

470 mm×350 mm×220 mm

Power

100 W

Power supply

AC 220 V,50 Hz

Weight

12.5 kg

 

 

Feature

 Instrument is stable, reliable and easy to maintain

 Intelligent operating system

 Laboratory intelligent Iot platform  


Application

 

 

Film

Suitable for static friction coefficient and dynamic friction coefficient test of plastic film and thin film  

 

Paper

 Suitable for dynamic and static friction coefficient test of paper and cardboard

 

 

Textiles, non-woven fabrics, woven bags

 

Suitable for testing static friction coefficient and dynamic friction coefficient of textile, non-woven fabric and woven bag

 

Aluminum foil, aluminum foil composite film, metal products

 

Suitable for testing static friction coefficient and dynamic friction coefficient of aluminum foil, aluminum foil composite film and metal products  

 

Printing product

It is suitable for static friction coefficient and dynamic friction coefficient test of printed matter



Send A Message

Leave us a message, we will get back to you ASAP.

Related Products
coefficient of friction tester New advanced 0.01~0.999 film packaging COF GM-6 coefficient of friction tester GM-6
Coefficient of friction testers is used to test the coefficient of frictionof plastic film, thin sheet, paper and so on, widely used in packaging industry, film-making companies and packaging material inspection agencies.
Inclined Plane Friction Tester Inclined Surface Coefficient Of Friction Tester
GM-F1 Inclined Coefficient of Friction Tester is expert applicable to the resolve of stationary coefficients of paper board, friction of paper, sheets, plastic films, convey belts and additional substances. By challenging the frictional possessions of substances, the open presentation of packages, packing rapidity of packers and additional indexes could be regulated to meet necessities for production.Different functions from other coefficient friction testers  (cof)    
COF tester GM-4 Coefficient of Friction Tester
  The coefficient of friction tester GM-4 is a measuring instrument developed and manufactured by the Guangzhou Biaoji R&D team based on various test standards of GB, ISO, ASTM and market demand. The measured friction coefficient determines the smoothness and opening difficulty of the film. and uniformity can be accurately determined, so as to correctly guide the production. It is suitable for measuring the static friction coefficient, dynamic friction coefficient and peel strength of plastic films, composite films, aluminum foils, aluminized films, plates, rubber, ceramics and other materials when sliding.        
gas generator High purity nitrogen hydrogen and air gas generator for gas chromatography
gas generator can generates high purity nitrogen, hydrogen and air; it can supply stable and high quality gas for Gas Chromatography
water vapor transimission rate WVTR MVTR water vapor permeability analyzer electrolytic sensor method for flexible barrier sheet materials test - W201
Water vapor permeability analyzer is used to test water vapor transmission rate (WVTR) of films or sheets materials for flexible packaging.
Professional Battery Separator Air Permeability Tester supplier Battery Separator Air Permeability Tester
Product Brief The N600E Battery Separator Air Permeability Tester is designed and developed in accordance with standards such as GB/T 36363-2018. Adopting the differential pressure method as its testing principle, it is professionally used for testing the air permeability of battery separators, breathable films, and related polymer materials. Testing Principle In an environment with controlled temperature, humidity, and normal pressure, the tester measures the time required for 100 mL of air to pass through a 6.45 cm² separator under an applied pressure of 1.21 kPa. Executed Standards GB/T 36363-2018, ISO 5636-5:2003, TAPPI T460 Technical Parameters Item Technical Parameters Test Range 60~12000 sec/100mL Resolution 0.1 sec/100mL Pressure Range 0~5 kPa Pressure Resolution 0.001 kPa Test Area 6.45 cm² Sample Size >50 mm×50 mm Instrument Dimensions 450 mm×400 mm×300 mm Power 100 W Power Supply 110~250 VAC, 50~60 Hz Product Features • The instrument's differential pressure is adjustable within the range of 0~5 kPa, with a precision of 0.001 kPa, fully meeting the test pressure requirements of different methods;• Supports multi-unit display (s/100mL and μm/(Pa·s));• The test range can be customized according to different sample requirements;• Excellent airtightness;• Arbitrary pressure adjustment, fully automatic operation, and automatic measurement and calculation of results;• Equipped with a color touch screen, no external computer required, enabling real-time observation of sample air permeability;• Built-in micro-printer for real-time printing of test reports;• The upper computer software is designed in accordance with the new GMP Appendix "Computerized Systems", supporting functions such as hierarchical permission management, audit trail, and electronic signature (optional).
Vacuum Freeze Dryer Vacuum Freeze Dryer GB-LGJ-200F
Introduction Factory use vacuum freeze dryer is suitable for drying product such as food, drug products, biological products, Chinese medicine and more. It is to dry product at low temperature to preserve, stabilize, store and increase the life of products.. Freeze vacuum drying is a new type of box structure introduced by the vacuum freeze dryer that combines the refrigeration system, vacuum system, heat transfer oil heating system, and moisture removal system. It uses the space for storing materials in the box to dry. Main Technical Parameters   Item GB-LGJ-200F Drying chamber Freeze-drying area 2.25m2 Layers of shelf 5+1 Temperature scope of shelf -50℃-+70℃ (no-load) Shelf temperature error ±1℃ (in balance) Shelf spacing 70mm Size of shelf 500mm*900mm Condenser Min. Temperature of condenser ≤-70℃ (no-load) Water-capture capability >30Kg Liquid material 22L(thickness 10mm) Defrosting Electric defrosting Final Vacuum degree ≤ 5Pa Style of cooling Fan cooling Main functions Manual + Auto Control Mode, Sensor calibration, Intelligent temperature control, Freeze drying termination reminding and other functions are available.               Technical parameters □ Main configuration   Shelf effective area 2.25 m2 □ Specification   Shelf size 500mm × 900mm   Shelf numbers 5+1(Radiation layer) Top shelf as temperature compensating plate   Material number plate 10 pcs   Shelf spacing 70 mm   Shelf temperature range -50℃~+70℃ (no-load)   Min. condenser temp. ≤ -70℃  (no-load)   System final vacuum degree ≤ 5Pa □ Basic configuration    Installation Power 13.5KW     ★ This is installed power, not operating power. □ Shape and other parts   Dimension(mm): About 1200x2100x1700mm, L*W*H   Weight(Kg):  About 1200   Noise ≤ 80dB   Electrical system Ground protection   Design, production, installation standards According to GMP, GB/T522 6.1-1996   Whole machine test Test, verify data, methods, and equipment support □ Drying chamber components   Shape Rectangular   Roughness of inner wall Ra ≤ 0.6μm   Opening direction Clockwise or anticlockwise (overlooking ,user confirm)   Chamber material AISI 304  stainless steel ◆  Door  material ACRYLIC   Working temperature ≥ 70℃   Thermal insulation material Polyurethane foam □ Shelf components ◆ Shelf material AISI 304  Top and bottom plate thickness 5mm ◆ Shelf structure AISI 304 stainless steel (Patent No. :ZL201020237059.X)   Roughness of shelf Ra ≤ 0.6 μm   Flatness ≤ ±0.5mm / m   Effective shelf size 500mm×900 mm   Amount of shelf 5+1     Effective area of shelf 2.25m2 ◆ Shelf spacing  70 mm   Temperature decreasing rate +20℃ down to -40℃/ within 60 min, (no-load, entrance of silicon oil )   Temperature elevating rate -40℃ up to +20℃/ within 60 min, (no-load, entrance of silicon oil ) ◆ Shelf lowest temperature ≤ -50℃      (no-load, entrance of silicon oil )   Shelf highest temperature ≥ +70℃    (no-load, entrance of silicon oil )   Shelf temperature error ≤ ±1℃ ≤ ±1℃ ( in balance ) □ Condenser components   Condenser Shape Vertical type, cylindrical Compact structure, better water capture ,easy to clean and defrosting ◆ Condenser material AISI 304   Condenser water capture ≥ 30Kg   Condenser temp. Decreasing +20℃--40℃, within 30 minutes ◆   Condenser Min. temp. ≤ -70℃   Defrosting Electrochemical cream ◆ Thermal insulation material Polyurethane foam □ Refrigeration system   Refrigerator France original imported TECUMSEH full closure compressor ◆ Refrigerant Environmentally friendly refrigerant   Refrigerator number 2 sets   Shelf refrigeration 1 sets (shelf refrigeration at same time, indirect refrigeration)   Condenser refrigeration 1 set (shelf refrigeration at same time, direct refrigeration) ★ World famous devices are used to make sure correct, stable, safe and reliable.   High pressure protection device When system’s air discharge pressure exceeds allowed pressure, machine automatically stops working, to avoid an accident.   expansion valve DANFOSS(Denmark)   Top cover valve Castel(Italy)   solenoid valve DANFOSS(Denmark)   Oil separator ZOER   High pressure controller DANFOSS(Denmark)   Disacidify filter DANFOSS(Denmark)   Pressure meter LR/REFCO LR/REFCO(Germany/Swiss) oil submerge  pressure meter   Water cooling condenser Well-known brand □ Vacuum system ◆ Double stage rotary vane pump Tan's Vacuum Pump   Quantity 1 set ◆ Vacuum gauge Reborn   Chamber pumping rate Atmosphere→10 Pa ≤30 minutes(in dry condition)   System Maximum vacuum ≤ 5Pa   System leaking rate ≤ 10 Pa·l / sec □ Liquid circulation system ◆   Liquid low viscosity silicon oil ( 25℃, 5cst ) National qualified product   Liquid tubing material AISI 304, welding, heat  keeping ◆ Circulation pump ★GRUNDFOS, original imports, web rotor canned pump From Denmark brand, world famous brand   Circulation pump quantity 1 set   Heating rate 4kW   Heating control style Solid-state relay ◆ Stainless steel plate heat exchanger Well-known brands   Temperature sensor PT-100 platinum resistance □  Control system ◆ Control style Automatic and manual control ◆ Control system FD-PILOT   Control board SH-HPSC-II   Touch screen MCGS   Intermediate relay CHINT   AC contactor CHINT   Air circuit-breaker CHINT   Wiring terminals: Well-known brands □ Safety protection   Whole machine protection All safety conditions are ready for whole machine, machine can start running.   Operation protection Electrical system have logic interlock, control and protection function   Vacuum pressure Available   Heating system Available   Power cut and supply With safety protection measure   Products protection during sublimation process Heat cutting if vacuum lack   Condenser protection when vacuum pump start Interlock □ Whole machine design   Power 3Ph+N+PE, 380V   Installed power 13.5 KW (this is installed power, not running power)   Whole machine structure Integrated structure (easy for transport and placement)   Whole machine size About  1200x2100x1700mm, L*W*H   Whole machine weight (kg) About 1200   Time of warranty: One year after site acceptance.  
PCT test chamber PCT Test Chamber Pressure Cooker test chamber GB-OPCT-30
1.Function It’s widely used in rubber products, magnetic materials, circuit boards, muti-layer circuit boards, IC, LCD, electronics and other products sealing performance testing.   2.Characteristics 1) The imported double-temperature structure with high temperature resistant solenoid valve is used to minimize the failure rate. 2) Independent steam generation chamber to avoid direct impact of steam on the product, so as not to cause partial damage to the product. 3) The door lock labor-saving structure solves the shortcomings of the locking difficulty of the first-generation product disc handle. 4) Cool air before the test; the design of the exhaust air in the test (air discharge in the test barrel) improves the pressure stability and reproduction. 5) Ultra long-term experimental running time up to 400 hours. 6) Water level protection, through the test room water level Sensor to detect protection. 7) Tank with anti-pressure design, the box body with pressure (150 ° C) up to 2.65kg, in line with the water pressure test of 6kg. 8) Two-stage pressure safety protection device, adopting two-stage combined controller and mechanical pressure protection device. 9) Safety protection pressure button, two-stage automatic pressure button for emergency safety device. 10) Bias test terminal withstand voltage up to 3000V (optional) 11) USB for exporting the history data, curve. 3.Technical parameters 1)Temperature range: +100°C~+132°C (Saturated vapor temperature) 2)Humidity Range: 100% steam Humidity 3)Humidity Control Stability: ±1%RH 4)Working pressure: 1.2~2.89kg/cm2 (including 1atm) 5)Time Range: 0 Hr to 999 Hr 6)Pressurization time: 0.00 Kg ~ 1.04 Kg/cm2 about 45 minutes 4.Material of chamber 1)Test chamber size:∮300 mm x L500 mm; 2)Overall size: W900x D900 x H1400 mm; 3)Inner barrel material: Stainless steel plate material (SUS# 316, 3mm); 4)Outer barrel material: stainless steel plate material or spray plastic; 5)Insulation material: rock wool and hard polyurethane foam insulation 6)Steam chamber heating tube: Titanium tube is heated and never rusts. 7)Control System: Taiwan-made Delta color touch PLC to control humidity and steam temperature (using PT-100 Platinum temperature sensor). (Imported large-screen touch controller) 5.Mechanical structure 1)Round inner box, stainless steel round test inner box structure, in line with industrial safety container standards, can prevent dew condensation design during test. 2)Round lining, stainless steel circular lining design, can avoid direct impact of vapor latent heat on the sample. 3)Precision design, good air tightness, low water consumption, and can be operated continuously for 400Hrs every time. 4)The patented packing design makes the door and the box more tightly combined, which is completely different from the traditional extrusion type, and can extend the packing life. 5)Critical point LIMIT mode automatic safety protection, abnormal cause and fault indicator display. 6)Security Protection: a)Imported high temperature sealed solenoid valve adopts double circuit structure to ensure no leakage of pressure. b)The whole machine is equipped with over-pressure protection, over-temperature protection, one-button pressure relief, manual pressure relief and multiple safety guarantee devices to ensure users to the greatest extent. c)Use and safety. d)Back pressure door lock device, the test box door cannot be opened when there is pressure inside the test chamber. 6.Other accessories. 1)Test rack 1 group 2)Sample tray   7.Ambient environment & Facilities. 1)It can be allowed to use the working environment temperature 5 ° C ~ 30 ° C; experimental water: pure water or distilled water 2)System power fluctuations should not be greater than ± 10, 220V 20A.    
Automatic torque meters GBPI ASTM D3198 Automatic Torque Tester
The torque tester is professionally suitable for testing the torque value of the caps of packaging products such as bottles, beverage bottles, mineral water bottles, and milk bottles. It is an ideal configuration instrument for offline or online testing of production units in the packaging industry.
Residual Solvents Testing Flexographic Printing Residual Solvents in Packaging Materials
The identification and quantitation of residual printing solvents in synthetic packaging materials are very important for the material packaging suppliers, the printers and the packaging users of food and pharmaceutical products.
1 GBPI ASTM D 3078 hermetic sealing quality test electronic leakage tester GB-M1
GBPI Electronic Leakage Tester Application: To test the hermetic sealing quality and performance of packaging bags, bottles, cans and so on, used in industries of food, beverage, pharmaceuticals, personal care and so on.
Vacuum Decay Leak Detection Tester Dual Pressure Methods Vacuum Decay Leak Detection Tester AUTO GBM-L2
AUTO GBM‑L2 Dual‑Pressure Micro‑Leak Seal Tester: Micro‑Leakage Detection for Pharmaceutical & Food Packaging GBPI AUTO GBM‑L2 Dual‑Pressure Micro‑Leak Seal Tester for Packaging Micro‑Leak Detection Product Introduction AUTO GBM‑L2 Dual‑Pressure Methods Vacuum Decay Leak Detection Tester adopts the test principle of vacuum decay method/pressure decay to detect micro‑leakage of finished packaging. It can be applied to packaging systems composed of vials, ampoules, pre‑filled syringes, eye drop bottles, HDPE bottles, infusion bottles/bags and other pharmaceutical packaging, food packaging, and chemical industry packaging. Testing Principle The host is connected to a sealed test chamber customized according to the sample. When performing the vacuum decay method test, the instrument evacuates the test chamber, and a pressure difference is formed inside and outside the sample. Under the action of the pressure, the gas/liquid in the sample enters the test chamber through the leak hole. The main engine uses the absolute pressure sensor and the differential pressure sensor to monitor the pressure change in the chamber to judge whether the sample leaks. When performing the pressure decay method test, the instrument fills the test chamber with a predetermined air pressure, and the gas in the test chamber enters the sample through the leak hole. The host uses absolute pressure sensors and differential pressure sensors to monitor the pressure changes in the chamber to determine whether the sample is leaking. Executive Standards ASTM F2338‑2009(2013), YY‑T 0681.18‑2020, USP<1207.2>, ASTM F2095, supporting leakage verification for global pharmaceutical and food packaging regulatory requirements. Core Technical Parameters Absolute Pressure Testing Range (0‑300) kPa Differential Pressure Testing Range (-2‑2) kPa Detection Sensitivity 1‑3 μm Balancing / Testing Time 1‑3600 s Vacuum Purge Time 1‑3600 s Set Flow Rate 0‑3 mL/min Testing System Dual Sensor Technology / Dual Cycle Testing Testing Chamber Customized according to the sample Applicable Products Vials, Ampoules, Prefilled Syringes, Infusion Bottles/Bags, etc. Detection Principle Vacuum Decay Method / Pressure Decay Method Dimensions of the Main Unit 495 mm*455 mm*280 mm Ambient Temperature 20℃‑25℃ Relative Humidity 40%‑60% Working Power Supply AC 220V, 50HZ Product Features • Dual‑Pressure Methods, to help solve testing difficulties. The double combination of vacuum decay method and pressure decay method solves the problem of easy misjudgment and false negative for freeze‑dried powder injections containing vacuum in the bottle using a single vacuum decay method. Based on dual‑sensor and dual‑circulation system technology, high‑quality absolute pressure sensor and differential pressure sensor, with an accuracy of 0.1% FS, can effectively detect large and small leaks, accurately calculate the leak hole diameter, and give a pass or fail judgment. • Low detection sensitivity and good test repeatability. For rigid samples, the detection sensitivity is as low as 1 μm, and the test repeatability is as low as 0.8%. The instrument has stable performance, low noise and good repeatability. • Imported brand accessories, excellent performance. Imported brand vacuum pump, pumping rate up to 3 L/s, noise as low as 50 DB, high ultimate vacuum, convenient oil level detection and replacement. The imported gas mass flow controller can simulate micro‑leaks arbitrarily, with a resolution of 0.001 mL/min, which provides a reliable guarantee for the method verification of instrument sensitivity. • Large‑size touch screen, intelligent operation. Color 7‑inch touch screen, clear view, sensitive touch, easy to operate. Equipped with a micro‑printer, USB data interface, and supports PC software measurement and control operation. The test software is designed according to the GMP appendix "Computerized System". It has an audit trail function and multi‑level authority settings for users, which can meet the needs of the pharmaceutical industry for data traceability. • Personalized customization to meet the needs of different samples. For different test samples, it supports customization of suitable test chambers to meet the needs of different tests. For the same type of samples, it supports customized nesting mode, which can realize the sharing of a test chamber for samples of various specifications. Application Fields Freeze‑dried powder injection Injection Prefill needle Eye drops Plastic Ampoule BFS Infusion bags Factory Configuration Standard Host machine, vacuum pump, test chamber and 3 sets of yin and yang control (customized as required), 11‑inch touch panel, professional software (GMP) Optional Imported gas flow meters, air compressors, printers, calibration certificates Conclusion AUTO GBM‑L2 dual‑pressure micro‑leak seal tester combines vacuum‑decay and pressure‑decay technology, solving false‑negative defects existing in single‑mode leak detection for vacuum‑containing pharmaceutical containers. With imported core components, audit‑trail data function and customizable test chamber, it is ideal micro‑leakage inspection equipment for pharmaceutical factories, third‑party testing laboratories and R&D institutions for parenteral preparation packaging quality control. Get Quotation for This Unit GBPI Packaging Test Equipment ManufacturerAddress: No.3 Linjiang Road, Xiagang Subdistrict, Huangpu District, Guangzhou, Guangdong, ChinaTel: +86 15820231129 | Official Website: www.gbpitester.com
  • Facebook
  • Linkedin
  • Youtube
  • Twitter

Copyright @ 2026 Guangzhou Biaoji Packaging Equipment Co.,Ltd. All Rights Reserved.

Chat now

Inquiry Now

Home

Products

NEWS