The coefficient of friction tester is used to test the coefficient of frictionof plastic film, thin sheet, paper and so on, widely used in packaging industry, film-making companies and packaging material inspection agencies.

  • Brand:

    GBPI
  • Item NO.:

    GM-1
  • Payment:

    TT
  • Product Origin:

    China
  • Lead Time:

    around 7 working days
Inquiry now
Product Detail



Introduction

The coefficient of friction tester GM-1 is a measuring instrument developed and manufactured by the Guangzhou Biaoji R&D team based on various test standards of GB, ISO, ASTM and market demand. The measured friction coefficient determines the smoothness and opening difficulty of the film. and uniformity can be accurately determined, so as to correctly guide the production.

It is suitable for measuring the static friction coefficient, dynamic friction coefficient and peel strength of plastic films, composite films, aluminum foils, aluminized films, plates, rubber, ceramics and other materials when sliding.

Test Principle

Use a clamp to clamp the strip test sample, and wrap the slider with the sample to be tested, and then place the slider on the hanging hole of the sensor. Under a certain contact pressure, the conveyor belt is driven by the motor to move the force sensor. , that is, to move the two test surfaces relative to each other. The force signal measured by the force sensor is amplified by the integrator and sent to the recorder, and the kinetic friction coefficient and the static friction coefficient are recorded respectively.

 

 

Standard

GB 10006、ISO 8295、TAPPI T816

Specification

Item

Technical parameter

COF test range

0.001~0.999

Resolution

0.001

Measurement accuracy

±0.5FS

Force range

0~9.8 N

Sliding speed

100150500 mm/min

Stroke

100 mm±5 mm

Sample thickness

≤2 mm

Slider size

63 mm×63 mm

Slider Weight

200 g±2 g

Work platform size

200 mm×470 mm

Instrument size

470 mm×350 mm×220 mm

Power

100 W

Power supply

AC 220 V50 Hz

Weight

12.5 kg

 

 

Feature

 Instrument is stable, reliable and easy to maintain

 Intelligent operating system

 Laboratory intelligent Iot platform  


Application

 

 

Film

Suitable for static friction coefficient and dynamic friction coefficient test of plastic film and thin film  

 

Paper

 Suitable for dynamic and static friction coefficient test of paper and cardboard

 

 

Textiles, non-woven fabrics, woven bags

 

Suitable for testing static friction coefficient and dynamic friction coefficient of textile, non-woven fabric and woven bag

 

Aluminum foil, aluminum foil composite film, metal products

 

Suitable for testing static friction coefficient and dynamic friction coefficient of aluminum foil, aluminum foil composite film and metal products  

 

Printing product

It is suitable for static friction coefficient and dynamic friction coefficient test of printed matter



Send A Message

Leave us a message, we will get back to you ASAP.

Related Products
coefficient of friction tester New advanced 0.01~0.999 film packaging COF GM-6 coefficient of friction tester GM-6
Coefficient of friction testers is used to test the coefficient of frictionof plastic film, thin sheet, paper and so on, widely used in packaging industry, film-making companies and packaging material inspection agencies.
Inclined Plane Friction Tester Inclined Surface Coefficient Of Friction Tester
GM-F1 Inclined Coefficient of Friction Tester is expert applicable to the resolve of stationary coefficients of paper board, friction of paper, sheets, plastic films, convey belts and additional substances. By challenging the frictional possessions of substances, the open presentation of packages, packing rapidity of packers and additional indexes could be regulated to meet necessities for production.Different functions from other coefficient friction testers  (cof)    
COF tester GM-4 Coefficient of Friction Tester
  The coefficient of friction tester GM-4 is a measuring instrument developed and manufactured by the Guangzhou Biaoji R&D team based on various test standards of GB, ISO, ASTM and market demand. The measured friction coefficient determines the smoothness and opening difficulty of the film. and uniformity can be accurately determined, so as to correctly guide the production. It is suitable for measuring the static friction coefficient, dynamic friction coefficient and peel strength of plastic films, composite films, aluminum foils, aluminized films, plates, rubber, ceramics and other materials when sliding.        
Electronic Tensile Tester Electronic Digital Tensile Tester Machine GBL-H2
  GBL-H2 Universal Single Column Electronic Tensile Tester Product Introduction Developed by R&D team of Guangzhou Biaoji Packaging Equipment Co., Ltd., GBL-H2 universal single column electronic tensile tester complies with GB, ASTM and other relevant standards and market demands. Equipped with high-precision sensors, it features high force measurement accuracy, stable loading and long service life. The LCD screen with professional software displays real-time test curves and data, and supports test report query for easy operation. With fully automatic control unit, it is equipped with complete safety protection functions including limit protection, overload protection and emergency stop. This tester is used for tensile, peeling, heat seal, tearing, puncture and other mechanical property tests of metallic and non-metallic materials. It meets the technical requirements of national supervision departments, and is widely applied in quality control of plastic film, food and pharmaceutical enterprises, as well as scientific research and teaching experiments of testing institutions and schools. Test Principle Fix the prepared specimen between two clamps. Start the instrument to make the two clamps move relatively. The force sensor on the moving clamp collects force changes during the test, and the built-in displacement sensor records displacement changes. Finally, the mechanical indicators such as tensile strength, peeling strength, heat seal performance and tearing strength of the specimen are calculated. Compliance Standards GB 8808, GB 13022, GB/T 1040, GB 4850, GB/T 7753, GB/T 7754, GB/T 453, GB/T 17200, GB/T 16578.1, QB/T 1130, GB/T 2791, GB/T 2790, GB/T 2792, GB/T 7122, GB/T 10004, GB/T 17590, JJG 139, GB/T 6344, GB 10808, YBB 00112003, YBB 00102003, YBB 00132002, YBB 00202004, ASTM D828, ASTM E4, ASTM D882, ASTM D1938, ASTM D3330, ASTM F904, JIS P8113, QB/T 2358 Technical Parameters Force Measuring Range 0~300 N (Optional: 0~500 N) Force Measuring Accuracy Within ±0.5 %FS (Class 0.5) Test Speed 0~500 mm/min (Stepless speed regulation) Displacement Accuracy Within ±0.5% Effective Test Width 30 mm (Customizable: 50 mm, 60 mm) Effective Test Stroke 750 mm (Customizable: 1000 mm, 1200 mm) Overall Dimension L×W×H:600 mm×500 mm×1300 mm Weight 65 kg Power Supply AC 220 V,50 Hz Product Features Elegant and portable desktop single-column structure, comfortable for sitting operation. Supports tensile, peeling, heat seal, tearing, puncture and other tests; multiple adjustable parameters. High sampling rate (100 times/second) ensures accurate test data. Three-level safety protection with emergency stop switch. Adopts imported core components for high precision and long service life. LCD screen displays real-time data and working status. Intelligent operating system supports user management, authority management and audit trail, complying with GMP computerized system requirements. It can work independently or connect with computer for online testing, and the built-in printer outputs data in real time. Optional laboratory intelligent IoT platform, realizing data management and remote fault diagnosis.
Headspace Gas Analyzer Headspace Gas Analyzer-GB-DK
Product Introduction The headspace gas analyzer adopts the destructive puncture detection method and is equipped with high-precision oxygen sensors and carbon dioxide sensors to accurately detect the O2 and CO2 content of hollow packaging containers such as packaging bags, bottles, cans, etc. The analysis of the content of the headspace gas in the packaging can make a reasonable judgment on the product quality, the validity of the shelf life prediction, and the rationality of the packaging design. At the same time, it can also be used as a means of packaging tightness testing. It is a better choice for modified atmosphere preservation (MAP, CAP) packaging, large infusion bottles (bags), residual oxygen in the headspace of prefilled needles, residual oxygen detection in vials, and the results of residual oxygen detection for various food and medicines. Nowadays, the headspace gas analyzer has become an important method to check the quality of packaging design and one of the important methods to verify the product shelf life. Our headspace gas analyzer GB-DK can quickly detect O2 in production lines, warehouses, laboratories and other occasions. And CO2 content to guide production.   Test principle The gas in the sample is drawn into the sensor by a vacuum pump. The sensor outputs the current and voltage signals of the O2 and CO2 (optional) concentration in the gas in the sample in real time. The instrument calculates the content of O2 and CO2 in the gas by obtaining the current and voltage signals output by the sensor. After reaching the end conditions of the experiment, the test stops, and the instrument records the concentration of O2 and CO2 in the measured gas in the sample.   Technical parameter Item Parameter Gas to be Measured O2 (standard configuration) CO2 (optional) Measurement Principle Fluorescence optics infrared absorption Measurement Range 0%~25% (for O2) 0%~100% (for CO2) Measurement Accuracy ±0.2% ±2% Sample Size ≥5 mL (at standard atmospheric pressure) (for O2) ≥20 mL (at standard atmospheric pressure) (for CO2) Dimensions 350 mm (L)×330 mm(W)×200 mm(H) Power Supply 220 VAC±10 % 50Hz/120 VAC±10 % 60 Hz Net Weight 5kg    Features 1.Using high-precision sensors, high accuracy, good stability, long-term operation, long service life. Over-range automatic protection function to avoid damage to important sensors when the instrument fails. 2.The needle/probe safety holster is used to ensure safe testing and fast sampling. 3.Oxygen and carbon dioxide can be detected at the same time, and carbon dioxide gas can be selected for analysis according to different user needs. The sampling volume is at least 3 ml. 4.Built-in operating system, the system is equipped with an ARM control system to control the host through a touch screen (testing equipment and control software are combined into one); at the same time, the system can be expanded, such as connecting to the laboratory LIMS system. 5.The software is designed according to the requirements of the computerized system in the new version of the GMP appendix, and users are divided into multiple levels such as operators and administrators (such as administrators, operators, observers, etc. but not limited to these levels). 6.It has the audit trail function, which can realize the audit trail of the system, project operation, and method to ensure the safety and integrity of the test data. 7.Personalize the test report, set the report module that needs to be displayed, and output the report in PDF mode. The micro printer can print test reports in real time.  
Oxygen Permeability Analyzer PE Film Oxygen Permeability Analyzer - Y310
Oxygen Permeability Analyzer Y310 is to test the oxygen transmission rate (OTR) of films or sheets materials. ...
Astm d1777 thickness tester for Fabric Astm d1777 thickness tester for Fabric digital thickness gauge of solid electrical insulation laboratory paper dial thickness test device
The thickness of the film material, an important characteristic of the packaging material, varies and is critical for other properties such as permeability, tensile strength, impact resistance, etc.
Water Vapour Permeation Analyzer Water Vapor Permeability Tester electrolytic sensor method -W203
W203 Water Vapor Permeability Tester Wholly automatic, software easy to use. Curves of transmission rate, water vapor density, humidity and temperature, auto record and continuous display. 
Thickness Tester Plastic Film Digital Thickness Tester
Didital thickness tester is used to make thickness measuring or comparative measuring of plastic film, thin sheet, paper and so on.
DSC Tester DSC100A DSC Testing Lab Differential Scanning Calorimeter
High Precision DSC Differential Scanning Calorimeter Product Introduction This DSC is our highest-precision differential scanning calorimeter. It is equipped with imported thermocouple sensors featuring ultra-high sensitivity. The signal acquisition circuit adopts full shielding protection design, delivering strong anti-interference capability and excellent baseline stability. Adopting touch screen operation, this instrument can perform glass transition temperature test, phase transition analysis, melting enthalpy measurement, product stability evaluation and oxidation induction period test, covering a wide range of testing applications. Test Principle By measuring the heat flow difference between the sample and the reference material under programmed temperature control, the instrument analyzes thermal characteristic parameters such as melting point, glass transition temperature and oxidation resistance of polymer, pharmaceutical and packaging materials. Technical Parameters Temperature Range Room Temperature ~ 550 ℃ (Air Cooling) Temperature Resolution 0.01℃ Temperature Fluctuation ±0.1℃ Temperature Repeatability ±0.1℃ Heating Rate 0.1~100℃/min Constant Temperature Duration Programmable ≤ 24h Temperature Control Modes Heating, Constant Temperature DSC Heat Flow Range 0~±600mW DSC Resolution 0.01μW DSC Accuracy 0.001mW Power Supply AC 220V, 50Hz (Customizable) Atmosphere Control Gas Nitrogen, Oxygen (Automatic Instrument Switching) Gas Flow Rate 0-300ml/min Gas Pressure 0.2MPa Display Screen 7-inch 24-bit Color LCD Touch Screen Data Interface Standard USB Port Calibration Standard Comes with Indium & Tin Reference Materials for User Self Temperature Calibration PC Software Compatibility 3-in-1 Host Software, Compatible with TGA & Synchronous Thermal Analyzers Thermocouple Configuration 3 Groups of Thermocouples: Sample Temp, Furnace Temp, Internal Ambient Temp Technical Features
Ozone Aging Test Chamber Ozone Aging Test Chamber (Dynamic Stretching) GB-OCY-150M
1 Function Ozone in the atmosphere is very little, while it’s a major factor in rubber cracking, the product simulate and enhance atmospheric ozone condition to study the role of ozone on the rubber, and to rapid identificate and evaluate rubber resistance for ozone aging and anti-ozone agent protection. According to“GB / T7762-2003 Test Method for Static Tensile Test of Ozone Resistance Cured Rubber or Thermoplastic Rubber”,“GB / T2951.21-2008 General Test Method for Insulation and Sheathing Material of Cable”,“GB / T 11206-2009 Rubber Aging test surface cracking method”, and other relevant standards of the test method. 2.1 Structure  All-in-one machine 2.2 Material a) Inner chamber: SUS304 stainless steel plate b) External chamber: SUS304 stainless steel plate or baking finish. Insulation: rigid polyurethane foam + aluminum insulation cotton with double protection. 2.3 Machine door a) Single door, open from left. b) Window frame / door frame with two silicone rubber seal and anti-condensation heating device. c)With observation window (W220xH250mm), lights above the window and door.  2.4 Requirements for sample holder (for dynamic-type only)       a)At both ends of the sample to be fixed with a clamp under the required elongation, the longitudinal direction of the specimen shall be substantially parallel to the direction of air flow when in contact with ozonized air. b) Clamps shall be made of a material (eg aluminum) which does not readily decompose ozone. c) Allow the sample to rotate at a speed between (20 ^ -25) mm / s, in a plane perpendicular to the dry gas flow, with each sample moving continuously along the same path. d) The time of one revolution of the same specimen is (8 ^ -12) min. The scanning area of the specimen shall be at least 40% of the effective area of the test chamber. Specimen preparation shall conform to the provisions of GB / T 9865.1. The test specimen is preferably cut from the new test piece and, if desired, may be cut from the finished product. At least 3 specimens shall be required for per test condition. The standard length of the specimen is not less than 10mm, and thickness not less than 0.2mm. The length of specimen between the two ends of the clamp before drawing is not less than 40mm. 3 Control panel a) Controller display b) Power switch c) Fault alarm d)Wavelength switch e)light switch button 4 Enclosure configuration a) With a stainless steel SUS # 304 shelf turntable b) One φ50mm lead hole:, and with a hole cover and silicone rubber plug. c) Move casters 4 pcs d) Horizontal mounting brackets 4 pcs e) There is a drainage hole in the back of the machine to facilitate the drainage of condensate; (8mm in diameter) Three-phase five-wire cable (four-core cable + protective grounding wire) 1 pc, (three meters long).
  • Facebook
  • Linkedin
  • Youtube
  • Twitter

Copyright @ 2026 Guangzhou Biaoji Packaging Equipment Co.,Ltd. All Rights Reserved.

Chat now

Inquiry Now

Home

Products

NEWS

contact