packaging testing equipment Water Vapor Permeation Tester
Products
Home /

Physical Property Test Equipment

/

Coefficient of Friction Tester

/GM-1 0-10N plastic film packaging coefficient of friction tester

GM-1 0-10N plastic film packaging coefficient of friction tester

The coefficient of friction tester is used to test the coefficient of frictionof plastic film, thin sheet, paper and so on, widely used in packaging industry, film-making companies and packaging material inspection agencies.

  • Brand:

    GBPI
  • Item NO.:

    GM-1
  • Payment:

    TT
  • Product Origin:

    China
  • Lead Time:

    around 7 working days
Inquiry now
Product Detail



Introduction

The coefficient of friction tester GM-1 is a measuring instrument developed and manufactured by the Guangzhou Biaoji R&D team based on various test standards of GB, ISO, ASTM and market demand. The measured friction coefficient determines the smoothness and opening difficulty of the film. and uniformity can be accurately determined, so as to correctly guide the production.

It is suitable for measuring the static friction coefficient, dynamic friction coefficient and peel strength of plastic films, composite films, aluminum foils, aluminized films, plates, rubber, ceramics and other materials when sliding.

Test Principle

Use a clamp to clamp the strip test sample, and wrap the slider with the sample to be tested, and then place the slider on the hanging hole of the sensor. Under a certain contact pressure, the conveyor belt is driven by the motor to move the force sensor. , that is, to move the two test surfaces relative to each other. The force signal measured by the force sensor is amplified by the integrator and sent to the recorder, and the kinetic friction coefficient and the static friction coefficient are recorded respectively.

 

 

Standard

GB 10006、ISO 8295、TAPPI T816

Specification

Item

Technical parameter

COF test range

0.001~0.999

Resolution

0.001

Measurement accuracy

±0.5FS

Force range

0~9.8 N

Sliding speed

100150500 mm/min

Stroke

100 mm±5 mm

Sample thickness

≤2 mm

Slider size

63 mm×63 mm

Slider Weight

200 g±2 g

Work platform size

200 mm×470 mm

Instrument size

470 mm×350 mm×220 mm

Power

100 W

Power supply

AC 220 V50 Hz

Weight

12.5 kg

 

 

Feature

 Instrument is stable, reliable and easy to maintain

 Intelligent operating system

 Laboratory intelligent Iot platform  


Application

 

 

Film

Suitable for static friction coefficient and dynamic friction coefficient test of plastic film and thin film  

 

Paper

 Suitable for dynamic and static friction coefficient test of paper and cardboard

 

 

Textiles, non-woven fabrics, woven bags

 

Suitable for testing static friction coefficient and dynamic friction coefficient of textile, non-woven fabric and woven bag

 

Aluminum foil, aluminum foil composite film, metal products

 

Suitable for testing static friction coefficient and dynamic friction coefficient of aluminum foil, aluminum foil composite film and metal products  

 

Printing product

It is suitable for static friction coefficient and dynamic friction coefficient test of printed matter



Send A Message

Leave us a message, we will get back to you ASAP.

Related Products
coefficient of friction tester New advanced 0.01~0.999 film packaging COF GM-6 coefficient of friction tester GM-6
Coefficient of friction testers is used to test the coefficient of frictionof plastic film, thin sheet, paper and so on, widely used in packaging industry, film-making companies and packaging material inspection agencies.
Inclined Plane Friction Tester Inclined Surface Coefficient Of Friction Tester
GM-F1 Inclined Coefficient of Friction Tester is expert applicable to the resolve of stationary coefficients of paper board, friction of paper, sheets, plastic films, convey belts and additional substances. By challenging the frictional possessions of substances, the open presentation of packages, packing rapidity of packers and additional indexes could be regulated to meet necessities for production.Different functions from other coefficient friction testers  (cof)    
COF tester GM-4 Coefficient of Friction Tester
  The coefficient of friction tester GM-4 is a measuring instrument developed and manufactured by the Guangzhou Biaoji R&D team based on various test standards of GB, ISO, ASTM and market demand. The measured friction coefficient determines the smoothness and opening difficulty of the film. and uniformity can be accurately determined, so as to correctly guide the production. It is suitable for measuring the static friction coefficient, dynamic friction coefficient and peel strength of plastic films, composite films, aluminum foils, aluminized films, plates, rubber, ceramics and other materials when sliding.        
Salt Spray Tester Salt spray test chamber GB-OSH-60
  1. FunFunction Salt spray test chamber is used for the quality inspection and corrosion resistance test of a variety of materials, including metal plating, metal, electronic components, chemical coatings, paint, automobiles, motorcycles, metal ware, screws, springs, magnetic materials, organic and inorganic coating, anodizing, anti-rust oil industry etc. after the surface treatment.   1. ecGTechnical parameters   1. MODEL GB-OSH-60 2. Temperature inside chamber 35℃±1℃/ 50℃±1℃ 3. Temperature of pressure barrel 47℃±1℃/ 63℃±1℃  4. Inner size W600 x H400 x D450mm   5. External size W1080 x H1080 x D650mm 6. Temperature Uniformity ≤±2℃ 7. Uniformity Fluctuation ≤±0.5℃ 8. Salt fog settlement 1~2ml/h.80cm2 9. Compressed air pressure 1.00±0.01kgf/cm² 10. Spray mode Continuous or intermittent spray optional 11. Power supply AC  220V   50Hz   1.5KW a)  Temp. range: RT+10℃ ~ 55℃ (temperature up to 50C, thickening PVC or PP material is recommended ) b) Humid. range: ≥93%R.H c) Controller time shown: 9.9s~9990hrs d) Timer: 0~9999hrs. e) Testing method: Neutral salt spray test (NSS test), acetic acid salt spray test (AASS test), salt spray test (SS test), copper accelerated acetic acid salt spray test method for salt spray test (CASS test) and so on; (For CASS test, we recommend the PP material chamber with high temperature resistance) f) Specimen holder: It can meet the tilt test at 15 ℃ ~ 30 ℃ (two layers); g) Air compressor: V-0.013/12.5(Customer provided); discharge pressure:1.25M; flow amount: 0.13m3/min   1. MMMaterial of machine body a) Salt spray chamber adopts the quality PVC reinforced hard plastic plate, the surface is smooth and anti-aging, anti-corrosion; b) Without any FRP material produced on the surface because of discoloration fibrosis. Plastic structure of the chamber is better to meet strong acid salt spray test under long-term without any damage. c) Cover is imported transparent impact-resistant plate which is convenient to test specimen when test, that can cover and the box with a water seal to prevent leakage of salt spray.   2. AccAccording to CSN, JIS, ASTM standards, can be set to constant temperature control: (a) Brine spray test: NSS (neutral); · Temp. inside chamber: 35 ℃ ± 1 ℃ · Pressure air bucket: 47 ℃ ± 1 ℃ (b) Corrosion resistance test: CASS (copper acceleration), AASS (acid) · Temp. inside chamber: 50 ° C ± 1 ° C · Pressure air bucket: 63 ℃ ± 1 ℃   3. Watwatering system. It adopts the auto watering system, supply water when lack of water. 4. HeaHeating system Test temperature inside the cabinets is heated humidification water jacket, the heater adopts advanced titanium protective tube, built-in nickel-chromium alloy infrared heater core. Heating up fast, uniform temperature distribution; and saves about one half of the power compared to FRP tank jacketed heating. 5. ExeExecutive standard GB/T 2423.17 Basic test procedures for electric and electronic products Ka"- salt spray test methods; GB/T 10125 Corrosion tests in artificial atmospheres – salt spray tests; ASTM B368 Test Method for Copper-Accelerated Acetic Acid-Salt Spray (Fog) Testing (CASS Test); JIS Z2371-2000 Methods of salt spray testing etc. ISO 9227 Corrosion tests in artificial atmospheres (Note: 2 collection device is required, bigger models than ZH-SH-90 (270L) is required; In some versions, it specifies over 400liters is necessary)  ASTM B117-18 Standard Practice for Operating Salt Spray (Fog) Apparatus (Note: 2 collection device is required, bigger models than ZH-SH-90 is required )  
Spout bag packaging machine Two-station Rotary Mode Spout Sealing Machine
Introduction   The fully automatic two-station turntable spout sealing machine is a machine specially used for automatic sleeve and heat sealing of spouts and pouches. It is suitable for spouts of various calibers, lengths and models. It is the preferred automation equipment for spout stand-up pouches for beverage packaging, suckable jellies, condiments and daily chemical products (laundry detergent, skin care products), etc. It can be customized to connect to the filling production line.   Specification Item Technical parameters Pouch type Stand-up pouch, three-side sealed pouch, accordion pouch, special-shaped pouch Material type Pouch: inner layer PE, inner layer PP Spout: PE, PP Product Specifications Pouch dimensions (center seal): 100~180 mm (length), 70~120 mm (width), seal length: 60~120 mm (slant seal): 135-180 mm (length), 70-100 mm (width), seal length: 60~120 mm Spout dimensions: 8.5 mm (standard), 10 mm, 14 mm, 16 mm, etc. Working speed Max80- 90 pcs/min Position accuracy ≤±0.5 mm Heat sealing system A total of 6 groups, including 1 preheating group, 4 heat sealing groups, and 1 cooling group Temperature control module 3 groups (8-channel modules), accuracy ±0.1℃ Heating temperature Room temperature ~300℃ Power supply 380V/50Hz   12KW Gas source 0.6~0.8MPa,600L/min Overall dimensions 3428 x 2525 x 2241mm (Length x Width x Height) Equipment weight 2400 Kg     Features l The sealing equipment features a two-station design, with fully automated operation of preheating, bagging, tube filling, and heat sealing processes.   l It utilizes PLC control and intelligent parameter setting, allowing for quick parameter adjustments based on different pouch types and spouts, simplifying operation.   l It employs imported temperature control modules and pneumatic components from SMC, Festo, and Airtac, ensuring reliable quality.   l It adopts a step-by-step heating and final cooling sealing process, resulting in excellent sealing performance.   l It features automatic fault detection, automatic alarm, automatic stop, and automatic fault diagnosis and display.   l The equipment is lightweight, occupies a small area, and boasts stable performance.   l All major components are made of aluminum alloy and stainless steel, meeting the environmental hygiene requirements of food and pharmaceutical GMP.    
Moisture vapor transmission rate WVTR MVTR Water Vapor Permeability Analyzer Cup Method W301
One test chamber water vapor permeability analyzer using weight reduction method is to test the water vapor transmission rate (WVTR) of films or sheets materials.
Professional SGW-810 Light Transmittance and Haze Tester Haze ASTM D1003 supplier SGW-810 Light Transmittance and Haze Tester Haze ASTM D1003
Application Use for test the light transmittance and haze degree of all transparent and semi-transparent parallel plane samples (plastic plate, sheets etc), and turbidity or clarity of liquid samples (water, drinks etc), used in the industries of plastics, membrane, coatings and paints, printing ink, research institute and so on.
Vacuum Decay Leak Detection Tester Dual Pressure Methods Vacuum Decay Leak Detection Tester AUTO GBM-L2
Introduction AUTO GBM-L2 Dual-Pressure Methods Vacuum Decay Leak Detection Tester adopts the test principle of vacuum decay method/pressure decay to detect micro-leakage of finished packaging. It can be applied to packaging systems composed of vials, ampoules, Leakage detection of pre-filled needles, eye drop bottles, HDPE bottles, infusion bottles/bags and other pharmaceutical packaging, food packaging, and chemical industry packaging.   Test principle The host is connected to a sealed test chamber customized according to the sample. When performing the vacuum decay method test, the instrument evacuates the test chamber, and a pressure difference is formed inside and outside the sample. Under the action of the pressure, the gas/liquid in the sample enters the test chamber through the leak hole. The main engine uses the absolute pressure sensor and the differential pressure sensor to monitor the pressure change in the chamber to judge whether the sample leaks. When performing the pressure decay method test, the instrument fills the test chamber with a predetermined air pressure, and the gas in the test chamber enters the sample through the leak hole. The host uses absolute pressure sensors and differential pressure sensors to monitor the pressure changes in the chamber to determine whether the sample is leaking.   Standard ASTM F2338-2009(2013),  YY-T 0681.18-2020,  USP<1207.2>, ASTM F2095   Specification Item Parameters Absolute Pressure Testing Range (0 - 300) kPa Differential Pressure Testing Range (-2 - 2) kPa Detection Sensitivity 1 - 3 μm Balancing/Testing Time 1 - 3600 s Vacuum Purge Time 1 - 3600 s Set Flow Rate 0 - 3 mL/min Testing System Dual Sensor Technology/Dual Cycle Testing Testing Chamber Customized according to the sample Applicable Products Vials, Ampoules, Prefilled Syringes, Infusion Bottles/Bags, etc. Detection Principle Vacuum Decay Method/Pressure Decay Method Dimensions of the Main Unit 495 mm455 mm280 mm Ambient Temperature 20℃ - 25℃ Relative Humidity 40% - 60% Working Power Supply AC 220V, 50HZ   Features u Dual-Pressure Methods, to help solve testing difficulties The double combination of vacuum decay method and pressure decay method solves the problem of easy misjudgment and false negative for freeze-dried powder injections containing vacuum in the bottle using a single vacuum decay method. Based on dual-sensor and dual-circulation system technology, high-quality absolute pressure sensor and differential pressure sensor, with an accuracy of 0.1% FS, can effectively detect large and small leaks, accurately calculate the leak hole diameter, and give a pass or fail judgment.   The instrument has low sensitivity and good test repeatability For rigid samples, the detection sensitivity is as low as 1 μm, and the test repeatability is as low as 0.8%. The instrument has stable performance, low noise and good repeatability. u Imported brand accessories, excellent performance Imported brand vacuum pump, pumping rate up to 3 L/s, noise as low as 50 DB, high ultimate vacuum, convenient oil level detection and replacement. The imported gas mass flow controller can simulate micro-leaks arbitrarily, with a resolution of 0.001 mL/min, which provides a reliable guarantee for the method verification of instrument sensitivity. u Large size touch screen, intelligent operation Color 7-inch touch screen, clear view, sensitive touch, easy to operate. Equipped with a micro-printer, USB data interface, and supports PC software measurement and control operation. The test software is designed according to the GMP appendix "Computerized System". It has an audit trail function and multi-level authority settings for users, which can meet the needs of the pharmaceutical industry for data traceability. u Personalized customization to meet the needs of different samples For different test samples, it supports customization of suitable test chambers to meet the needs of different tests. For the same type of samples, it supports customized nesting mode, which can realize the sharing of a test chamber for samples of various specifications.   Application       Freeze-dried powder injection Injection Prefill needle       Eye drops Plastic Ampoule BFS Infusion bags   Factory configuration Standard Host machine, vacuum pump, test chamber and 3 sets of yin and yang control (customized as required), 11-inch touch panel, professional software (GMP) Optional Imported gas flow meters, air compressors, printers, calibration certificates  
6 GBB-R2 Auto Melt Flow Indexer
Product introduction It is used to determine the MFR&MVR value of the melt flow rate through the standard die every 10 minutes when various plastics and gums pass through a certain temperature and load in a viscous flow state. It is suitble for melting high temperature polycarbonate, polysulfoxide, fluorine plastics, nylon and other engineering plastics. Also, it is appropriate for the polyformaldehyde, polystrene, polypropylene, ABS resin polyformaldehyde, polycarbonate resin and other low temperature plastic melting test. The machine is widely used in plastic production, plastic products, petrochemical and other industries as well as related universities, scientific research units and commodity inspection departments.
Water Vapor Permeability Analyzer Water Vapor Permeability Analyzer AUTO W809
Water Vapor Permeability Analyzer -AUTO W809 is designed and manufactured in accordance with ASTM E96, GB/T 1037 standards, and provides a wide range of high-efficiency water vapor transmission rate testing for low, medium and high water vapor barrier materials with the  principle of Gravimetric Method.
ST50 Spectrophotometer GBPI ST50 Spectrophotometer
Spectrophotometer ST50 is a spectrophotometer developed by GBPI series core technology, using built-in photodiode array (double 20 groups) sensors, imported whiteboard, while taking into account the measurement speed and convenience of operation. The repeatability delta E* AB of ST50 spectrophotometer is easily controlled within 0.03, and the Inter-instrument error delta E* AB is controlled within 0.2, to make the measurement more accurate. And the test data can be used for accurate color analysis and transmission in the laboratory. Application  Spectrophotometer ST50 is equipped with one customized measuring aperture, accurate color measurement and stable performance. It is used for accurate color measurement and quality control in plastic electronics, paint ink, textile and garment printing and dyeing, printing, ceramics and other industries, and can be used for fluorescent sample measurement.   Features  1. Large area photodiode array (dual 20 arrays) sensor  A larger area of double 20 array sensor, strong light saturation, weak light sensitivity and a wider spectrum response range, to ensure the instrument measurement speed, accuracy, stability and consistency, independent core technology, and international standards of the same platform, to achieve complete compatibility. 1. Adopt D/8 structure and SCI/SCE mode  Spectrophotometer ST50 uses a widely international use D/8 optical structure, SCI/SCE (Specular Component Included/Specular Component Excluded) synthesis technology, support SCI+SCE at the same time fast measurement, test time about 1.5 seconds.  2. Combination of full spectrum LED light source and UV light source The use of 400-700nm full spectrum LED light source ensures sufficient spectral distribution in the visible light range, avoiding the spectral loss of specific bands, strong light will not be saturated, weak light is more sensitive, and fluorescence samples can be easily measured. 4. Camera positioning can clearly observe the measured area  The ST50 spectrophotometer has built-in camera. Through the real-time scene-taking of the camera, it can accurately determine whether the measured part of the object is the target center, which improves the measurement efficiency and accuracy.
 Leak Test Equipment 2022 High Quality Machines Package Leak Test Equipment
Test Principle Firstly submerge the specimen in the water in the vacuum chamber, and then evacuate the vacuum chamber to form differential pressure between the inside and outside of specimen. The seal property can be obtained by observing the steady progression of bubbles from the specimen or observing how the specimen expands and restores to its original shape after vacuum release.
  • Facebook
  • Linkedin
  • Youtube
  • Twitter

Copyright @ 2026 Guangzhou Biaoji Packaging Equipment Co.,Ltd. All Rights Reserved.

Chat now

Inquiry Now

Home

Products

NEWS

contact