packaging testing equipment Water Vapor Permeation Tester
Products
Home /

Physical Property Test Equipment

/

Coefficient of Friction Tester

/GM-1 0-10N plastic film packaging coefficient of friction tester

GM-1 0-10N plastic film packaging coefficient of friction tester

The coefficient of friction tester is used to test the coefficient of frictionof plastic film, thin sheet, paper and so on, widely used in packaging industry, film-making companies and packaging material inspection agencies.

  • Brand:

    GBPI
  • Item NO.:

    GM-1
  • Payment:

    TT
  • Product Origin:

    China
  • Lead Time:

    around 7 working days
Inquiry now
Product Detail



Introduction

The coefficient of friction tester GM-1 is a measuring instrument developed and manufactured by the Guangzhou Biaoji R&D team based on various test standards of GB, ISO, ASTM and market demand. The measured friction coefficient determines the smoothness and opening difficulty of the film. and uniformity can be accurately determined, so as to correctly guide the production.

It is suitable for measuring the static friction coefficient, dynamic friction coefficient and peel strength of plastic films, composite films, aluminum foils, aluminized films, plates, rubber, ceramics and other materials when sliding.

Test Principle

Use a clamp to clamp the strip test sample, and wrap the slider with the sample to be tested, and then place the slider on the hanging hole of the sensor. Under a certain contact pressure, the conveyor belt is driven by the motor to move the force sensor. , that is, to move the two test surfaces relative to each other. The force signal measured by the force sensor is amplified by the integrator and sent to the recorder, and the kinetic friction coefficient and the static friction coefficient are recorded respectively.

 

 

Standard

GB 10006、ISO 8295、TAPPI T816

Specification

Item

Technical parameter

COF test range

0.001~0.999

Resolution

0.001

Measurement accuracy

±0.5FS

Force range

0~9.8 N

Sliding speed

100150500 mm/min

Stroke

100 mm±5 mm

Sample thickness

≤2 mm

Slider size

63 mm×63 mm

Slider Weight

200 g±2 g

Work platform size

200 mm×470 mm

Instrument size

470 mm×350 mm×220 mm

Power

100 W

Power supply

AC 220 V50 Hz

Weight

12.5 kg

 

 

Feature

 Instrument is stable, reliable and easy to maintain

 Intelligent operating system

 Laboratory intelligent Iot platform  


Application

 

 

Film

Suitable for static friction coefficient and dynamic friction coefficient test of plastic film and thin film  

 

Paper

 Suitable for dynamic and static friction coefficient test of paper and cardboard

 

 

Textiles, non-woven fabrics, woven bags

 

Suitable for testing static friction coefficient and dynamic friction coefficient of textile, non-woven fabric and woven bag

 

Aluminum foil, aluminum foil composite film, metal products

 

Suitable for testing static friction coefficient and dynamic friction coefficient of aluminum foil, aluminum foil composite film and metal products  

 

Printing product

It is suitable for static friction coefficient and dynamic friction coefficient test of printed matter



Send A Message

Leave us a message, we will get back to you ASAP.

Related Products
coefficient of friction tester New advanced 0.01~0.999 film packaging COF GM-6 coefficient of friction tester GM-6
Coefficient of friction testers is used to test the coefficient of frictionof plastic film, thin sheet, paper and so on, widely used in packaging industry, film-making companies and packaging material inspection agencies.
Inclined Plane Friction Tester Inclined Surface Coefficient Of Friction Tester
GM-F1 Inclined Coefficient of Friction Tester is expert applicable to the resolve of stationary coefficients of paper board, friction of paper, sheets, plastic films, convey belts and additional substances. By challenging the frictional possessions of substances, the open presentation of packages, packing rapidity of packers and additional indexes could be regulated to meet necessities for production.Different functions from other coefficient friction testers  (cof)    
COF tester GM-4 Coefficient of Friction Tester
  The coefficient of friction tester GM-4 is a measuring instrument developed and manufactured by the Guangzhou Biaoji R&D team based on various test standards of GB, ISO, ASTM and market demand. The measured friction coefficient determines the smoothness and opening difficulty of the film. and uniformity can be accurately determined, so as to correctly guide the production. It is suitable for measuring the static friction coefficient, dynamic friction coefficient and peel strength of plastic films, composite films, aluminum foils, aluminized films, plates, rubber, ceramics and other materials when sliding.        
Digital Thickness Meter Automatic High Precision Digital Thickness Meter
Automatic High Precision Digital Thickness Meter is a high precise thickness meter integrating optics, mechanology , electronics and algorithm. Easy to operate. Test results are displayed digitally. And can connect to computer for automatic control.
Electronic Tensile Tester Electronic Digital Tensile Tester Machine GBL-H
The popular single-guidance electronic tensile testing machine GBL-H is a mechanical property testing machine developed and manufactured by the Guangzhou Biaoji R&D team based on GB, JIS, ASTM and other standard requirements and market demands. The instrument adopts high-precision sensors, and the force measurement accuracy is within ±1 %FS; professional software support, fully automatic operation, equipped with liquid crystal display screen, real-time display of test curve data and query test report, convenient and fast testing; Choose built-in or external, with perfect limit protection, overload protection, emergency stop and other safety protection functions.
Salt Spray Tester Salt spray test chamber GB-OSH-60
  1. FunFunction Salt spray test chamber is used for the quality inspection and corrosion resistance test of a variety of materials, including metal plating, metal, electronic components, chemical coatings, paint, automobiles, motorcycles, metal ware, screws, springs, magnetic materials, organic and inorganic coating, anodizing, anti-rust oil industry etc. after the surface treatment.   1. ecGTechnical parameters   1. MODEL GB-OSH-60 2. Temperature inside chamber 35℃±1℃/ 50℃±1℃ 3. Temperature of pressure barrel 47℃±1℃/ 63℃±1℃  4. Inner size W600 x H400 x D450mm   5. External size W1080 x H1080 x D650mm 6. Temperature Uniformity ≤±2℃ 7. Uniformity Fluctuation ≤±0.5℃ 8. Salt fog settlement 1~2ml/h.80cm2 9. Compressed air pressure 1.00±0.01kgf/cm² 10. Spray mode Continuous or intermittent spray optional 11. Power supply AC  220V   50Hz   1.5KW a)  Temp. range: RT+10℃ ~ 55℃ (temperature up to 50C, thickening PVC or PP material is recommended ) b) Humid. range: ≥93%R.H c) Controller time shown: 9.9s~9990hrs d) Timer: 0~9999hrs. e) Testing method: Neutral salt spray test (NSS test), acetic acid salt spray test (AASS test), salt spray test (SS test), copper accelerated acetic acid salt spray test method for salt spray test (CASS test) and so on; (For CASS test, we recommend the PP material chamber with high temperature resistance) f) Specimen holder: It can meet the tilt test at 15 ℃ ~ 30 ℃ (two layers); g) Air compressor: V-0.013/12.5(Customer provided); discharge pressure:1.25M; flow amount: 0.13m3/min   1. MMMaterial of machine body a) Salt spray chamber adopts the quality PVC reinforced hard plastic plate, the surface is smooth and anti-aging, anti-corrosion; b) Without any FRP material produced on the surface because of discoloration fibrosis. Plastic structure of the chamber is better to meet strong acid salt spray test under long-term without any damage. c) Cover is imported transparent impact-resistant plate which is convenient to test specimen when test, that can cover and the box with a water seal to prevent leakage of salt spray.   2. AccAccording to CSN, JIS, ASTM standards, can be set to constant temperature control: (a) Brine spray test: NSS (neutral); · Temp. inside chamber: 35 ℃ ± 1 ℃ · Pressure air bucket: 47 ℃ ± 1 ℃ (b) Corrosion resistance test: CASS (copper acceleration), AASS (acid) · Temp. inside chamber: 50 ° C ± 1 ° C · Pressure air bucket: 63 ℃ ± 1 ℃   3. Watwatering system. It adopts the auto watering system, supply water when lack of water. 4. HeaHeating system Test temperature inside the cabinets is heated humidification water jacket, the heater adopts advanced titanium protective tube, built-in nickel-chromium alloy infrared heater core. Heating up fast, uniform temperature distribution; and saves about one half of the power compared to FRP tank jacketed heating. 5. ExeExecutive standard GB/T 2423.17 Basic test procedures for electric and electronic products Ka"- salt spray test methods; GB/T 10125 Corrosion tests in artificial atmospheres – salt spray tests; ASTM B368 Test Method for Copper-Accelerated Acetic Acid-Salt Spray (Fog) Testing (CASS Test); JIS Z2371-2000 Methods of salt spray testing etc. ISO 9227 Corrosion tests in artificial atmospheres (Note: 2 collection device is required, bigger models than ZH-SH-90 (270L) is required; In some versions, it specifies over 400liters is necessary)  ASTM B117-18 Standard Practice for Operating Salt Spray (Fog) Apparatus (Note: 2 collection device is required, bigger models than ZH-SH-90 is required )  
COF Testing Flexible Packaging Film Coefficient of Friction Tester COF Testing
The Coefficient of Friction Tester equipment performs tests to most of the recognised international test standards including IS0 8295 and ASTM 1894-78.
Gas Permeability Analyzer N530 L Gas Permeability Analyzer
Introduction Based on the test principle of the differential pressure method, N530L is designed with reference to the GB/T 1038 standard and used to test the gas transmission rate (quantity) of film or sheet materials.
Moisture vapor transmission rate GBPI WVTR Moisture Vapor Transmission Rate Tester
    W201 2.0 Water Vapor Transmission Rate Tester Product Introduction This product is developed, designed and manufactured based on the electrolytic test principle, in accordance with GB/T 21529, ISO15106-3 and other standards. It is used to test the water vapor transmission rate of samples under set temperature and humidity conditions. Suitable for water vapor transmission performance testing of high-barrier materials used in LCD display devices, solar cells, chip packaging, pharmaceuticals, food and other fields. Get a Free Quote Today   Test Principle W201 2.0 Water Vapor Transmission Rate Tester adopts the electrolytic method principle. The pre-processed sample is fixed in the middle of the test chamber, dividing the chamber into high-humidity and low-humidity sides. Humidified nitrogen flows on one side of the film, and dry nitrogen (carrier gas) flows at a fixed rate on the other side. Due to the humidity gradient, water vapor permeates from the high-humidity side to the low-humidity side. The water vapor passing through the sample is carried by the flowing dry nitrogen to the electrolytic sensor, and parameters such as the water vapor transmission rate of the sample are obtained through the electrical signal output by the sensor. Electrolytic Method Working Principle Diagram:             Executive Standards 2025 Edition Chinese Pharmacopoeia <4010 Determination Method of Water Vapor Transmission Rate of Pharmaceutical Packaging Materials>, GB/T 21529-2008, ISO15106-3, DIN 53122-2, YBB00092003-2015, ASTM F3299, JIS K7129-3   Technical Parameters Test Range 0.001~40g/(m²·24h) (Film & Sheet) Resolution 0.0001g/(m²·24h) (Film & Sheet) Temp. Control Range 15~45℃ Temp. Control Accuracy ±0.1℃ Humidity Control Range (5~90)%RH Humidity Control Accuracy ±1%RH Permeation Area 50.24 cm² Sample Size Φ100 mm Sample Thickness ≤3 mm Test Quantity 1 piece Carrier Gas 99.999% Nitrogen (User Provided) Carrier Pressure ≥0.1 MPa Carrier Flow 0~100 mL/min Gas Interface 1/8 inch Metal Tube Dimensions 380×620×385mm Weight 25kg Power 450 W Power Supply AC 220 V, 50 Hz   Product Features Core Technology & Upgraded Operation: High sensitivity, precision and stability of the sensor, capable of testing high-barrier materials in electronics, photovoltaic, solar, display and other fields. Brand new pneumatic control system, automatic fixture locks sample with one key, convenient and labor-saving, with excellent sealing performance. Precise Temperature & Humidity Control: Temperature: Bi-directional automatic control via semiconductor cooling plate, accuracy ±0.1℃. Humidity: Dual-airflow (dry & wet) humidity control method, stable and high precision, accuracy ±1%RH. Strong Expandability: With optional accessories, it can test water vapor transmission rate of packages and containers. Excellent Appearance & Real-time Visual Curve: Built-in 11.6-inch high-resolution color touch screen, clear view, sensitive touch. Fully automatic operation, one-key test, automatic judgment and shutdown. Real-time display of 5 groups of curves (permeation rate-time, temp-time, humidity-time, concentration-time), with preview/hide function. Intelligent OS & Global Certification: Self-developed intelligent OS, modular interface, flexible parameter setting. Designed in accordance with GMP Computerized System, with audit trail and multi-level user authority, meeting pharmaceutical industry data traceability requirements. Customizable test reports, multiple data output formats, electronic signature and online report approval. Professional Calibration & Reliable Data: Our company possesses the National Standard Material Classification Certificate for water vapor transmission rate approved by the State Administration of Quality Supervision, Inspection and Quarantine (GBW(E)130543 / GBW(E)130544). Self-developed national standard materials are used for instrument calibration, ensuring accurate, universal and authoritative test data.   Application Fields Packages & Containers Custom fixtures for pharmaceutical BFS, ointment tubes, infusion tubes. Chip Packaging Materials FR-4, BT resin, PI, ABF film, Al₂O₃ ceramic, metal substrate testing. Solar Cell Barrier Materials Solar backsheet, butyl rubber, ALD Al₂O₃, POE, EVA film testing. Display Field Barrier Materials For LCD high-barrier materials such as epoxy resin film, SiNx passivation film, modified PET Other Materials Ultra-high barrier materials for pharmaceutical, food, daily chemical industries.   Why Choose Us ✓ Professional R&D & Manufacturing We have professional R&D team and complete production line, focusing on physical property testing instruments for more than 20 years, providing reliable and stable testing equipment for global customers. ✓ High Precision & Quality Certification Products comply with international standards, equipped with high-precision sensors and intelligent control system, with national standard material certification and authoritative qualification. ✓ Perfect After-sales & Technical Support Global after-sales service network, timely technical guidance, professional training and lifelong maintenance services to ensure worry-free use. Guangzhou GBPI Packaging Equipment Co., Ltd. | Professional Testing Instrument Manufacturer  
Vacuum Decay Leak Detection Tester Dual Pressure Methods Vacuum Decay Leak Detection Tester AUTO GBM-L2
AUTO GBM‑L2 Dual‑Pressure Micro‑Leak Seal Tester: Micro‑Leakage Detection for Pharmaceutical & Food Packaging GBPI AUTO GBM‑L2 Dual‑Pressure Micro‑Leak Seal Tester for Packaging Micro‑Leak Detection Product Introduction AUTO GBM‑L2 Dual‑Pressure Methods Vacuum Decay Leak Detection Tester adopts the test principle of vacuum decay method/pressure decay to detect micro‑leakage of finished packaging. It can be applied to packaging systems composed of vials, ampoules, pre‑filled syringes, eye drop bottles, HDPE bottles, infusion bottles/bags and other pharmaceutical packaging, food packaging, and chemical industry packaging. Testing Principle The host is connected to a sealed test chamber customized according to the sample. When performing the vacuum decay method test, the instrument evacuates the test chamber, and a pressure difference is formed inside and outside the sample. Under the action of the pressure, the gas/liquid in the sample enters the test chamber through the leak hole. The main engine uses the absolute pressure sensor and the differential pressure sensor to monitor the pressure change in the chamber to judge whether the sample leaks. When performing the pressure decay method test, the instrument fills the test chamber with a predetermined air pressure, and the gas in the test chamber enters the sample through the leak hole. The host uses absolute pressure sensors and differential pressure sensors to monitor the pressure changes in the chamber to determine whether the sample is leaking. Executive Standards ASTM F2338‑2009(2013), YY‑T 0681.18‑2020, USP<1207.2>, ASTM F2095, supporting leakage verification for global pharmaceutical and food packaging regulatory requirements. Core Technical Parameters Absolute Pressure Testing Range (0‑300) kPa Differential Pressure Testing Range (-2‑2) kPa Detection Sensitivity 1‑3 μm Balancing / Testing Time 1‑3600 s Vacuum Purge Time 1‑3600 s Set Flow Rate 0‑3 mL/min Testing System Dual Sensor Technology / Dual Cycle Testing Testing Chamber Customized according to the sample Applicable Products Vials, Ampoules, Prefilled Syringes, Infusion Bottles/Bags, etc. Detection Principle Vacuum Decay Method / Pressure Decay Method Dimensions of the Main Unit 495 mm*455 mm*280 mm Ambient Temperature 20℃‑25℃ Relative Humidity 40%‑60% Working Power Supply AC 220V, 50HZ Product Features • Dual‑Pressure Methods, to help solve testing difficulties. The double combination of vacuum decay method and pressure decay method solves the problem of easy misjudgment and false negative for freeze‑dried powder injections containing vacuum in the bottle using a single vacuum decay method. Based on dual‑sensor and dual‑circulation system technology, high‑quality absolute pressure sensor and differential pressure sensor, with an accuracy of 0.1% FS, can effectively detect large and small leaks, accurately calculate the leak hole diameter, and give a pass or fail judgment. • Low detection sensitivity and good test repeatability. For rigid samples, the detection sensitivity is as low as 1 μm, and the test repeatability is as low as 0.8%. The instrument has stable performance, low noise and good repeatability. • Imported brand accessories, excellent performance. Imported brand vacuum pump, pumping rate up to 3 L/s, noise as low as 50 DB, high ultimate vacuum, convenient oil level detection and replacement. The imported gas mass flow controller can simulate micro‑leaks arbitrarily, with a resolution of 0.001 mL/min, which provides a reliable guarantee for the method verification of instrument sensitivity. • Large‑size touch screen, intelligent operation. Color 7‑inch touch screen, clear view, sensitive touch, easy to operate. Equipped with a micro‑printer, USB data interface, and supports PC software measurement and control operation. The test software is designed according to the GMP appendix "Computerized System". It has an audit trail function and multi‑level authority settings for users, which can meet the needs of the pharmaceutical industry for data traceability. • Personalized customization to meet the needs of different samples. For different test samples, it supports customization of suitable test chambers to meet the needs of different tests. For the same type of samples, it supports customized nesting mode, which can realize the sharing of a test chamber for samples of various specifications. Application Fields Freeze‑dried powder injection Injection Prefill needle Eye drops Plastic Ampoule BFS Infusion bags Factory Configuration Standard Host machine, vacuum pump, test chamber and 3 sets of yin and yang control (customized as required), 11‑inch touch panel, professional software (GMP) Optional Imported gas flow meters, air compressors, printers, calibration certificates Conclusion AUTO GBM‑L2 dual‑pressure micro‑leak seal tester combines vacuum‑decay and pressure‑decay technology, solving false‑negative defects existing in single‑mode leak detection for vacuum‑containing pharmaceutical containers. With imported core components, audit‑trail data function and customizable test chamber, it is ideal micro‑leakage inspection equipment for pharmaceutical factories, third‑party testing laboratories and R&D institutions for parenteral preparation packaging quality control. Get Quotation for This Unit GBPI Packaging Test Equipment ManufacturerAddress: No.3 Linjiang Road, Xiagang Subdistrict, Huangpu District, Guangzhou, Guangdong, ChinaTel: +86 15820231129 | Official Website: www.gbpitester.com
migration testing in food packaging Full-Automatic Overall Migration Tester -AUTO ZF1200
Full-Automatic Overall Migration Tester AUTO ZF1200 has an integrated system design of water bath evaporation, heating and drying, drying and cooling, and constant temperature weighing. It is suitable for testing the total migration (non-volatile matter, evaporation residue) and other items in the fields of purified water, pharmaceutical packaging materials, food packaging, cigarette tipping paper and chemical reagents. It can also be applied to the water content, loss on drying and other items of solid samples, and the total dissolved solids content test in water quality testing.
Film Pendulum Impact Tester Pendulum Impact Tester-GBG-L2
  Introduction Designed and manufactured according tostandards likeGB/T 8809、ASTM D3420, GBG-L2 Pendulum Impact Tester is suitable for determining pendulum impact resistance of the film materials,composite film,metallic foil and so on. The machine can be used in scientific research, teaching, industrial and mining enterprises, laboratory, research institute and quality supervision department.  
  • Facebook
  • Linkedin
  • Youtube
  • Twitter

Copyright @ 2026 Guangzhou Biaoji Packaging Equipment Co.,Ltd. All Rights Reserved.

Chat now

Inquiry Now

Home

Products

NEWS

contact