- Plastic Packaging Cutting Device for Impact or Tensile Test LC-2Product Description The LC-2 Sample Cutter is used for cutting samples of various plastic films, paper and other materials prior to stretching, peeling and heat sealing tests. It is easy and efficient to operate and can accurately cut samples of standard required sizes. Features Meets the sample making requirements for Type 2 specimens of standard GB/T 1040.3. Using imported tungsten steel finely ground special blades, sharp and durable, with hardness up to 92 HRA. Accurate sample size, no damage, smooth and burr-free edges. Spring tensioned for easy sample fixing and smooth sample cutting. The ability to cut up to 12 samples in a single pass allows for efficient production of large batches of samples. Safety protection, the outer layer of the blade is covered with an aricotta stopper so that the blade does not come into direct contact with it. Different sample widths can be ordered to suit the requirements of each customer. Specifications Item Specifications Cut size 15 mm×210 mm(Optional width) Number of samples 12 pcs(Single Layer) Sample thickness ≤ 200 μm Product size 250 mm×350 mm×248 mm Weight 11 kg
- Sample Cutter
- Rotary blade cutting machine
- Plastic Packaging Cutting Device for Impact or Tensile Test
Tags :
- UV lamp aging test chamber GB-OUVA-115Accelerated weathering tests are performed on materials by simulating ultraviolet radiation and condensation in natural sunlight to obtain results on material weathering resistance. It can simulate environmental conditions such as ultraviolet, rain, high temperature, high humidity, condensation, and darkness in natural climates. By reproducing these conditions, it can be combined into a cycle and allowed to automatically complete the cycle as required.View More
- Salt spray test chamber GB-OSH-601. FunFunction Salt spray test chamber is used for the quality inspection and corrosion resistance test of a variety of materials, including metal plating, metal, electronic components, chemical coatings, paint, automobiles, motorcycles, metal ware, screws, springs, magnetic materials, organic and inorganic coating, anodizing, anti-rust oil industry etc. after the surface treatment. 1. ecGTechnical parameters 1. MODEL GB-OSH-60 2. Temperature inside chamber 35℃±1℃/ 50℃±1℃ 3. Temperature of pressure barrel 47℃±1℃/ 63℃±1℃ 4. Inner size W600 x H400 x D450mm 5. External size W1080 x H1080 x D650mm 6. Temperature Uniformity ≤±2℃ 7. Uniformity Fluctuation ≤±0.5℃ 8. Salt fog settlement 1~2ml/h.80cm2 9. Compressed air pressure 1.00±0.01kgf/cm² 10. Spray mode Continuous or intermittent spray optional 11. Power supply AC 220V 50Hz 1.5KW a) Temp. range: RT+10℃ ~ 55℃ (temperature up to 50C, thickening PVC or PP material is recommended ) b) Humid. range: ≥93%R.H c) Controller time shown: 9.9s~9990hrs d) Timer: 0~9999hrs. e) Testing method: Neutral salt spray test (NSS test), acetic acid salt spray test (AASS test), salt spray test (SS test), copper accelerated acetic acid salt spray test method for salt spray test (CASS test) and so on; (For CASS test, we recommend the PP material chamber with high temperature resistance) f) Specimen holder: It can meet the tilt test at 15 ℃ ~ 30 ℃ (two layers); g) Air compressor: V-0.013/12.5(Customer provided); discharge pressure:1.25M; flow amount: 0.13m3/min 1. MMMaterial of machine body a) Salt spray chamber adopts the quality PVC reinforced hard plastic plate, the surface is smooth and anti-aging, anti-corrosion; b) Without any FRP material produced on the surface because of discoloration fibrosis. Plastic structure of the chamber is better to meet strong acid salt spray test under long-term without any damage. c) Cover is imported transparent impact-resistant plate which is convenient to test specimen when test, that can cover and the box with a water seal to prevent leakage of salt spray. 2. AccAccording to CSN, JIS, ASTM standards, can be set to constant temperature control: (a) Brine spray test: NSS (neutral); · Temp. inside chamber: 35 ℃ ± 1 ℃ · Pressure air bucket: 47 ℃ ± 1 ℃ (b) Corrosion resistance test: CASS (copper acceleration), AASS (acid) · Temp. inside chamber: 50 ° C ± 1 ° C · Pressure air bucket: 63 ℃ ± 1 ℃ 3. Watwatering system. It adopts the auto watering system, supply water when lack of water. 4. HeaHeating system Test temperature inside the cabinets is heated humidification water jacket, the heater adopts advanced titanium protective tube, built-in nickel-chromium alloy infrared heater core. Heating up fast, uniform temperature distribution; and saves about one half of the power compared to FRP tank jacketed heating. 5. ExeExecutive standard GB/T 2423.17 Basic test procedures for electric and electronic products Ka"- salt spray test methods; GB/T 10125 Corrosion tests in artificial atmospheres – salt spray tests; ASTM B368 Test Method for Copper-Accelerated Acetic Acid-Salt Spray (Fog) Testing (CASS Test); JIS Z2371-2000 Methods of salt spray testing etc. ISO 9227 Corrosion tests in artificial atmospheres (Note: 2 collection device is required, bigger models than ZH-SH-90 (270L) is required; In some versions, it specifies over 400liters is necessary) ASTM B117-18 Standard Practice for Operating Salt Spray (Fog) Apparatus (Note: 2 collection device is required, bigger models than ZH-SH-90 is required )View More
- PCT Test Chamber / Pressure Cooker test chamber GB-OPCT-301.Function It’s widely used in rubber products, magnetic materials, circuit boards, muti-layer circuit boards, IC, LCD, electronics and other products sealing performance testing. 2.Characteristics 1) The imported double-temperature structure with high temperature resistant solenoid valve is used to minimize the failure rate. 2) Independent steam generation chamber to avoid direct impact of steam on the product, so as not to cause partial damage to the product. 3) The door lock labor-saving structure solves the shortcomings of the locking difficulty of the first-generation product disc handle. 4) Cool air before the test; the design of the exhaust air in the test (air discharge in the test barrel) improves the pressure stability and reproduction. 5) Ultra long-term experimental running time up to 400 hours. 6) Water level protection, through the test room water level Sensor to detect protection. 7) Tank with anti-pressure design, the box body with pressure (150 ° C) up to 2.65kg, in line with the water pressure test of 6kg. 8) Two-stage pressure safety protection device, adopting two-stage combined controller and mechanical pressure protection device. 9) Safety protection pressure button, two-stage automatic pressure button for emergency safety device. 10) Bias test terminal withstand voltage up to 3000V (optional) 11) USB for exporting the history data, curve. 3.Technical parameters 1)Temperature range: +100°C~+132°C (Saturated vapor temperature) 2)Humidity Range: 100% steam Humidity 3)Humidity Control Stability: ±1%RH 4)Working pressure: 1.2~2.89kg/cm2 (including 1atm) 5)Time Range: 0 Hr to 999 Hr 6)Pressurization time: 0.00 Kg ~ 1.04 Kg/cm2 about 45 minutes 4.Material of chamber 1)Test chamber size:∮300 mm x L500 mm; 2)Overall size: W900x D900 x H1400 mm; 3)Inner barrel material: Stainless steel plate material (SUS# 316, 3mm); 4)Outer barrel material: stainless steel plate material or spray plastic; 5)Insulation material: rock wool and hard polyurethane foam insulation 6)Steam chamber heating tube: Titanium tube is heated and never rusts. 7)Control System: Taiwan-made Delta color touch PLC to control humidity and steam temperature (using PT-100 Platinum temperature sensor). (Imported large-screen touch controller) 5.Mechanical structure 1)Round inner box, stainless steel round test inner box structure, in line with industrial safety container standards, can prevent dew condensation design during test. 2)Round lining, stainless steel circular lining design, can avoid direct impact of vapor latent heat on the sample. 3)Precision design, good air tightness, low water consumption, and can be operated continuously for 400Hrs every time. 4)The patented packing design makes the door and the box more tightly combined, which is completely different from the traditional extrusion type, and can extend the packing life. 5)Critical point LIMIT mode automatic safety protection, abnormal cause and fault indicator display. 6)Security Protection: a)Imported high temperature sealed solenoid valve adopts double circuit structure to ensure no leakage of pressure. b)The whole machine is equipped with over-pressure protection, over-temperature protection, one-button pressure relief, manual pressure relief and multiple safety guarantee devices to ensure users to the greatest extent. c)Use and safety. d)Back pressure door lock device, the test box door cannot be opened when there is pressure inside the test chamber. 6.Other accessories. 1)Test rack 1 group 2)Sample tray 7.Ambient environment & Facilities. 1)It can be allowed to use the working environment temperature 5 ° C ~ 30 ° C; experimental water: pure water or distilled water 2)System power fluctuations should not be greater than ± 10, 220V 20A.View More
- Ozone Aging Test Chamber (Dynamic Stretching) GB-OCY-150M1 Function Ozone in the atmosphere is very little, while it’s a major factor in rubber cracking, the product simulate and enhance atmospheric ozone condition to study the role of ozone on the rubber, and to rapid identificate and evaluate rubber resistance for ozone aging and anti-ozone agent protection. According to“GB / T7762-2003 Test Method for Static Tensile Test of Ozone Resistance Cured Rubber or Thermoplastic Rubber”,“GB / T2951.21-2008 General Test Method for Insulation and Sheathing Material of Cable”,“GB / T 11206-2009 Rubber Aging test surface cracking method”, and other relevant standards of the test method. 2.1 Structure All-in-one machine 2.2 Material a) Inner chamber: SUS304 stainless steel plate b) External chamber: SUS304 stainless steel plate or baking finish. Insulation: rigid polyurethane foam + aluminum insulation cotton with double protection. 2.3 Machine door a) Single door, open from left. b) Window frame / door frame with two silicone rubber seal and anti-condensation heating device. c)With observation window (W220xH250mm), lights above the window and door. 2.4 Requirements for sample holder (for dynamic-type only) a)At both ends of the sample to be fixed with a clamp under the required elongation, the longitudinal direction of the specimen shall be substantially parallel to the direction of air flow when in contact with ozonized air. b) Clamps shall be made of a material (eg aluminum) which does not readily decompose ozone. c) Allow the sample to rotate at a speed between (20 ^ -25) mm / s, in a plane perpendicular to the dry gas flow, with each sample moving continuously along the same path. d) The time of one revolution of the same specimen is (8 ^ -12) min. The scanning area of the specimen shall be at least 40% of the effective area of the test chamber. Specimen preparation shall conform to the provisions of GB / T 9865.1. The test specimen is preferably cut from the new test piece and, if desired, may be cut from the finished product. At least 3 specimens shall be required for per test condition. The standard length of the specimen is not less than 10mm, and thickness not less than 0.2mm. The length of specimen between the two ends of the clamp before drawing is not less than 40mm. 3 Control panel a) Controller display b) Power switch c) Fault alarm d)Wavelength switch e)light switch button 4 Enclosure configuration a) With a stainless steel SUS # 304 shelf turntable b) One φ50mm lead hole:, and with a hole cover and silicone rubber plug. c) Move casters 4 pcs d) Horizontal mounting brackets 4 pcs e) There is a drainage hole in the back of the machine to facilitate the drainage of condensate; (8mm in diameter) Three-phase five-wire cable (four-core cable + protective grounding wire) 1 pc, (three meters long).View More
- Heat Seal Tester-GBB-F1GBB-F1 Heat Seal Tester is to test the temperature, pressure, and time for heat sealing of various film materials. It is applied to quality inspection organizations, drug control institutions, research institutes, packaging, thin film, food companies, pharmaceutical enterprises, personal care industry and so on.
- ASTM F2029 Heat Sealability Test
- Laboratory Heat Seal Tester
- Heat Sealability Test for Flexible Barrier Materials
Tags :