packaging testing equipment Water Vapor Permeation Tester
products
Home / Products
  • Professional Paper & Paperboard Air Permeability Tester supplier
    Paper & Paperboard Air Permeability Tester
    Product Brief The N600P Paper & Paperboard Air Permeability Tester is custom-developed to align with standards like GB/T 458-2008 and ISO 5636. It adopts the differential pressure method as its core testing principle, and innovatively integrates three industry-common testing approaches (Gurley, Schopper, and Bendtsen) into a single device.   This tester is applicable to air permeability detection of various paper and paperboard materials, and can measure key indicators including: material air permeability, air resistance, gas transmission rate, and total gas transmission volume. Testing Principle Gurley Method   Under a constant differential pressure of 1.23 kPa, measure the time required for 100 mL of gas to pass through the sample. Schopper Method   Select a suitable test duration under a constant differential pressure (1.00 kPa±0.01 kPa or 2.50±0.01 kPa), and calculate the gas flow rate through the sample by measuring the gas volume. Bendtsen Method   After clamping the sample for 5 seconds under a constant differential pressure of 1.47 kPa, test the gas flow rate through the surface of the sample. Executed Standards GB/T 458-2008, SJ/T 10171-2016, ISO 5636-5:2003, ISO 5636-2:1984, ISO 5636-3:2013, TAPPI T460 Technical Parameters   Item Technical Parameters Test Range 0.1~10 μm/(Pa·s) Resolution 0.001 μm/(Pa·s) Differential Pressure Range 0~5 kPa Pressure Resolution 0.001 kPa Test Area 6.42 cm² or 10.0 cm² Sample Size >50 mm×50 mm Instrument Dimensions (L×W×H) 450 mm×400 mm×300 mm Power 100 W Power Supply 110~250 VAC, 50~60 Hz
    View More
  • Professional Battery Separator Air Permeability Tester supplier
    Battery Separator Air Permeability Tester
    Product Brief The N600E Battery Separator Air Permeability Tester is designed and developed in accordance with standards such as GB/T 36363-2018. Adopting the differential pressure method as its testing principle, it is professionally used for testing the air permeability of battery separators, breathable films, and related polymer materials. Testing Principle In an environment with controlled temperature, humidity, and normal pressure, the tester measures the time required for 100 mL of air to pass through a 6.45 cm² separator under an applied pressure of 1.21 kPa. Executed Standards GB/T 36363-2018, ISO 5636-5:2003, TAPPI T460 Technical Parameters Item Technical Parameters Test Range 60~12000 sec/100mL Resolution 0.1 sec/100mL Pressure Range 0~5 kPa Pressure Resolution 0.001 kPa Test Area 6.45 cm² Sample Size >50 mm×50 mm Instrument Dimensions 450 mm×400 mm×300 mm Power 100 W Power Supply 110~250 VAC, 50~60 Hz Product Features • The instrument's differential pressure is adjustable within the range of 0~5 kPa, with a precision of 0.001 kPa, fully meeting the test pressure requirements of different methods;• Supports multi-unit display (s/100mL and μm/(Pa·s));• The test range can be customized according to different sample requirements;• Excellent airtightness;• Arbitrary pressure adjustment, fully automatic operation, and automatic measurement and calculation of results;• Equipped with a color touch screen, no external computer required, enabling real-time observation of sample air permeability;• Built-in micro-printer for real-time printing of test reports;• The upper computer software is designed in accordance with the new GMP Appendix "Computerized Systems", supporting functions such as hierarchical permission management, audit trail, and electronic signature (optional).
    View More
  • Professional Carbon Paper Air Permeability Rate Tester supplier
    Carbon Paper Air Permeability Rate Tester
    Product Brief The N600C Carbon Paper Air Permeability Rate Tester is designed and developed in accordance with GB/T 20042.7-2014. Adopting the differential pressure method as its testing principle, it is professionally used for measuring the air permeability rate of various types of carbon paper for proton exchange membrane fuel cells (PEMFC). Testing Principle Based on the differential pressure method, the sample is placed between two fixtures, forming a constant differential pressure on both sides of the sample. Driven by the differential pressure, gas flows from the high-pressure side through the sample to the low-pressure side. The air permeability rate of the carbon paper is calculated based on the transmission flow rate, sample thickness, test area, and test differential pressure. Executed Standards GB/T 20042.7-2014 Technical Parameters Item Technical Parameters Test Range 0~200,000 mL·mm/(cm²·h·mmHg)0~14,701 mL·mm/(cm²·hr·mmAq) Resolution 0.1 mL·mm/(cm²·h·mmHg)0.1 mL·mm/(cm²·hr·mmAq) Pressure Range 0~500 Pa (other ranges available upon request) Pressure Resolution 0.1 Pa Pressure Accuracy 0.1% FS (Full Scale) Flow Range 0~50 L/min (other ranges available upon request) Flow Resolution 1 mL/min Flow Accuracy 1% FS (Full Scale) Test Area 16 cm² Instrument Dimensions 410 mm×295 mm×365 mm Power 100 W Power Supply 110~250 VAC, 50~60 Hz Product Features • The instrument's differential pressure is adjustable within the range of 0~500 Pa, with an accuracy of 0.1% FS, fully meeting the test pressure requirements of different samples;• The test range can be customized according to different sample requirements;• Arbitrary pressure adjustment, fully automatic operation, and automatic measurement and calculation of results;• Equipped with a color touch screen, no external computer required;• Built-in micro-printer for real-time printing of test reports;• The upper computer software is designed in accordance with the new GMP Appendix "Computerized Systems", supporting functions such as hierarchical permission management, audit trail, and electronic signature (optional).  
    View More
  • Differential Pressure Gas Transmission Tester
    Differential Pressure Method Gas Transmission Tester N530A 2.0
    Introduction The N530A 2.0 Gas Permeability Tester is designed and manufactured based on the differential pressure testing principle, in accordance with standards such as GB/T 1038 and ISO 2556. It adopts a high-precision pressure sensor and automatic pressure difference maintenance technology, ensuring high testing accuracy. It is suitable for testing the gas permeability of films, sheets, paper, packaging materials and related products in fields including food, pharmaceuticals, medical devices, daily chemicals, and photovoltaic electronics. It provides wide-range and high-efficiency gas permeability detection for high, medium, and low gas barrier materials.
    View More
  • Gas permeation testing
    Laboratory Gas Permeability Testing Equipment
    Product Introduction The N500A 2.0 Gas Permeability Tester is a high - precision experimental testing equipment that integrates machinery, electronics, and software. It is suitable for testing the gas barrier properties of plastic films, composite films, sheets, metal foils, etc., as well as the gas permeability testing of packaging containers such as plastic, rubber, paper - based bottles, bags, cans, and boxes.  
    View More
  • Heat Seal Tester
    GBB-A3 Lid Film Heat Sealer
      GBB-A3 Heat Sealing Tester Product Introduction GBB-A3 heat sealing tester accurately measures heat sealing temperature, time, pressure and other performance parameters of lid films for jelly cups, yogurt cups, coffee capsules, instant noodle buckets, meal boxes, medical blister packs and other food & pharmaceutical packages. Optimal sealing conditions can be confirmed precisely by testing sealing properties of different materials. Testing Principle Install matched fixture on the lower support plate and place sample steadily. Set sealing temperature, time and pressure as required, then start the device. The upper fixture descends to complete sealing. In manual mode, step on foot switch to press sealing cutter with fixed sealing duration. In automatic mode, upper and lower cutters perform cyclic sealing automatically according to preset parameters. Compliance Standards QB/T 2358-1998, ASTM F 2029, YBB00122003-2015 Technical Parameters Temperature Range Room temperature ~ 250℃ Temperature Accuracy ±1℃ Sealing Time 0.1s ~ 99.99h Sealing Pressure 0~1 MPa Operation Mode Manual & Automatic Air Source Compressed air Overall Dimension 730×400×535 mm Weight 45 kg Power 1200 W Power Supply AC 220V, 50Hz Product Features Pull-out Loading Design Double-layer lower plate enables pull-out feeding, keeping away from sealing cutter for safe and convenient operation. High-precision Temperature Sensor PID temperature control ensures accuracy up to ±1℃, featuring excellent stability and low failure rate. Dual Optional Test Modes Automatic mode realizes repetitive fast sealing; manual mode equipped with foot switch for simple and safe operation. New Pneumatic Driving System Composed of pressure gauge, regulating valve and cylinder, air pressure can be precisely adjusted for efficient sealing. Customized Service Available Custom fixtures fit various cup sizes. Anti-stick sealing cutter and customizable shape, size & smoothness meet diverse research demands. Application Fields Jelly Cup Yogurt Cup Coffee Capsule Medical Blister Pack
    View More
first page 1 2 3 4 5 6 7 8 9 10 last page

A total of 27 pages

Contact Us

Call Us : +86 15820231129

Email Us : info@gbtest.cn

Address : No. 3 Linjiang Road, Huangpu District, Guangzhou, China

Send A Message

Leave us a message, we will get back to you ASAP.

  • Facebook
  • Linkedin
  • Youtube
  • Twitter

Copyright @ 2026 Guangzhou Biaoji Packaging Equipment Co.,Ltd. All Rights Reserved.

Chat now

Inquiry Now

Home

Products

NEWS

contact