- Dual Pressure Methods Vacuum Decay Leak Detection Tester AUTO GBM-L2Introduction AUTO GBM-L2 Dual-Pressure Methods Vacuum Decay Leak Detection Tester adopts the test principle of vacuum decay method/pressure decay to detect micro-leakage of finished packaging. It can be applied to packaging systems composed of vials, ampoules, Leakage detection of pre-filled needles, eye drop bottles, HDPE bottles, infusion bottles/bags and other pharmaceutical packaging, food packaging, and chemical industry packaging. Test principle The host is connected to a sealed test chamber customized according to the sample. When performing the vacuum decay method test, the instrument evacuates the test chamber, and a pressure difference is formed inside and outside the sample. Under the action of the pressure, the gas/liquid in the sample enters the test chamber through the leak hole. The main engine uses the absolute pressure sensor and the differential pressure sensor to monitor the pressure change in the chamber to judge whether the sample leaks. When performing the pressure decay method test, the instrument fills the test chamber with a predetermined air pressure, and the gas in the test chamber enters the sample through the leak hole. The host uses absolute pressure sensors and differential pressure sensors to monitor the pressure changes in the chamber to determine whether the sample is leaking. Standard ASTM F2338-2009(2013), YY-T 0681.18-2020, USP<1207.2>, ASTM F2095 Specification Item Parameters Absolute Pressure Testing Range (0 - 300) kPa Differential Pressure Testing Range (-2 - 2) kPa Detection Sensitivity 1 - 3 μm Balancing/Testing Time 1 - 3600 s Vacuum Purge Time 1 - 3600 s Set Flow Rate 0 - 3 mL/min Testing System Dual Sensor Technology/Dual Cycle Testing Testing Chamber Customized according to the sample Applicable Products Vials, Ampoules, Prefilled Syringes, Infusion Bottles/Bags, etc. Detection Principle Vacuum Decay Method/Pressure Decay Method Dimensions of the Main Unit 495 mm455 mm280 mm Ambient Temperature 20℃ - 25℃ Relative Humidity 40% - 60% Working Power Supply AC 220V, 50HZ Features u Dual-Pressure Methods, to help solve testing difficulties The double combination of vacuum decay method and pressure decay method solves the problem of easy misjudgment and false negative for freeze-dried powder injections containing vacuum in the bottle using a single vacuum decay method. Based on dual-sensor and dual-circulation system technology, high-quality absolute pressure sensor and differential pressure sensor, with an accuracy of 0.1% FS, can effectively detect large and small leaks, accurately calculate the leak hole diameter, and give a pass or fail judgment. The instrument has low sensitivity and good test repeatability For rigid samples, the detection sensitivity is as low as 1 μm, and the test repeatability is as low as 0.8%. The instrument has stable performance, low noise and good repeatability. u Imported brand accessories, excellent performance Imported brand vacuum pump, pumping rate up to 3 L/s, noise as low as 50 DB, high ultimate vacuum, convenient oil level detection and replacement. The imported gas mass flow controller can simulate micro-leaks arbitrarily, with a resolution of 0.001 mL/min, which provides a reliable guarantee for the method verification of instrument sensitivity. u Large size touch screen, intelligent operation Color 7-inch touch screen, clear view, sensitive touch, easy to operate. Equipped with a micro-printer, USB data interface, and supports PC software measurement and control operation. The test software is designed according to the GMP appendix "Computerized System". It has an audit trail function and multi-level authority settings for users, which can meet the needs of the pharmaceutical industry for data traceability. u Personalized customization to meet the needs of different samples For different test samples, it supports customization of suitable test chambers to meet the needs of different tests. For the same type of samples, it supports customized nesting mode, which can realize the sharing of a test chamber for samples of various specifications. Application Freeze-dried powder injection Injection Prefill needle Eye drops Plastic Ampoule BFS Infusion bags Factory configuration Standard Host machine, vacuum pump, test chamber and 3 sets of yin and yang control (customized as required), 11-inch touch panel, professional software (GMP) Optional Imported gas flow meters, air compressors, printers, calibration certificatesView More
- Falling ball impact tester GQ-D1GQ-D1 Drop Ball Impact Tester High Precision Impact Resistance Tester for Packaging PRODUCT PROFILE GQ-D1 Drop Ball Impact Tester is mainly used for testing the impact resistance of hard sheets for food packaging and solid pharmaceutical hard sheets. Traditional electromagnets generate high temperature and residual magnetism after power off, affecting accuracy. This instrument adopts the principle of electromagnetic repulsion, which can automatically release residual magnetism and avoid high temperature, ensuring experimental accuracy. It features high-precision control, intelligent operation and complete safety protection, widely applied in food and pharmaceutical packaging quality control. TEST PRINCIPLE Place the test product on the test bench. Let a steel ball of specified weight fall freely from a specified height to impact the product. Then check the product's appearance for damage and various performance indicators. COMPLIANCE STANDARDS GB/T 15267 YBB 0021-2005 YBB 00202005 YBB 00222005-2015 TECHNICAL PARAMETERS Item Parameter Impact Height 0~900 mm Steel Ball Φ23mm (50g), Φ25mm (60g), Φ28.6mm (100g), Φ38.1mm (225g) Clamping Range 120mm × 85mm Sample Size 150mm (L) × 50mm (W) Dimensions 325 × 550 × 1341mm Weight & Power 30kg, 75W, AC 220V 50Hz PRODUCT FEATURES Touch Screen Control Color touch screen for intuitive and easy operation. Anti-Residual Magnetism Electromagnetic repulsion principle, no residual magnetism or high temperature. Pneumatic Clamping Auto clamping/release reduces error and test time. Built-in Printer Instant test report printing and data query. Intelligent Test Intelligent testing process, greatly improve work efficiency. Accurate & Reliable Stable structure and accurate test results. APPLICATIONS Food Packaging Hard Sheets For PVC hard sheets in food packaging, quality control for food & packaging enterprises. Solid Pharmaceutical Hard Sheets For pharmaceutical hard sheets, quality control for pharmaceutical & packaging enterprises. © 2025 GBPI | GQ-D1 Drop Ball Impact Tester | Professional Testing SolutionView More
- GBL-L2 Plastic Film Tensile TesterThe GBL-L2 popular single-column electronic tensile tester is suitable for tensile, peeling, heat-sealing, tearing and other mechanical performance tests of various metal and non-metal materials. It meets the requirements of the national technical supervision department for test technology. It is widely used in plastic film, food, and pharmaceutical manufacturers to test products quality control and testing institutions, scientific research and teaching experiments in university.
- tensile tester
- plastic tensile tester
- plastic film tensile tester
- peel seal tester
- tensile/peel/seal strength/tear tester
Tags :
- Plastics Compost Biodegradation RespirometerGBDA-120 Compost Degradation Tester is designed in full compliance with standards such as ISO14855-1 and ASTM D5338. The mass of carbon dioxide released during biodegradation can be detected automatically, and the biodegradation percentage of degradable materials can be determined.
- Biodegradability Testing
- Compost Degradation Tester
- Bioplstic Test Equipment
- Biodegradation Respirometer
- Biodegradation Analyzer
Tags :
- Vacuum Freeze Dryer GB-LGJ-200FIntroduction Factory use vacuum freeze dryer is suitable for drying product such as food, drug products, biological products, Chinese medicine and more. It is to dry product at low temperature to preserve, stabilize, store and increase the life of products.. Freeze vacuum drying is a new type of box structure introduced by the vacuum freeze dryer that combines the refrigeration system, vacuum system, heat transfer oil heating system, and moisture removal system. It uses the space for storing materials in the box to dry. Main Technical Parameters Item GB-LGJ-200F Drying chamber Freeze-drying area 2.25m2 Layers of shelf 5+1 Temperature scope of shelf -50℃-+70℃ (no-load) Shelf temperature error ±1℃ (in balance) Shelf spacing 70mm Size of shelf 500mm*900mm Condenser Min. Temperature of condenser ≤-70℃ (no-load) Water-capture capability >30Kg Liquid material 22L(thickness 10mm) Defrosting Electric defrosting Final Vacuum degree ≤ 5Pa Style of cooling Fan cooling Main functions Manual + Auto Control Mode, Sensor calibration, Intelligent temperature control, Freeze drying termination reminding and other functions are available. Technical parameters □ Main configuration Shelf effective area 2.25 m2 □ Specification Shelf size 500mm × 900mm Shelf numbers 5+1(Radiation layer) Top shelf as temperature compensating plate Material number plate 10 pcs Shelf spacing 70 mm Shelf temperature range -50℃~+70℃ (no-load) Min. condenser temp. ≤ -70℃ (no-load) System final vacuum degree ≤ 5Pa □ Basic configuration Installation Power 13.5KW ★ This is installed power, not operating power. □ Shape and other parts Dimension(mm): About 1200x2100x1700mm, L*W*H Weight(Kg): About 1200 Noise ≤ 80dB Electrical system Ground protection Design, production, installation standards According to GMP, GB/T522 6.1-1996 Whole machine test Test, verify data, methods, and equipment support □ Drying chamber components Shape Rectangular Roughness of inner wall Ra ≤ 0.6μm Opening direction Clockwise or anticlockwise (overlooking ,user confirm) Chamber material AISI 304 stainless steel ◆ Door material ACRYLIC Working temperature ≥ 70℃ Thermal insulation material Polyurethane foam □ Shelf components ◆ Shelf material AISI 304 Top and bottom plate thickness 5mm ◆ Shelf structure AISI 304 stainless steel (Patent No. :ZL201020237059.X) Roughness of shelf Ra ≤ 0.6 μm Flatness ≤ ±0.5mm / m Effective shelf size 500mm×900 mm Amount of shelf 5+1 Effective area of shelf 2.25m2 ◆ Shelf spacing 70 mm Temperature decreasing rate +20℃ down to -40℃/ within 60 min, (no-load, entrance of silicon oil ) Temperature elevating rate -40℃ up to +20℃/ within 60 min, (no-load, entrance of silicon oil ) ◆ Shelf lowest temperature ≤ -50℃ (no-load, entrance of silicon oil ) Shelf highest temperature ≥ +70℃ (no-load, entrance of silicon oil ) Shelf temperature error ≤ ±1℃ ≤ ±1℃ ( in balance ) □ Condenser components Condenser Shape Vertical type, cylindrical Compact structure, better water capture ,easy to clean and defrosting ◆ Condenser material AISI 304 Condenser water capture ≥ 30Kg Condenser temp. Decreasing +20℃--40℃, within 30 minutes ◆ Condenser Min. temp. ≤ -70℃ Defrosting Electrochemical cream ◆ Thermal insulation material Polyurethane foam □ Refrigeration system Refrigerator France original imported TECUMSEH full closure compressor ◆ Refrigerant Environmentally friendly refrigerant Refrigerator number 2 sets Shelf refrigeration 1 sets (shelf refrigeration at same time, indirect refrigeration) Condenser refrigeration 1 set (shelf refrigeration at same time, direct refrigeration) ★ World famous devices are used to make sure correct, stable, safe and reliable. High pressure protection device When system’s air discharge pressure exceeds allowed pressure, machine automatically stops working, to avoid an accident. expansion valve DANFOSS(Denmark) Top cover valve Castel(Italy) solenoid valve DANFOSS(Denmark) Oil separator ZOER High pressure controller DANFOSS(Denmark) Disacidify filter DANFOSS(Denmark) Pressure meter LR/REFCO LR/REFCO(Germany/Swiss) oil submerge pressure meter Water cooling condenser Well-known brand □ Vacuum system ◆ Double stage rotary vane pump Tan's Vacuum Pump Quantity 1 set ◆ Vacuum gauge Reborn Chamber pumping rate Atmosphere→10 Pa ≤30 minutes(in dry condition) System Maximum vacuum ≤ 5Pa System leaking rate ≤ 10 Pa·l / sec □ Liquid circulation system ◆ Liquid low viscosity silicon oil ( 25℃, 5cst ) National qualified product Liquid tubing material AISI 304, welding, heat keeping ◆ Circulation pump ★GRUNDFOS, original imports, web rotor canned pump From Denmark brand, world famous brand Circulation pump quantity 1 set Heating rate 4kW Heating control style Solid-state relay ◆ Stainless steel plate heat exchanger Well-known brands Temperature sensor PT-100 platinum resistance □ Control system ◆ Control style Automatic and manual control ◆ Control system FD-PILOT Control board SH-HPSC-II Touch screen MCGS Intermediate relay CHINT AC contactor CHINT Air circuit-breaker CHINT Wiring terminals: Well-known brands □ Safety protection Whole machine protection All safety conditions are ready for whole machine, machine can start running. Operation protection Electrical system have logic interlock, control and protection function Vacuum pressure Available Heating system Available Power cut and supply With safety protection measure Products protection during sublimation process Heat cutting if vacuum lack Condenser protection when vacuum pump start Interlock □ Whole machine design Power 3Ph+N+PE, 380V Installed power 13.5 KW (this is installed power, not running power) Whole machine structure Integrated structure (easy for transport and placement) Whole machine size About 1200x2100x1700mm, L*W*H Whole machine weight (kg) About 1200 Time of warranty: One year after site acceptance.View More
- Temperature & Humidity Test Chamber OTH-150DJOTH-150DJ is used to test the performance of materials in various environments and test the heat resistance, cold resistance, dry resistance and humidity resistance of various materials. It is suitable for quality testing of products such as electronics, electrical appliances, mobile phones, communications, instruments, vehicles, plastic products, metals, food, chemicals, building materials, medical care, and aerospace.View More

info@gbtest.cn



en
ru
es
ar




